docsPnmCmtsUsOfdmaAQProbeMaxCaptSymbols

DOCS-PNM-MIB · .1.3.6.1.4.1.4491.2.1.27.1.3.3.1.7

Object

column Unsigned32
This object represents the number of symbols the CMTS can capture for
one measurement. Typically for a 50kHz Subcarrier Spacing the CMTS can
capture two symbols and for 25kHz, the CMTS can capture one symbol. In
order to capture more than one symbol the CMTS would need to schedule
multiple probe opportunities for the CM whose probe is being measured.

Context

MIB
DOCS-PNM-MIB
OID
.1.3.6.1.4.1.4491.2.1.27.1.3.3.1.7
Type
column
Access
readonly
Status
current
Parent
docsPnmCmtsUsOfdmaAQProbeEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DOCS-PNM-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DOCS-PNM-MIB::docsPnmCmtsUsOfdmaAQProbeMaxCaptSymbols'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DOCS-PNM-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DOCS-PNM-MIB::docsPnmCmtsUsOfdmaAQProbeMaxCaptSymbols.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DOCS-PNM-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DOCS-PNM-MIB::docsPnmCmtsUsOfdmaAQProbeMaxCaptSymbols'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-65535

Conformance