fom04RemoteEntry
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.251.20.1
Object
row
An entry containing management information applicable to a particular remote FRM220-FOM04 series card.
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.251.20.1- Type
- row
- Status
- current
- Parent
- fom04RemoteTable
- Table
- fom04RemoteTable
- Children
- 103
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fom04ChassisIndexRemote A unique value for each remote card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.251.20.1.1 |
| fom04FxLinkRemote Remote FRM220-FOM04 fiber link status:
0:Down
1:up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.10 |
| fom04Fx2DDRxPWRRemote Remote device card fiber port 2 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.100 |
| fom04Fx2DDTempRemote Remote device card fiber port 2 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.101 |
| fom04Fx2DDPWRMarginRemote Remote device card fiber port 2 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.251.20.1.102 |
| fom04FxFEFRemote Remote device card fiber detected Far End Fault:
0:Undetect
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.103 |
| fom04FxWorkCHRemote Remote FRM220-FOM04 fiber work channel:
0:Optical 1
1:Optical 2 | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.11 |
| fom04Fx1RxLinkRemote Remote FRM220-FOM04 fiber 1 rx loss status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.12 |
| fom04Fx2RxLinkRemote Remote FRM220-FOM04 fiber 1 rx loss status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.13 |
| fom04FxLBSettingRemote Remote FRM220-FOM04 loopback mode:
0:Disable
1:LLB
2:RLB | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.14 |
| fom04Utp1LinkRemote Remote FRM220-FOM04 UTP 1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.15 |
| fom04Utp1NegoSTSRemote Remote FRM220-FOM04 UTP 1 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.16 |
| fom04Utp1SpeedSTSRemote Remote FRM220-FOM04 UTP 1 speed status:
0:10M
1:100M | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.17 |
| fom04Utp1DuplexSTSRemote Remote FRM220-FOM04 UTP 1 duplex status:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.18 |
| fom04Utp1ActiveRemote Remote FRM220-FOM04 UTP 1 port active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.19 |
| fom04SlotIndexRemote A unique value for each remote card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.251.20.1.2 |
| fom04Utp1NegoRemote Remote FRM220-FOM04 UTP 1 negoiation:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.20 |
| fom04Utp1SpeedRemote Remote FRM220-FOM04 UTP 1 speed:
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.21 |
| fom04Utp1DuplexRemote Remote FRM220-FOM04 UTP 1 duplex:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.22 |
| fom04Utp2LinkRemote Remote FRM220-FOM04 UTP 2 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.23 |
| fom04Utp2NegoSTSRemote Remote FRM220-FOM04 UTP 2 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.24 |
| fom04Utp2SpeedSTSRemote Remote FRM220-FOM04 UTP 2 speed status:
0:10M
1:100M | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.25 |
| fom04Utp2DuplexSTSRemote Remote FRM220-FOM04 UTP 2 duplex status:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.26 |
| fom04Utp2ActiveRemote Remote FRM220-FOM04 UTP 2 port active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.27 |
| fom04Utp2NegoRemote Remote FRM220-FOM04 UTP 2 negoiation:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.28 |
| fom04Utp2SpeedRemote Remote FRM220-FOM04 UTP 2 speed:
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.29 |
| fom04CardHWVerRemote Remote FRM220-FOM04 Series card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.3 |
| fom04Utp2DuplexRemote Remote FRM220-FOM04 UTP 2 duplex:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.30 |
| fom04Utp3LinkRemote Remote FRM220-FOM04 UTP 3 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.31 |
| fom04Utp3NegoSTSRemote Remote FRM220-FOM04 UTP 3 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.32 |
| fom04Utp3SpeedSTSRemote Remote FRM220-FOM04 UTP 3 speed status:
0:10M
1:100M | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.33 |
| fom04Utp3DuplexSTSRemote Remote FRM220-FOM04 UTP 3 duplex status:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.34 |
| fom04Utp3ActiveRemote Remote FRM220-FOM04 UTP 3 port active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.35 |
| fom04Utp3NegoRemote Remote FRM220-FOM04 UTP 3 negoiation:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.36 |
| fom04Utp3SpeedRemote Remote FRM220-FOM04 UTP 3 speed:
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.37 |
| fom04Utp3DuplexRemote Remote FRM220-FOM04 UTP 3 duplex:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.38 |
| fom04RS232ActiveRemote Remote FRM220-FOM04 RS232 port active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.39 |
| fom04CardFWVerRemote Remote FRM220-FOM04 Series card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.4 |
| fom04RS232DataActiveRemote Remote FRM220-FOM04 RS232 Rx active status:
0:OFF
1:ON | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.40 |
| fom04RS232LBSettingRemote Remote FRM220-FOM04 RS232 loopback :
0:Disable
1:LLB
2:RLB | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.41 |
| fom04E1T1TermRemote Remote FRM220-FOM04 E1T1 termination type:
0:E1/75/BNC
1:E1/120/RJ45
2:T1/100/RJ45 | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.42 |
| fom04E1T1CH1ActiveRemote Remote FRM220-FOM04 E1T1 channel 1 port active :
0:Disable
1:Enalbe | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.43 |
| fom04E1T1CH1LinkRemote Remote FRM220-FOM04 E1T1 channel 1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.44 |
| fom04E1T1CH1BVPErrorRemote Remote FRM220-FOM04 E1T1 channel 1 BVP error status :
0:Normal
1:Error | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.45 |
| fom04E1T1CH1LineCodeRemote Remote FRM220-FOM04 E1T1 channel 1 line code:
0:HDB3/B8ZS
1:AMI | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.46 |
| fom04E1T1CH1ELBRemote Remote FRM220-FOM04 E1T1 channel 1 E1 loopback:
0:Disable
1:LLB
2:RLB | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.47 |
| fom04E1T1CH1RcvAISRemote Remote FRM220-FOM04 E1T1 channel 1 Rev AIS:
0:OFF
1:ON | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.48 |
| fom04E1T1CH2ActiveRemote Remote FRM220-FOM04 E1T1 channel 2 port active :
0:Disable
1:Enalbe | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.49 |
| fom04CardCPLDVerRemote Remote FRM220-FOM04 Series card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.5 |
| fom04E1T1CH2LinkRemote Remote FRM220-FOM04 E1T1 channel 2 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.50 |
| fom04E1T1CH2BVPErrorRemote Remote FRM220-FOM04 E1T1 channel 2 BVP error status :
0:Normal
1:Error | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.51 |
| fom04E1T1CH2LineCodeRemote Remote FRM220-FOM04 E1T1 channel 2 line code:
0:HDB3/B8ZS
1:AMI | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.52 |
| fom04E1T1CH2ELBRemote Remote FRM220-FOM04 E1T1 channel 2 E1 loopback:
0:Disable
1:LLB
2:RLB | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.53 |
| fom04E1T1CH2RcvAISRemote Remote FRM220-FOM04 E1T1 channel 2 Rev AIS:
0:OFF
1:ON | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.54 |
| fom04E1T1CH3ActiveRemote Remote FRM220-FOM04 E1T1 channel 3 port active :
0:Disable
1:Enalbe | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.55 |
| fom04E1T1CH3LinkRemote Remote FRM220-FOM04 E1T1 channel 3 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.56 |
| fom04E1T1CH3BVPErrorRemote Remote FRM220-FOM04 E1T1 channel 3 BVP error status :
0:Normal
1:Error | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.57 |
| fom04E1T1CH3LineCodeRemote Remote FRM220-FOM04 E1T1 channel 3 line code:
0:HDB3/B8ZS
1:AMI | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.58 |
| fom04E1T1CH3ELBRemote Remote FRM220-FOM04 E1T1 channel 3 E1 loopback:
0:Disable
1:LLB
2:RLB | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.59 |
| fom04CardFPGAVerRemote Remote FRM220-FOM04 Series card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.6 |
| fom04E1T1CH3RcvAISRemote Remote FRM220-FOM04 E1T1 channel 3 Rev AIS:
0:OFF
1:ON | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.60 |
| fom04E1T1CH4ActiveRemote Remote FRM220-FOM04 E1T1 channel 4 port active :
0:Disable
1:Enalbe | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.61 |
| fom04E1T1CH4LinkRemote Remote FRM220-FOM04 E1T1 channel 4 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.62 |
| fom04E1T1CH4BVPErrorRemote Remote FRM220-FOM04 E1T1 channel 4 BVP error status :
0:Normal
1:Error | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.63 |
| fom04E1T1CH4LineCodeRemote Remote FRM220-FOM04 E1T1 channel 4 line code:
0:HDB3/B8ZS
1:AMI | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.64 |
| fom04E1T1CH4ELBRemote Remote FRM220-FOM04 E1T1 channel 4 E1 loopback:
0:Disable
1:LLB
2:RLB | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.65 |
| fom04E1T1CH4RcvAISRemote Remote FRM220-FOM04 E1T1 channel 4 Rev AIS:
0:OFF
1:ON | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.66 |
| fom04PhoneActiveRemote Remote FRM220-FOM04 phone port active :
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.67 |
| fom04CallOutRemote Remote FRM220-FOM04 call out :
0:OFF
1:ON | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.68 |
| fom04RemotePWRRemote Remote FRM220-FOM04 Remote power fail:
0:Ok
1:Abnormal | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.69 |
| fom04PortActiveRemote Remote FRM220-FOM04 Series card active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.7 |
| fom04LfpModeRemote Remote FRM220-FOM04 LFP mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.70 |
| fom04AlsModeRemote Remote FRM220-FOM04 ALS mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.71 |
| fom04SnmpPortRemote Remote FRM220-FOM04 SNMP VLAN :
0:No VLAN
1:Port 1 VLAN | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.72 |
| fom04PWR1Remote Remote FRM220-FOM04 PWR 1 (AC):
0:Fail
1:Ok
2:None | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.73 |
| fom04PWR2Remote Remote FRM220-FOM04 PWR 2 (DC):
0:Fail
1:Ok
2:None | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.74 |
| fom04Fx1DDRemote Remote device card fiber port 1 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.75 |
| fom04Fx1DDVendorRemote Remote device card fiber port 1 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.76 |
| fom04Fx1DDPartNoRemote Remote device card fiber port 1 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.77 |
| fom04Fx1DDFiberTypeRemote Remote device card fiber port 1 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.78 |
| fom04Fx1DDWaveLenRemote Remote device card fiber port 1 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.79 |
| fom04SettoDefaultRemote Remote FRM220-FOM04 Series card set to default:
0:OFF
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.8 |
| fom04Fx1DDWaveLen2Remote Remote device card fiber port 1 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.80 |
| fom04Fx1DDLinkLenRemote Remote device card fiber port 1 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.81 |
| fom04Fx1DDLenUnitRemote Remote device card fiber port 1 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.82 |
| fom04Fx1DDStatusRemote Remote device card fiber port 1 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.83 |
| fom04Fx1DDRxSensRemote Remote device card fiber port 1 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.84 |
| fom04Fx1DDTxPWRRemote Remote device card fiber port 1 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.85 |
| fom04Fx1DDRxPWRRemote Remote device card fiber port 1 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.86 |
| fom04Fx1DDTempRemote Remote device card fiber port 1 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.87 |
| fom04Fx1DDPWRMarginRemote Remote device card fiber port 1 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.251.20.1.88 |
| fom04Fx2DDRemote Remote device card fiber port 2 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.89 |
| fom04PortResetRemote Remote FRM220-FOM04 Series card portreset:
0:OFF
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.9 |
| fom04Fx2DDVendorRemote Remote device card fiber port 2 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.90 |
| fom04Fx2DDPartNoRemote Remote device card fiber port 2 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.91 |
| fom04Fx2DDFiberTypeRemote Remote device card fiber port 2 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.92 |
| fom04Fx2DDWaveLenRemote Remote device card fiber port 2 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.93 |
| fom04Fx2DDWaveLen2Remote Remote device card fiber port 2 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.94 |
| fom04Fx2DDLinkLenRemote Remote device card fiber port 2 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.95 |
| fom04Fx2DDLenUnitRemote Remote device card fiber port 2 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.96 |
| fom04Fx2DDStatusRemote Remote device card fiber port 2 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.251.20.1.97 |
| fom04Fx2DDRxSensRemote Remote device card fiber port 2 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.98 |
| fom04Fx2DDTxPWRRemote Remote device card fiber port 2 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.251.20.1.99 |