docsPnmCmtsDsOfdmSymTrigGroupId

DOCS-PNM-MIB · .1.3.6.1.4.1.4491.2.1.27.1.3.1.1.2

Object

column r/w Unsigned32
This attribute is used by the CMTS to be inserted in the PLC Trigger
Message Block to identify a CM or a group of CMs expected to perform
Symbol Capture measurements for the designated symbol.
              
This value can only be changed while a test is not in progress. An attempt
to set this value while the value of 'docsPnmCmtsDsOfdmSymMeasStatus' is
'busy' will return 'inconsistentValue'.

Context

MIB
DOCS-PNM-MIB
OID
.1.3.6.1.4.1.4491.2.1.27.1.3.1.1.2
Type
column
Access
readwrite
Status
current
Parent
docsPnmCmtsDsOfdmSymCapEntry
Table
docsPnmCmtsDsOfdmSymCapTable
Siblings
10

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects

Sibling Objects