dpStatusRaidBatteryBackUpStatusDesignVoltage
DATAPOWER-STATUS-MIB ·
.1.3.6.1.4.1.14685.3.1.258.1.10
Object
The designed voltage of the battery in millivolts.
Context
- MIB
- DATAPOWER-STATUS-MIB
- OID
.1.3.6.1.4.1.14685.3.1.258.1.10- Type
- column
- Access
- readonly
- Status
- current
- Units
- mV
- Parent
- dpStatusRaidBatteryBackUpStatusEntry
- Table
- dpStatusRaidBatteryBackUpStatusTable
- Siblings
- 17
Syntax
mV SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dpStatusRaidBatteryBackUpStatusControllerID The reference number of the RAID controller. The value is always 1. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.1 |
| dpStatusRaidBatteryBackUpStatusRemainingCapacity The predicted capacity remaining in the battery in milliampere-hour. | column | mAh SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.11 |
| dpStatusRaidBatteryBackUpStatusFullChargeCapacity The predicted capacity of the battery when fully charged in
milliampere-hour. | column | mAh SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.12 |
| dpStatusRaidBatteryBackUpStatusRunTimeToEmpty The relative gain or loss of the battery in response to a change in the
power policy in minutes. | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.13 |
| dpStatusRaidBatteryBackUpStatusAvgTimeToEmpty The time in minutes to deplete the battery. The time is calculated based
on the 1-minute rolling average of the power that is being charged to the
battery. | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.14 |
| dpStatusRaidBatteryBackUpStatusAvgTimeToFull Time in minutes to fully charge the battery. The time is calculated based
on the 1-minute rolling average of the power that is being charged to the
battery. | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.15 |
| dpStatusRaidBatteryBackUpStatusCycleCount The number of charge cycles that the battery has experienced. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.16 |
| dpStatusRaidBatteryBackUpStatusRemainingCapacityAlarm The threshold of the remaining capacity in milliampere-hour. When the
threshold is reached, the system will throw an alarm. If the 'Battery
Type' is iBBU08, this is deprecated and… | column | mAh SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.17 |
| dpStatusRaidBatteryBackUpStatusRemainingTimeAlarm The threshold of the remaining time in minutes. When the threshold is
reached, the system will throw an alarm. If the 'Battery Type' is iBBU08,
this is deprecated and does not dis… | column | minutes SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.18 |
| dpStatusRaidBatteryBackUpStatusBatteryType The type of the BBU. | column | Enumeration | .1.3.6.1.4.1.14685.3.1.258.1.2 |
| dpStatusRaidBatteryBackUpStatusSerial The serial number of the BBU. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.3 |
| dpStatusRaidBatteryBackUpStatusName The product name of the BBU. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.14685.3.1.258.1.4 |
| dpStatusRaidBatteryBackUpStatusStatus The status of the BBU. | column | Enumeration | .1.3.6.1.4.1.14685.3.1.258.1.5 |
| dpStatusRaidBatteryBackUpStatusVoltage The actual voltage of the battery in millivolts. | column | mV SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.6 |
| dpStatusRaidBatteryBackUpStatusCurrent The current that flows through the battery terminals in milliamperes. | column | mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.14685.3.1.258.1.7 |
| dpStatusRaidBatteryBackUpStatusTemperature The temperature of the battery in degrees Celcius. | column | C SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.8 |
| dpStatusRaidBatteryBackUpStatusDesignCapacity The designed capacity of the battery in milliampere-hour. | column | mAh SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.14685.3.1.258.1.9 |