f100I2EIrl1ModeLocal
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.280.20.1.28
Object
column
r/w
Enumeration
Local FRM220-10/100I-2E card UTP 1 Ingress Rate Limit mode: 0:No limit 1:n x 32K 2:n x 512K
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.280.20.1.28- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- f100I2ELocalEntry
- Table
- f100I2ELocalTable
- Siblings
- 53
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| f100I2EChassisIndexLocal A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.280.20.1.1 |
| f100I2EFxLinkLocal Local FRM220-10/100I-2E card fiber link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.10 |
| f100I2EFxFEFLocal Local FRM220-10/100I-2E card fiber detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.11 |
| f100I2EFxRemoPWRAbLocal Local FRM220-10/100I-2E card fiber Remote Power status:
0:Abnormal
1:OK | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.12 |
| f100I2EInBandManagLocal Local FRM220-10/100I-2E card manages remote:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.13 |
| f100I2EUtp1LinkLocal Local FRM220-10/100I-2E card UTP 1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.14 |
| f100I2EUtp1NegoLocal Local FRM220-10/100I-2E card UTP 1 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.15 |
| f100I2EUtp1SpeedLocal Local FRM220-10/100I-2E card UTP 1 speed:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.16 |
| f100I2EUtp1DuplexLocal Local FRM220-10/100I-2E card UTP 1 duplex:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.17 |
| f100I2EUtp1SpeedStatusLocal Local FRM220-10/100I-2E card UTP 1 speed status:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.18 |
| f100I2EUtp1DuplexStatusLocal Local FRM220-10/100I-2E card UTP 1 duplex status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.19 |
| f100I2ESlotIndexLocal A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.280.20.1.2 |
| f100I2EUtp1VIDNumberLocal Local FRM220-10/100I-2E card UTP 1 VID number (1~4094) | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.20 |
| f100I2EUtp2LinkLocal Local FRM220-10/100I-2E card UTP 2 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.21 |
| f100I2EUtp2NegoLocal Local FRM220-10/100I-2E card UTP 2 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.22 |
| f100I2EUtp2SpeedLocal Local FRM220-10/100I-2E card UTP 2 speed:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.23 |
| f100I2EUtp2DuplexLocal Local FRM220-10/100I-2E card UTP 2 duplex:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.24 |
| f100I2EUtp2SpeedStatusLocal Local FRM220-10/100I-2E card UTP 2 speed status:
0:10MHz
1:100MHz | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.25 |
| f100I2EUtp2DuplexStatusLocal Local FRM220-10/100I-2E card UTP 2 duplex status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.26 |
| f100I2EUtp2VIDNumberLocal Local FRM220-10/100I-2E card UTP 2 VID number (1~4094) | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.27 |
| f100I2EIrl1MultLocal Local FRM220-10/100I-2E card UTP 1 Ingress Rate Limit multiple:
When the irlMode-L is n x 32K mode, the irlMult-L
should be the value between 0 to 255;
When the irlMode-L is n x 5… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.29 |
| f100I2ECardHWVerLocal Local FRM220-10/100I-2E card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.3 |
| f100I2EErl1ModeLocal Local FRM220-10/100I-2E card UTP 1 Egress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.30 |
| f100I2EErl1MultLocal Local FRM220-10/100I-2E card UTP 1 Egress Rate Limit multiple:
When the erlMode-L is n x 32K mode, the erlMult-L
should be the value between 0 to 255;
When the erlMode-L is n x 51… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.31 |
| f100I2EIrl2ModeLocal Local FRM220-10/100I-2E card UTP 2 Ingress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.32 |
| f100I2EIrl2MultLocal Local FRM220-10/100I-2E card UTP 2 Ingress Rate Limit multiple:
When the irlMode-L is n x 32K mode, the irlMult-L
should be the value between 0 to 255;
When the irlMode-L is n x 5… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.33 |
| f100I2EErl2ModeLocal Local FRM220-10/100I-2E card UTP 2 Egress Rate Limit mode:
0:No limit
1:n x 32K
2:n x 512K | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.34 |
| f100I2EErl2MultLocal Local FRM220-10/100I-2E card UTP 2 Egress Rate Limit multiple:
When the erlMode-L is n x 32K mode, the erlMult-L
should be the value between 0 to 255;
When the erlMode-L is n x 51… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.35 |
| f100I2EOpModeLocal Local FRM220-10/100I-2E card operation mode:
0:Switch mode
1:Tag based VLAN mode | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.36 |
| f100I2ELfpModeLocal Local FRM220-10/100I-2E card Link Fault Pass-through mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.37 |
| f100I2EAlsModeLocal Local FRM220-10/100I-2E card Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.38 |
| f100I2ESendFHRLocal Local FRM220-10/100I-2E card send Fiber Hardware Reset
to remote:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.39 |
| f100I2ECardFWVerLocal Local FRM220-10/100I-2E card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.4 |
| f100I2EFxDDLocal Local FRM220-10/100I-2E card fiber Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.40 |
| f100I2EDDVendorLocal Local FRM220-10/100I-2E card fiber D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.41 |
| f100I2EDDPartNoLocal Local FRM220-10/100I-2E card fiber D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.42 |
| f100I2EDDFiberTypeLocal Local FRM220-10/100I-2E card fiber D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.43 |
| f100I2EDDWaveLenLocal Local FRM220-10/100I-2E card fiber D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.44 |
| f100I2EDDWaveLen2Local Local FRM220-10/100I-2E card fiber D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.45 |
| f100I2EDDLinkLenLocal Local FRM220-10/100I-2E card fiber D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.46 |
| f100I2EDDLenUnitLocal Local FRM220-10/100I-2E card fiber D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.47 |
| f100I2EDDStatusLocal Local FRM220-10/100I-2E card fiber D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.48 |
| f100I2EDDRxSensLocal Local FRM220-10/100I-2E card fiber D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.49 |
| f100I2ECardCPLDVerLocal Local FRM220-10/100I-2E card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.5 |
| f100I2EDDTxPWRLocal Local FRM220-10/100I-2E card fiber D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.50 |
| f100I2EDDRxPWRLocal Local FRM220-10/100I-2E card fiber D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.51 |
| f100I2EDDTempLocal Local FRM220-10/100I-2E card fiber D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.52 |
| f100I2EDDPWRMarginLocal Local FRM220-10/100I-2E card fiber D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.53 |
| f100I2EDDPWRLossLocal Local FRM220-10/100I-2E card fiber D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.280.20.1.54 |
| f100I2ECardFPGAVerLocal Local FRM220-10/100I-2E card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.280.20.1.6 |
| f100I2EPortActiveLocal Local FRM220-10/100I-2E card active:
0:Inactive
1:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.7 |
| f100I2EPortResetLocal Force local FRM220-10/100I-2E card to reset mode:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.8 |
| f100I2ESettoDefaultLocal Local FRM220-10/100I-2E card Set to default:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.280.20.1.9 |