f100ISFx1LBStatusLocal
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.180.20.1.41
Object
column
Enumeration
Local FRM220-10/100IS-2 card fiber1 LoopBack testing status: 0:Off 1:Ok 2:Fail
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.180.20.1.41- Type
- column
- Access
- readonly
- Status
- current
- Parent
- f100ISLocalEntry
- Table
- f100ISLocalTable
- Siblings
- 100
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| f100ISChassisIndexLocal A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.180.20.1.1 |
| f100ISFx2InBandManagLocal Local FRM220-10/100IS-2 card Fx2 manages remote:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.10 |
| f100ISInfoR1SN1Local Local FRM220-10/100IS-2 card INFORemoteOM S/N 1 information | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.100 |
| f100ISInfoR1SN2Local Local FRM220-10/100IS-2 card INFORemoteOM S/N 2 information | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.101 |
| f100ISUtp3LinkLocal Local FRM220-10/100IS-2 card UTP3 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.11 |
| f100ISUtp4LinkLocal Local FRM220-10/100IS-2 card UTP4 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.12 |
| f100ISUtp3RxActLocal Local FRM220-10/100IS-2 card UTP3 receive active status:
0:Off
1:On | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.13 |
| f100ISUtp4RxActLocal Local FRM220-10/100IS-2 card UTP4 receive active status:
0:Off
1:On | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.14 |
| f100ISUtp3NegoLocal Local FRM220-10/100IS-2 card UTP3 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.15 |
| f100ISUtp4NegoLocal Local FRM220-10/100IS-2 card UTP4 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.16 |
| f100ISUtp3SpeedLocal Local FRM220-10/100IS-2 card UTP3 speed:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.17 |
| f100ISUtp4SpeedLocal Local FRM220-10/100IS-2 card UTP4 speed:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.18 |
| f100ISUtp3DuplexLocal Local FRM220-10/100IS-2 card UTP3 duplex:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.19 |
| f100ISSlotIndexLocal A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.180.20.1.2 |
| f100ISUtp4DuplexLocal Local FRM220-10/100IS-2 card UTP4 duplex:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.20 |
| f100ISUtp3RxByteLocal Local FRM220-10/100IS-2 card UTP3-in octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.21 |
| f100ISUtp4RxByteLocal Local FRM220-10/100IS-2 card UTP4-in octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.22 |
| f100ISUtp3TxByteLocal Local FRM220-10/100IS-2 card UTP3-out octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.23 |
| f100ISUtp4TxByteLocal Local FRM220-10/100IS-2 card UTP4-out octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.24 |
| f100ISUtp3FnlRxByteLocal Local FRM220-10/100IS-2 card UTP3-in final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.25 |
| f100ISUtp4FnlRxByteLocal Local FRM220-10/100IS-2 card UTP4-in final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.26 |
| f100ISUtp3FnlTxByteLocal Local FRM220-10/100IS-2 card UTP3-out final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.27 |
| f100ISUtp4FnlTxByteLocal Local FRM220-10/100IS-2 card UTP4-out final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.28 |
| f100ISUtp3SpeedStatusLocal Local FRM220-10/100IS-2 Utp3 Speed Status:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.29 |
| f100ISCardHWVerLocal Local FRM220-10/100I card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.3 |
| f100ISUtp4SpeedStatusLocal Local FRM220-10/100IS-2 Utp4 Speed Status:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.30 |
| f100ISUtp3DuplexStatusLocal Local FRM220-10/100IS-2 Utp3 Duplex Status:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.31 |
| f100ISUtp4DuplexStatusLocal Local FRM220-10/100IS-2 Utp4 Duplex Status:
0:Half
1:Full | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.32 |
| f100ISFx1LinkLocal Local FRM220-10/100IS-2 card fiber1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.33 |
| f100ISFx2LinkLocal Local FRM220-10/100IS-2 card fiber2 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.34 |
| f100ISFx1RxActLocal Local FRM220-10/100IS-2 card fiber1 receiver active status:
0:Off
1:On | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.35 |
| f100ISFx2RxActLocal Local FRM220-10/100IS-2 card fiber2 receiver active status:
0:Off
1:On | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.36 |
| f100ISFx1FEFLocal Local FRM220-10/100IS-2 card fiber1 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.37 |
| f100ISFx2FEFLocal Local FRM220-10/100IS-2 card fiber2 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.38 |
| f100ISFx1LBTestLocal Force remote FRM220-10/100IS-2 card to do fiber1 LoopBack testing:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.39 |
| f100ISCardFWVerLocal Local FRM220-10/100I card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.4 |
| f100ISFx2LBTestLocal Force remote FRM220-10/100IS-2 card to do fiber2 LoopBack testing:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.40 |
| f100ISFx2LBStatusLocal Local FRM220-10/100IS-2 card fiber2 LoopBack testing status:
0:Off
1:Ok
2:Fail | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.42 |
| f100ISFx1RemoPWRAbLocal Local FRM220-10/100IS-2 card fiber1 Remote Power status:
0:Abnormal
1:OK | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.43 |
| f100ISFx2RemoPWRAbLocal Local FRM220-10/100IS-2 card fiber2 Remote Power status:
0:Abnormal
1:OK | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.44 |
| f100ISFx1IrlModeLocal Local FRM220-10/100IS-2 card Fx1 Ingress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.45 |
| f100ISFx2IrlModeLocal Local FRM220-10/100IS-2 card Fx2 Ingress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.46 |
| f100ISFx1IrlMultLocal Local FRM220-10/100IS-2 card Fx1 Ingress Rate Limit multiple:
When the irlMode-L is n x 32K mode, the Fx1 irlMult-L
should be the value between 0 to 255;
When the irlMode-L is n x… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.47 |
| f100ISFx2IrlMultLocal Local FRM220-10/100IS-2 card Fx2 Ingress Rate Limit multiple:
When the irlMode-L is n x 32K mode, the Fx2 irlMult-L
should be the value between 0 to 255;
When the irlMode-L is n x… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.48 |
| f100ISFx1ErlModeLocal Local FRM220-10/100IS-2 card Fx1 Egress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.49 |
| f100ISCardCPLDVerLocal Local FRM220-10/100I card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.5 |
| f100ISFx2ErlModeLocal Local FRM220-10/100IS-2 card Fx2 Egress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.50 |
| f100ISFx1ErlMultLocal Local FRM220-10/100IS-2 card Fx1 Egress Rate Limit multiple:
When the erlMode-L is n x 32K mode, the Fx1 erlMult-L
should be the value between 0 to 255;
When the erlMode-L is n x … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.51 |
| f100ISFx2ErlMultLocal Local FRM220-10/100IS-2 card Fx2 Egress Rate Limit multiple:
When the erlMode-L is n x 32K mode, the Fx2 erlMult-L
should be the value between 0 to 255;
When the erlMode-L is n x … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.52 |
| f100ISFx1RxByteLocal Local FRM220-10/100IS-2 card FX1-in octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.53 |
| f100ISFx2RxByteLocal Local FRM220-10/100IS-2 card FX2-in octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.54 |
| f100ISFx1TxByteLocal Local FRM220-10/100IS-2 card FX1-out octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.55 |
| f100ISFx2TxByteLocal Local FRM220-10/100IS-2 card FX2-out octet counter | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.56 |
| f100ISFx1FnlRxByteLocal Local FRM220-10/100IS-2 card FX1-in final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.57 |
| f100ISFx2FnlRxByteLocal Local FRM220-10/100IS-2 card FX2-in final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.58 |
| f100ISFx1FnlTxByteLocal Local FRM220-10/100IS-2 card FX1-out final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.59 |
| f100ISCardFPGAVerLocal Local FRM220-10/100I card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.6 |
| f100ISFx2FnlTxByteLocal Local FRM220-10/100IS-2 card FX2-out final octets | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.60 |
| f100ISPortResetLocal Force local FRM220-10/100IS-2 card to Fx1 reset mode:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.61 |
| f100ISFx1OpModeLocal Local FRM220-10/100IS-2 card Fx1 operation mode:
0:Switch mode
1:Converter mode | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.62 |
| f100ISFx2OpModeLocal Local FRM220-10/100IS-2 card Fx2 operation mode:
0:Switch mode
1:Converter mode | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.63 |
| f100ISFx1LfpModeLocal Local FRM220-10/100IS-2 card Fx1 Link Fault Pass-through mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.64 |
| f100ISFx2LfpModeLocal Local FRM220-10/100IS-2 card Fx2 Link Fault Pass-through mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.65 |
| f100ISFx1AlsModeLocal Local FRM220-10/100IS-2 card Fx1 Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.66 |
| f100ISFx2AlsModeLocal Local FRM220-10/100IS-2 card Fx2 Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.67 |
| f100ISFx1SendFHRLocal Local FRM220-10/100IS-2 card Fx1 send Fiber Hardware Reset
to remote:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.68 |
| f100ISFx2SendFHRLocal Local FRM220-10/100IS-2 card Fx2 send Fiber Hardware Reset
to remote:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.69 |
| f100ISFx1PortActiveLocal Local FRM220-10/100IS-2 card FX1 active:
0:Inactive
1:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.7 |
| f100ISFx1DDLocal Local FRM220-10/100IS-2 card fiber1 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.70 |
| f100ISFx2DDLocal Local FRM220-10/100IS-2 card fiber2 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.71 |
| f100ISFx1DDVendorLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.72 |
| f100ISFx2DDVendorLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.73 |
| f100ISFx1DDPartNoLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.74 |
| f100ISFx2DDPartNoLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.75 |
| f100ISFx1DDFiberTypeLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.76 |
| f100ISFx2DDFiberTypeLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.77 |
| f100ISFx1DDWaveLenLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.78 |
| f100ISFx2DDWaveLenLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.79 |
| f100ISFx2PortActiveLocal Local FRM220-10/100IS-2 card FX2 active:
0:Inactive
1:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.8 |
| f100ISFx1DDWaveLen2Local Local FRM220-10/100IS-2 card fiber1 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.80 |
| f100ISFx2DDWaveLen2Local Local FRM220-10/100IS-2 card fiber2 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.81 |
| f100ISFx1DDLinkLenLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.82 |
| f100ISFx2DDLinkLenLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.83 |
| f100ISFx1DDLenUnitLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.84 |
| f100ISFx2DDLenUnitLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.85 |
| f100ISFx1DDStatusLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.86 |
| f100ISFx2DDStatusLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.87 |
| f100ISFx1DDRxSensLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.88 |
| f100ISFx2DDRxSensLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.89 |
| f100ISFx1InBandManagLocal Local FRM220-10/100IS-2 card Fx1 manages remote:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.180.20.1.9 |
| f100ISFx1DDTxPWRLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.90 |
| f100ISFx2DDTxPWRLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.91 |
| f100ISFx1DDRxPWRLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.92 |
| f100ISFx2DDRxPWRLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.93 |
| f100ISFx1DDTempLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.94 |
| f100ISFx2DDTempLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.180.20.1.95 |
| f100ISFx1DDPWRMarginLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.96 |
| f100ISFx2DDPWRMarginLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.97 |
| f100ISFx1DDPWRLossLocal Local FRM220-10/100IS-2 card fiber1 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.98 |
| f100ISFx2DDPWRLossLocal Local FRM220-10/100IS-2 card fiber2 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.180.20.1.99 |