ds1LOSDetected

ECI-TRAPS · .1.3.6.1.4.1.5395.4.1.9.1.0.16

Object

notification
This trap is only applicable to interfaces implementing
physical layer (electrical) DS1. The Loss Of Signal failure
is declared upon observing 175 +/- 75 contiguous pulse
positions with no pulses of either positive or negative
polarity. The LOS failure is cleared upon observing an average
pulse density of at least 12.5% over a period of 175 +/- 75
contiguous pulse positions starting with the receipt of a
pulse. (RFC1406)