mgnt2TrapNodeControllerIpAddress
EKINOPS-MGNT2-MIB ·
.1.3.6.1.4.1.20044.7.3.58
Object
scalar
SNMPv2-SMIIpAddress
This OID gives the IP address of the Node Controller
Context
- MIB
- EKINOPS-MGNT2-MIB
- OID
.1.3.6.1.4.1.20044.7.3.58- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- mgnt2Traps
- Siblings
- 23
Syntax
SNMPv2-SMIIpAddress
- Source
- SNMPv2-SMIIpAddress
- Base type
OctetString
Values & Constraints
Type Constraints
range: 4
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mgnt2TrapApi Api error trap with its number | notification | - | .1.3.6.1.4.1.20044.7.3.1 |
| mgnt2TrapGigmPowerFail A power supply default has been detected in the management board | notification | - | .1.3.6.1.4.1.20044.7.3.10 |
| mgnt2TrapFanFail A Fan failure has been detected | notification | - | .1.3.6.1.4.1.20044.7.3.11 |
| mgnt2TrapSwError Chassis software error other API | notification | - | .1.3.6.1.4.1.20044.7.3.2 |
| mgnt2TrapLogFileFull Indicates that the corresponding log file is almost full | notification | - | .1.3.6.1.4.1.20044.7.3.20 |
| mgnt2TrapAlarm Indicates that an alarm state has changed | notification | - | .1.3.6.1.4.1.20044.7.3.30 |
| mgnt2TrapEvent Indicates that an event has occured | notification | - | .1.3.6.1.4.1.20044.7.3.31 |
| mgnt2TrapControl Indicates that a control has been set to the module | notification | - | .1.3.6.1.4.1.20044.7.3.32 |
| mgnt2TrapConfig Indicates that a config word has been changed | notification | - | .1.3.6.1.4.1.20044.7.3.33 |
| mgnt2TrapBoardInserted A board has been plugged in | notification | - | .1.3.6.1.4.1.20044.7.3.4 |
| mgnt2TrapBoardRemoved A board has been plugged out | notification | - | .1.3.6.1.4.1.20044.7.3.5 |
| mgnt2TrapBoardNumber This OID gives the slot number of the PM that sent the last trap | scalar | Integer32 | .1.3.6.1.4.1.20044.7.3.50 |
| mgnt2TrapSeverity This OID gives the trap severity | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.20044.7.3.51 |
| mgnt2TrapSourcePm This OID gives the mnemonic of the pm who sent a trap | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.20044.7.3.52 |
| mgnt2TrapSourcePortType This OID gives the type of the port who sent a trap | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.20044.7.3.53 |
| mgnt2TrapSourcePortNumber This OID gives the port number of the PM that sent the last trap | scalar | Integer32 | .1.3.6.1.4.1.20044.7.3.54 |
| mgnt2TrapSourceLabel This OID gives the label of the alarm who sent a trap | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.20044.7.3.55 |
| mgnt2TrapSourceValue This OID gives the value of the alarm who sent a trap | scalar | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.7.3.56 |
| mgnt2TrapEventLabel This OID gives the label of the event | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.20044.7.3.57 |
| mgnt2TrapChassisId This OID gives the chassis ID | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.20044.7.3.59 |
| mgnt2TrapRestoreConfDone The Configuration has been restored from the management board | notification | - | .1.3.6.1.4.1.20044.7.3.6 |
| mgnt2TrapGlobalPowerFail A global power supply failure has been detected | notification | - | .1.3.6.1.4.1.20044.7.3.8 |
| mgnt2TrapFanPowerFail A Fan power supply failure has been detected | notification | - | .1.3.6.1.4.1.20044.7.3.9 |