f100GE2QPortReset
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.710.20.1.7
Object
column
r/w
Enumeration
Local FRM220-100GE-2Q Line Card Port Reset feature: 0:Inactive 1:Active
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.710.20.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- f100GE2QEntry
- Table
- f100GE2QTable
- Siblings
- 117
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| f100GE2QChassisIndex A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.710.20.1.1 |
| f100GE2QClientPresent Local FRM220-100GE-2Q Line Card Client Fiber Port Present:
0:NO
1:YES | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.10 |
| f100GE2QClient2TxLaserBias Local FRM220-100GE-2Q Line Card Client2 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.100 |
| f100GE2QClient3TxPower Local FRM220-100GE-2Q Line Card Client3 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.101 |
| f100GE2QClient3RxPower Local FRM220-100GE-2Q Line Card Client3 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.102 |
| f100GE2QClient3TxLaserBias Local FRM220-100GE-2Q Line Card Client3 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.103 |
| f100GE2QClient4TxPower Local FRM220-100GE-2Q Line Card Client4 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.104 |
| f100GE2QClient4RxPower Local FRM220-100GE-2Q Line Card Client4 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.105 |
| f100GE2QClient4TxLaserBias Local FRM220-100GE-2Q Line Card Client4 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.106 |
| f100GE2QClientTxPowerSum Local FRM220-100GE-2Q Line Card Client Tx Power Sum. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.107 |
| f100GE2QClientRxPowerSum Local FRM220-100GE-2Q Line Card Client Rx Power Sum. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.108 |
| f100GE2QLineLinkAlm Local FRM220-100GE-2Q Line Card Line Link Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.109 |
| f100GE2QLineLink Local FRM220-100GE-2Q Line Card Line Fiber Port Link Status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.11 |
| f100GE2QClientLinkAlm Local FRM220-100GE-2Q Line Card Client Link Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.110 |
| f100GE2QLine1LockAlm Local FRM220-100GE-2Q Line Card Line 1 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.111 |
| f100GE2QLine2LockAlm Local FRM220-100GE-2Q Line Card Line 2 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.112 |
| f100GE2QLine3LockAlm Local FRM220-100GE-2Q Line Card Line 3 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.113 |
| f100GE2QLine4LockAlm Local FRM220-100GE-2Q Line Card Line 4 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.114 |
| f100GE2QClient1LockAlm Local FRM220-100GE-2Q Line Card Client 1 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.115 |
| f100GE2QClient2LockAlm Local FRM220-100GE-2Q Line Card Client 2 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.116 |
| f100GE2QClient3LockAlm Local FRM220-100GE-2Q Line Card Client 3 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.117 |
| f100GE2QClient4LockAlm Local FRM220-100GE-2Q Line Card Client 4 Lock Alarm setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.118 |
| f100GE2QClientLink Local FRM220-100GE-2Q Line Card Client Fiber Port Link Status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.12 |
| f100GE2QLine1CDRLock Local FRM220-100GE-2Q Line Card Line1 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.13 |
| f100GE2QLine2CDRLock Local FRM220-100GE-2Q Line Card Line2 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.14 |
| f100GE2QLine3CDRLock Local FRM220-100GE-2Q Line Card Line3 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.15 |
| f100GE2QLine4CDRLock Local FRM220-100GE-2Q Line Card Line4 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.16 |
| f100GE2QClient1CDRLock Local FRM220-100GE-2Q Line Card Client1 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.17 |
| f100GE2QClient2CDRLock Local FRM220-100GE-2Q Line Card Client2 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.18 |
| f100GE2QClient3CDRLock Local FRM220-100GE-2Q Line Card Client3 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.19 |
| f100GE2QSlotIndex A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.710.20.1.2 |
| f100GE2QClient4CDRLock Local FRM220-100GE-2Q Line Card Client4 Fiber Port CDR Lock Status:
0:Not Locked
1:Locked | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.20 |
| f100GE2QLine1TxFault Local FRM220-100GE-2Q Line Card Line1 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.21 |
| f100GE2QLine2TxFault Local FRM220-100GE-2Q Line Card Line2 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.22 |
| f100GE2QLine3TxFault Local FRM220-100GE-2Q Line Card Line3 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.23 |
| f100GE2QLine4TxFault Local FRM220-100GE-2Q Line Card Line4 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.24 |
| f100GE2QClient1TxFault Local FRM220-100GE-2Q Line Card Client1 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.25 |
| f100GE2QClient2TxFault Local FRM220-100GE-2Q Line Card Client2 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.26 |
| f100GE2QClient3TxFault Local FRM220-100GE-2Q Line Card Client3 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.27 |
| f100GE2QClient4TxFault Local FRM220-100GE-2Q Line Card Client4 Fiber Port Transmit Fault Status:
0:Normal
1:Failure | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.28 |
| f100GE2QPortActive Local FRM220-100GE-2Q Line Card Port Active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.29 |
| f100GE2QCardHWVer Local FRM220-100GE-2Q Line Card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.3 |
| f100GE2QLineActive Local FRM220-100GE-2Q Line Card Line Active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.30 |
| f100GE2QClientActive Local FRM220-100GE-2Q Line Card Client Active:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.31 |
| f100GE2QDataRateSts Local FRM220-100GE-2Q Line Card Data Rate Status. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.32 |
| f100GE2QDataRate Local FRM220-100GE-2Q Line Card Data Rate setting:
0:Ethernet 100GBaseR (PCS)
1:Ethernet 40GBaseR (PCS) | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.33 |
| f100GE2QFEC Local FRM220-100GE-2Q Line Card Data Rate setting:
0:Disable
1:Line side
2:Client side
3:Both side | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.34 |
| f100GE2QLineLBT Local FRM220-100GE-2Q Line Card Line LoopBack Test function setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.35 |
| f100GE2QClientLBT Local FRM220-100GE-2Q Line Card Client LoopBack Test function setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.36 |
| f100GE2QLineALS Local FRM220-100GE-2Q Line Card Line Auto Laser Shutdown setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.37 |
| f100GE2QClientALS Local FRM220-100GE-2Q Line Card Client Auto Laser Shutdown setting:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.38 |
| f100GE2QQSFPLFP Local FRM220-100GE-2Q Line Card both of Line and Client Loss Propagation setting:
0:Disable
1:Line
2:Client
3:Both | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.39 |
| f100GE2QCardFWVer Local FRM220-100GE-2Q Line Card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.4 |
| f100GE2QLineTxPacket Local FRM220-100GE-2Q Line Card Line Tx Packet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.40 |
| f100GE2QLineRxPacket Local FRM220-100GE-2Q Line Card Line Rx Packet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.41 |
| f100GE2QLineErrPacket Local FRM220-100GE-2Q Line Card Line Error Packet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.42 |
| f100GE2QClientTxPacket Local FRM220-100GE-2Q Line Card Client Tx Packet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.43 |
| f100GE2QClientRxPacket Local FRM220-100GE-2Q Line Card Client Rx Packet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.44 |
| f100GE2QClientErrPacket Local FRM220-100GE-2Q Line Card Client Error Packet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.45 |
| f100GE2QLineBERT Local FRM220-100GE-2Q Line Card Line BERT setting:
0:All Disable
1:Packet Transmit Enable
2:Packet Receive Enable
3:All Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.46 |
| f100GE2QClientBERT Local FRM220-100GE-2Q Line Card Client BERT setting:
0:All Disable
1:Packet Transmit Enable
2:Packet Receive Enable
3:All Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.47 |
| f100GE2QClrBERTCnt Clear local device card Bert Counters:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.48 |
| f100GE2QLineVendorName Local FRM220-100GE-2Q Line Card Line Vender Name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.49 |
| f100GE2QCardCPLDVer Local FRM220-100GE-2Q Line Card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.5 |
| f100GE2QLinePartNo Local FRM220-100GE-2Q Line Card Line Part Number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.50 |
| f100GE2QLineSerialNumber Local FRM220-100GE-2Q Line Card Line Part Number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.51 |
| f100GE2QLineTransceiver 100G or 40G QSFP Plus Transceiver.
40G-Active-Cable-XLPPI
40GBASE-LR4
40GBASE-SR4
40GBASE-CR4
10GBASE-SR
10GBASE-LR
10GBASE-LRM
Unspecified
100G AOC or 25GAUI C2M… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.52 |
| f100GE2QLineTransceiver2 100G or 40G QSFP Plus Transceiver2.
40G OTN (OTU3B/OTU3C)
OC 48, short reach
OC 48, intermediate reach
OC 48, long reach | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.53 |
| f100GE2QLineTransceiver3 100G or 40G QSFP Plus Transceiver3.
SAS 12.0G
SAS 24.0G
SAS 3.0G
SAS 6.0G | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.54 |
| f100GE2QLineConnectorType 100G LINE Conncetor Type.
Unknown
SC
FC-Style-1-copper-connector
FC-Style-2-copper-connector
BNC/TNC
FC-coax-headers
Fiberjack
LC
MT-RJ
MU
SG
Optical-Pigtail
MPO
HSSDC-II
Copp… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.55 |
| f100GE2QLineWaveLength1 Local FRM220-100GE-2Q Line Card Line Wave Length 1. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.56 |
| f100GE2QLineWaveLength2 Local FRM220-100GE-2Q Line Card Line Wave Length 2. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.57 |
| f100GE2QLineLinkLength Local FRM220-100GE-2Q Line Card Line Link Length. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.58 |
| f100GE2QLineNominalBitRate Local FRM220-100GE-2Q Line Card Line Nominal Bit Rate. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.59 |
| f100GE2QCardFPGAVer Local FRM220-100GE-2Q Line Card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.6 |
| f100GE2QLineTemp Local FRM220-100GE-2Q Line Card Line Temperature. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.60 |
| f100GE2QLineSupplyVol Local FRM220-100GE-2Q Line Card Line Supply Voltage. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.61 |
| f100GE2QLineTxMaxPower Local FRM220-100GE-2Q Line Card Line Tx Max Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.62 |
| f100GE2QLineRxMaxPower Local FRM220-100GE-2Q Line Card Line Rx Max Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.63 |
| f100GE2QLinePowerClass Local FRM220-100GE-2Q Line Card Line Power Class. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.64 |
| f100GE2QLine1TxPower Local FRM220-100GE-2Q Line Card Line1 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.65 |
| f100GE2QLine1RxPower Local FRM220-100GE-2Q Line Card Line1 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.66 |
| f100GE2QLine1TxLaserBias Local FRM220-100GE-2Q Line Card Line1 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.67 |
| f100GE2QLine2TxPower Local FRM220-100GE-2Q Line Card Line2 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.68 |
| f100GE2QLine2RxPower Local FRM220-100GE-2Q Line Card Line2 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.69 |
| f100GE2QLine2TxLaserBias Local FRM220-100GE-2Q Line Card Line2 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.70 |
| f100GE2QLine3TxPower Local FRM220-100GE-2Q Line Card Line3 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.71 |
| f100GE2QLine3RxPower Local FRM220-100GE-2Q Line Card Line3 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.72 |
| f100GE2QLine3TxLaserBias Local FRM220-100GE-2Q Line Card Line3 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.73 |
| f100GE2QLine4TxPower Local FRM220-100GE-2Q Line Card Line4 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.74 |
| f100GE2QLine4RxPower Local FRM220-100GE-2Q Line Card Line4 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.75 |
| f100GE2QLine4TxLaserBias Local FRM220-100GE-2Q Line Card Line4 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.76 |
| f100GE2QLineTxPowerSum Local FRM220-100GE-2Q Line Card Line Tx Power Sum. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.77 |
| f100GE2QLineRxPowerSum Local FRM220-100GE-2Q Line Card Line Rx Power Sum. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.78 |
| f100GE2QClientVendorName Local FRM220-100GE-2Q Line Card Client Vender Name. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.79 |
| f100GE2QSetDefault Local FRM220-100GE-2Q Line Card Set to Default function:
0:Inactive
1:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.8 |
| f100GE2QClientPartNo Local FRM220-100GE-2Q Line Card Client Part Number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.80 |
| f100GE2QClientSerialNumber Local FRM220-100GE-2Q Line Card Client Serial Number. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.81 |
| f100GE2QClientTransceiver 100G or 40G QSFP Plus Transceiver.
40G-Active-Cable-XLPPI
40GBASE-LR4
40GBASE-SR4
40GBASE-CR4
10GBASE-SR
10GBASE-LR
10GBASE-LRM
Unspecified
100G AOC or 25GAUI C2M… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.82 |
| f100GE2QClientTransceiver2 100G or 40G QSFP Plus Transceiver2.
40G OTN (OTU3B/OTU3C)
OC 48, short reach
OC 48, intermediate reach
OC 48, long reach | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.83 |
| f100GE2QClientTransceiver3 100G or 40G QSFP Plus Transceiver3.
SAS 12.0G
SAS 24.0G
SAS 3.0G
SAS 6.0G | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.84 |
| f100GE2QClientConnectorType 100G or 40G Client Conncetor Type.
Unknown
SC
FC-Style-1-copper-connector
FC-Style-2-copper-connector
BNC/TNC
FC-coax-headers
Fiberjack
LC
MT-RJ
MU
SG
Optical-Pigtail
MPO
HSSD… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.85 |
| f100GE2QClientWaveLength1 Local FRM220-100GE-2Q Line Card Client Wave Length 1. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.86 |
| f100GE2QClientWaveLength2 Local FRM220-100GE-2Q Line Card Client Wave Length 2. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.87 |
| f100GE2QClientLinkLength Local FRM220-100GE-2Q Line Card Client Link Length. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.88 |
| f100GE2QClientNominalBitRate Local FRM220-100GE-2Q Line Card Client Nominal Bit Rate. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.89 |
| f100GE2QLinePresent Local FRM220-100GE-2Q Line Card Line Fiber Port Present:
0:NO
1:YES | column | Enumeration | .1.3.6.1.4.1.4756.20.710.20.1.9 |
| f100GE2QClientTemp Local FRM220-100GE-2Q Line Card Client Temperature. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.90 |
| f100GE2QClientSupplyVol Local FRM220-100GE-2Q Line Card Client Supply Voltage. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.91 |
| f100GE2QClientTxMaxPower Local FRM220-100GE-2Q Line Card Client Tx Max Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.92 |
| f100GE2QClientRxMaxPower Local FRM220-100GE-2Q Line Card Client Rx Max Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.93 |
| f100GE2QClientPowerClass Local FRM220-100GE-2Q Line Card Client Power Class. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.94 |
| f100GE2QClient1TxPower Local FRM220-100GE-2Q Line Card Client1 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.95 |
| f100GE2QClient1RxPower Local FRM220-100GE-2Q Line Card Client1 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.96 |
| f100GE2QClient1TxLaserBias Local FRM220-100GE-2Q Line Card Client1 Transmit Laser BIAS. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.97 |
| f100GE2QClient2TxPower Local FRM220-100GE-2Q Line Card Client2 Transmit Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.98 |
| f100GE2QClient2RxPower Local FRM220-100GE-2Q Line Card Client2 Receive Power. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.710.20.1.99 |