docsPnmCmtsUsImpNoiseEndTrigLvl

DOCS-PNM-MIB · .1.3.6.1.4.1.4491.2.1.27.1.3.4.1.4

Object

column r/w microvolts SNMPv2-SMIUnsigned32
The measurement of an individual burst event ends when the burst noise
falls below the EndTriggerLevel. If the StartTriggerLevel is set to zero
then the EndTriggerLevel is not used and the measurement free runs for
the FreeRunDuration.
              
This object cannot be changed while a capture is in progress. It will
return a value of 'inconsistentValue' if set while the value of
'docsPnmCmtsUsImpNoiseMeasStatus' is set to a value of 'busy'.

Context

MIB
DOCS-PNM-MIB
OID
.1.3.6.1.4.1.4491.2.1.27.1.3.4.1.4
Type
column
Access
readwrite
Status
current
Units
microvolts
Parent
docsPnmCmtsUsImpNoiseEntry
Table
docsPnmCmtsUsImpNoiseTable
Siblings
11

Syntax

microvolts SNMPv2-SMIUnsigned32
Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects