flowPolicyPollingServerRetryInterval
CTRON-LFAP-MIB ·
.1.3.6.1.4.1.52.4.1.5.11.3.6
Object
scalar
r/w
Integer32
This object specifies the time in seconds to wait before trying to connect to the server(s) in the list after being unable to connect to any of the server(s).
Context
- MIB
- CTRON-LFAP-MIB
- OID
.1.3.6.1.4.1.52.4.1.5.11.3.6- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- flowPolicyPolling
- Siblings
- 7
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-2000
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| flowPolicyPollingTimerInterval This object contains the number of minutes between statistics polling
periods. | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.5.11.3.1 |
| flowPolicyPollingBatchSize This object specifies the number of connections that comprise a batch for
polling purposes. | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.5.11.3.2 |
| flowPolicyPollingBatchInterval This object contains the current number of milliseconds between statistics
polling batches. A polling period is divided into polling batches, the
duration between which is calcul… | scalar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.52.4.1.5.11.3.3 |
| flowPolicyPollingBatchUpdateInterval This object specifies the time in seconds to send flow create and delete
information to the server. | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.5.11.3.4 |
| flowPolicyPollingLostContactInterval This object specifies the time to wait in seconds until the CCE realizes it
has lost contact with a server. | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.5.11.3.5 |
| flowPolicyPollingSendQueueMaxSize This object specifies the maximum number of messages the send queue can hold
before messages are dropped. | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.5.11.3.7 |
| flowPolicyPollingTaskPriority This object specifies the task priority of LFAP. | scalar | Integer32 | .1.3.6.1.4.1.52.4.1.5.11.3.8 |