bfdReqMinRxInterval

DC-BFD-STUB-MIB · .1.3.6.1.4.1.629.10.11.1.1.1.7

Object

column r/w microseconds BfdInterval
This object specifies the default minimum interval (in
microseconds) between received BFD control packets
that the local system will advertise itself as capable
of receiving.  This value is used for BFD sessions that
do not have a corresponding entry in the BFD Session Table.

Context

MIB
DC-BFD-STUB-MIB
OID
.1.3.6.1.4.1.629.10.11.1.1.1.7
Type
column
Access
readwrite
Status
current
Units
microseconds
Parent
bfdEntityEntry
Table
bfdEntityTable
Siblings
7

Syntax

microseconds BfdInterval
Source
BfdInterval
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 1..4294967295

Related Objects

Sibling Objects