dpStatusVoltageSensorsReadingStatus
DATAPOWER-STATUS-MIB ·
.1.3.6.1.4.1.14685.3.1.140.1.5
Object
column
Enumeration
An indicator of whether the current voltage is OK or the voltage exceeds the upper or lower critical threshold. If the status is not OK, check whether the temperature is too high or the fan does not work. If the temperature is normal and the fan works, the appliance must have failed. Replace the appliance.
Context
- MIB
- DATAPOWER-STATUS-MIB
- OID
.1.3.6.1.4.1.14685.3.1.140.1.5- Type
- column
- Access
- readonly
- Status
- current
- Parent
- dpStatusVoltageSensorsEntry
- Table
- dpStatusVoltageSensorsTable
- Siblings
- 4
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dpStatusVoltageSensorsName The name of the voltage sensor that is being monitored. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.14685.3.1.140.1.1 |
| dpStatusVoltageSensorsValue The most recent reading of the voltage sensor in millivolts. There are
only three significant digits. | column | mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.14685.3.1.140.1.2 |
| dpStatusVoltageSensorsLowerCriticalThreshold The lowest allowable reading of the voltage sensor in millivolts. | column | mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.14685.3.1.140.1.3 |
| dpStatusVoltageSensorsUpperCriticalThreshold The highest allowable reading of the voltage sensor in millivolts. | column | mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.14685.3.1.140.1.4 |