mgnt2AlmFifoCmdError
EKINOPS-MGNT2-MIB ·
.1.3.6.1.4.1.20044.7.2.1.32.2
Object
scalar
EKINOPS-MIBEkiOnOff
SNMP Agent to Transport comm FIFO fail :This OID indicates a failure inside the FIFO stack. The FIFO containing the messages from the agent (write) to the PMs is full <Help> This alarm indicates if there is a communication mismatch between the MGNT board and all PM <Condtype> FIFO_CMD_ERROR <Probcause> adapterError (2) <Alarmtype> equipmentAlarm (5) <Polarity> (2)
Context
- MIB
- EKINOPS-MGNT2-MIB
- OID
.1.3.6.1.4.1.20044.7.2.1.32.2- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- mgnt2AlmswAlarm1
- Siblings
- 2
Syntax
EKINOPS-MIBEkiOnOff
- Source
- EKINOPS-MIBEkiOnOff
- Base type
Enumeration
Values & Constraints
Type Values
1 | off |
2 | on |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| mgnt2AlmApiError Comm fail between Agent and Transport
:This OID indicates a failure detected
on the Agent.The failure is
located on a communication process
with the modules. <Help> Th… | scalar | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.7.2.1.32.1 |
| mgnt2AlmPollingManagerError Polling Manager fail :This OID
indicates a failure on the Manager
polling the PM's <Help>
<Help> This alarm indicates if
there is a polling manager failure
between th… | scalar | EKINOPS-MIBEkiOnOff | .1.3.6.1.4.1.20044.7.2.1.32.3 |