cableDiagResultStatusPairA

ECS4660-28F-MIB · .1.3.6.1.4.1.259.10.1.10.1.2.3.2.1.2

Object

column Enumeration
The result of cable diagnostics. If there is no fault
on the cable, the value is ok(2). Value notTestedYet(1)
means the pair is not tested yet. Value ok(2) means the
pair works well. Value open(3) means there is a lack of
continuity between pins at each end of the pair. Value
short(4) means conductors are short-circuited together on
the pair. Value openShort(5) means the pair has open
and short issues. Value crosstalk(6) means the pair is
incorrectly connected at one end. Value unknown(7) means
pair has an error matching none of the above. Value
impedanceMismatch(8) means different quality cables
connected together. Value failed(9) means test failed.
Value notSupported(10) means cable diagnostics is not
supported. Value noCable(11) means there is no connected
cable.

Context

MIB
ECS4660-28F-MIB
OID
.1.3.6.1.4.1.259.10.1.10.1.2.3.2.1.2
Type
column
Access
readonly
Status
current
Parent
cableDiagResultEntry
Table
cableDiagResultTable
Siblings
10

Syntax

Enumeration

Values & Constraints

Enumerated Values
1notTestedYet
2ok
3open
4short
5openShort
6crosstalk
7unknown
8impedanceMismatch
9failed
10notSupported
11noCable

Related Objects

Sibling Objects