f100ISUtpSpeedRemoteB
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.182.20.1.12
Object
column
r/w
Enumeration
RemoteB FRM220-10/100IS-2 card UTP3 speed : 0:10MHz 1:100MHz
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.182.20.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- f100ISRemoteBEntry
- Table
- f100ISRemoteBTable
- Siblings
- 54
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| f100ISChassisIndexRemoteB A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.182.20.1.1 |
| f100ISUtpRxActRemoteB RemoteB FRM220-10/100IS-2 card UTP3 receive active status:
0:Off
1:On | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.10 |
| f100ISUtpNegoRemoteB RemoteB FRM220-10/100IS-2 card UTP3 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.11 |
| f100ISUtpDuplexRemoteB RemoteB FRM220-10/100IS-2 card UTP3 duplex Setting:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.13 |
| f100ISUtpSpeedStatusRemoteB RemoteB FRM220-10/100IS-2 card UTP3 speed Status:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.14 |
| f100ISUtpDuplexStatusRemoteB RemoteB FRM220-10/100IS-2 card UTP3 duplex Status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.15 |
| f100ISUtpRxByteRemoteB RemoteB FRM220-10/100IS-2 card UTP3-in octet Setting | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.16 |
| f100ISUtpTxByteRemoteB RemoteB FRM220-10/100IS-2 card UTP3-out octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.17 |
| f100ISUtpFnlRxByteRemoteB RemoteB FRM220-10/100IS-2 card UTP3-in final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.18 |
| f100ISUtpFnlTxByteRemoteB RemoteB FRM220-10/100IS-2 card UTP3-out final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.19 |
| f100ISSlotIndexRemoteB A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.182.20.1.2 |
| f100ISFxLinkRemoteB RemoteB FRM220-10/100IS-2 card fiber1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.20 |
| f100ISFxRxActRemoteB RemoteB FRM220-10/100IS-2 card fiber1 receiver active status:
0:Off
1:On | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.21 |
| f100ISFxFEFRemoteB RemoteB FRM220-10/100IS-2 card fiber1 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.22 |
| f100ISFxLBTestRemoteB Force remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.23 |
| f100ISFxLBStatusRemoteB RemoteB FRM220-10/100IS-2 card fiber1 LoopBack testing status:
0:Off
1:Ok
2:Fail | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.24 |
| f100ISRemoPWRAbRemoteB RemoteB FRM220-10/100IS-2 card fiber1 RemoteB Power status:
0:Abnormal
1:OK | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.25 |
| f100ISIrlModeRemoteB RemoteB FRM220-10/100IS-2 card Ingress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.26 |
| f100ISIrlMultRemoteB RemoteB FRM220-10/100IS-2 card Ingress Rate Limit multiple:
When the irlMode-L is n x 32K mode, the irlMult-L
should be the value between 0 to 255;
When the irlMode-L is n x 512… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.182.20.1.27 |
| f100ISErlModeRemoteB RemoteB FRM220-10/100IS-2 card Egress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.28 |
| f100ISErlMultRemoteB RemoteB FRM220-10/100IS-2 card Egress Rate Limit multiple:
When the erlMode-L is n x 32K mode, the erlMult-L
should be the value between 0 to 255;
When the erlMode-L is n x 512K… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.182.20.1.29 |
| f100ISCardHWVerRemoteB RemoteB FRM220-10/100I card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.3 |
| f100ISRxByteRemoteB RemoteB FRM220-10/100IS-2 card FX1-in octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.30 |
| f100ISTxByteRemoteB RemoteB FRM220-10/100IS-2 card FX1-out octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.31 |
| f100ISFnlRxByteRemoteB RemoteB FRM220-10/100IS-2 card FX1-in final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.32 |
| f100ISFnlTxByteRemoteB RemoteB FRM220-10/100IS-2 card FX1-out final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.33 |
| f100ISPortResetRemoteB Force local FRM220-10/100IS-2 card to reset mode:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.34 |
| f100ISOpModeRemoteB RemoteB FRM220-10/100IS-2 card operation mode:
0:Switch mode
1:Converter mode | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.35 |
| f100ISLfpModeRemoteB RemoteB FRM220-10/100IS-2 card Link Fault Pass-through mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.36 |
| f100ISAlsModeRemoteB RemoteB FRM220-10/100IS-2 card Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.37 |
| f100ISFhrModeRemoteB RemoteB FRM220-10/100IS-2 card accept Fiber Hardware Reset mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.38 |
| f100ISDDRemoteB RemoteB FRM220-10/100IS-2 card fiber1 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.39 |
| f100ISCardFWVerRemoteB RemoteB FRM220-10/100I card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.4 |
| f100ISDDVendorRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.40 |
| f100ISDDPartNoRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.41 |
| f100ISDDFiberTypeRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.42 |
| f100ISDDWaveLenRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.43 |
| f100ISDDWaveLen2RemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.44 |
| f100ISDDLinkLenRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.45 |
| f100ISDDLenUnitRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.46 |
| f100ISDDStatusRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.47 |
| f100ISDDRxSensRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.48 |
| f100ISDDTxPWRRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.49 |
| f100ISCardCPLDVerRemoteB RemoteB FRM220-10/100I card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.5 |
| f100ISDDRxPWRRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.50 |
| f100ISDDTempRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.51 |
| f100ISDDPWRMarginRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.182.20.1.52 |
| f100ISDDPWRLossRemoteB RemoteB FRM220-10/100IS-2 card fiber1 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.182.20.1.53 |
| f100ISInfoR1SN1RemoteB RemoteB FRM220-10/100IS-2 card INFORemoteBOM S/N 1 information | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.54 |
| f100ISInfoR1SN2RemoteB RemoteB FRM220-10/100IS-2 card INFORemoteBOM S/N 2 information | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.55 |
| f100ISCardFPGAVerRemoteB RemoteB FRM220-10/100I card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.182.20.1.6 |
| f100ISPortActiveRemoteB RemoteB FRM220-10/100IS-2 card FX1 active:
0:Inactive
1:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.7 |
| f100ISInBandManagRemoteB RemoteB FRM220-10/100IS-2 card manages remote:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.8 |
| f100ISUtpLinkRemoteB RemoteB FRM220-10/100IS-2 card UTP3 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.182.20.1.9 |