stpBridgeMaxAge
DLINK-DXS-1210-12TC-AX-MIB ·
.1.3.6.1.4.1.171.10.139.1.1.4.3.1.6
Object
scalar r/w
Integer32
The value that all bridges use for MaxAge when this bridge is acting as the root. The granularity of this timer is specified to be 1 second. An agent may return a badValue error if a set is attempted to a value which is not a whole number of seconds.
Context
- MIB
- DLINK-DXS-1210-12TC-AX-MIB
- OID
.1.3.6.1.4.1.171.10.139.1.1.4.3.1.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- stpProtocolSetting
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DLINK-DXS-1210-12TC-AX-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DLINK-DXS-1210-12TC-AX-MIB::stpBridgeMaxAge.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DLINK-DXS-1210-12TC-AX-MIB' -M '/opt/observium/mibs/d-link:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DLINK-DXS-1210-12TC-AX-MIB::stpBridgeMaxAge'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 600-4000