fDATASetDefaultLocal
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.90.20.1.12
Object
column
r/w
Enumeration
Force local FRM220-DATA card to default status: 0:Off 1:Action
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.90.20.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- fDATALocalEntry
- Table
- fDATALocalTable
- Siblings
- 52
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fDATAChassisIndexLocal A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.90.20.1.1 |
| fDATAFxFEFLocal Local FRM220-DATA card fiber detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.10 |
| fDATAPortResetLocal Force local FRM220-DATA card to reset mode:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.11 |
| fDATARdStateLocal Local FRM220-DATA card RD State:
0:on
1:off
2:flash | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.13 |
| fDATATdStateLocal Local FRM220-DATA card TD State:
0:on
1:off
2:flash | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.14 |
| fDATARtsStateLocal Local FRM220-DATA card RTS State:
0:on
1:off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.15 |
| fDATACtsStateLocal Local FRM220-DATA card CTS State:
0:on
1:off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.16 |
| fDATADcdStateLocal Local FRM220-DATA card DCD State:
0:on
1:off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.17 |
| fDATAReDataRateGpLocal Local FRM220-DATA card Receive Data Rate Group
Index Receive Data Rate Group Select
0 Group 1, N*64, N from 1 to 32, 64K~2048K
1 Group 2, N*64K, N from 33 t… | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.18 |
| fDATAReDataRateLocal Local FRM220-DATA card Receive Data Rate
Index Receive Data Rate Select
Group1 Group2 Group3 Group4 Group5 Group6 Group7
0 64K 2112K 4160K 6208K 8256K … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.90.20.1.19 |
| fDATASlotIndexLocal A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.90.20.1.2 |
| fDATAReTimeSourceLocal Local FRM220-DATA card Receive Timing Source State
0:recovery from remote transmit side
1:internal
2:etc/rc input
3:recovery from remote receive side | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.20 |
| fDATATrDataRateGpLocal Local FRM220-DATA card Transmit Data Rate Group
Index Transmit Data Rate Group Select
0 Group 1, N*64, N from 1 to 32, 64K~2048K
1 Group 2, N*64K, N from 33… | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.21 |
| fDATATrDataRateLocal Local FRM220-DATA card Transmit Data Rate
Index Transmit Data Rate Select
Group1 Group2 Group3 Group4 Group5 Group6 Group7
0 64K 2112K 4160K 6208K 8256K… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.90.20.1.22 |
| fDATATrTimeSourceLocal Local FRM220-DATA card Transmit Timing Source State
0:Same as Reveive Timing Source
1:internal
2:etc/rc input
3:recovery from remote receive side | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.23 |
| fDATADsrdtrLocal Local FRM220-DATA card DSR/DTR output setting
0:constantly on
1:follow local dtr/dsr input
2:follow remote dtr/dsr input | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.24 |
| fDATACtsrtsLocal Local FRM220-DATA card CTS/RTS output setting
0:constantly on
1:follow local cts/rts input
2:follow remote cts/rts input | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.25 |
| fDATAEtcLocal Local FRM220-DATA card ETC polarity setting
0:normal
1:invert | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.26 |
| fDATATcLocal Local FRM220-DATA card TC polarity setting
0:normal
1:invert | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.27 |
| fDATARcLocal Local FRM220-DATA card RC polarity setting
0:normal
1:invert | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.28 |
| fDATAAlsModeLocal Local FRM220-DATA card Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.29 |
| fDATACardHWVerLocal Local FRM220-DATA card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.3 |
| fDATADataPortModeLocal Local FRM220-DATA card Data Port Mode setting
0:DCE Mode
1:DTE Mode | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.30 |
| fDATADataPotrinterfaceLocal Local FRM220-DATA card Data Port Interface setting
0:rs530-rs-449-x21
1:v35
2:rs-232 | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.31 |
| fDATALbsettingLocal Local FRM220-DATA card Loop Back Function & Select setting
0:off
1:fiber side llb
2:fiber side rlb
3:fiber side rrlb
5:data port side llb
6:data port side rlb
7:data port side rrlb | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.32 |
| fDATADcdoutsetLocal Local FRM220-DATA card DCD output setting
0:constantly on
1:follow remote dcd input | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.33 |
| fDATADsrStateLocal Local FRM220-DATA card DSR State
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.34 |
| fDATADtrStateLocal Local FRM220-DATA card DTR State
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.35 |
| fDATARlbStateLocal Local FRM220-DATA card RLB State
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.36 |
| fDATALlbStateLocal Local FRM220-DATA card LLB State
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.37 |
| fDATATmStateLocal Local FRM220-DATA card TM State
0:On
1:Off | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.38 |
| fDATAFxDDLocal Local FRM220-DATA card fiber Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.39 |
| fDATACardFWVerLocal Local FRM220-DATA card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.4 |
| fDATADDVendorLocal Local FRM220-DATA card fiber D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.40 |
| fDATADDPartNoLocal Local FRM220-DATA card fiber D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.41 |
| fDATADDFiberTypeLocal Local FRM220-DATA card fiber D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.42 |
| fDATADDWaveLenLocal Local FRM220-DATA card fiber D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.43 |
| fDATADDWaveLen2Local Local FRM220-DATA card fiber D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.44 |
| fDATADDLinkLenLocal Local FRM220-DATA card fiber D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.45 |
| fDATADDLenUnitLocal Local FRM220-DATA card fiber D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.46 |
| fDATADDStatusLocal Local FRM220-DATA card fiber D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.47 |
| fDATADDRxSensLocal Local FRM220-DATA card fiber D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.48 |
| fDATADDTxPwrLocal Local FRM220-DATA card fiber D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.49 |
| fDATACardCPLDVerLocal Local FRM220-DATA card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.5 |
| fDATADDRxPwrLocal Local FRM220-DATA card fiber D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.50 |
| fDATADDTempLocal Local FRM220-DATA card fiber D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.51 |
| fDATADDPwrMarginLocal Local FRM220-DATA card fiber D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.90.20.1.52 |
| fDATADDPwrLossLocal Local FRM220-DATA card fiber D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.90.20.1.53 |
| fDATACardFPGAVerLocal Local FRM220-DATA card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.90.20.1.6 |
| fDATAPortActiveLocal Local FRM220-DATA card active:
0:Inactive
1:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.7 |
| fDATAFxLinkLocal Local FRM220-DATA fiber Link detected:
0:Link Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.8 |
| fDATAFxSignalLocal Local FRM220-DATA fiber signal detected:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.90.20.1.9 |