f100ASOamUnknowChBRxLocal
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.190.40.1.150
Object
column
SNMPv2-SMIInteger32
Local device OAM Channel B RX Unsupported OAMPDU frame count
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.190.40.1.150- Type
- column
- Access
- readonly
- Status
- current
- Parent
- f100ASLocalEntry
- Table
- f100ASLocalTable
- Siblings
- 161
Syntax
SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| f100ASChassisIndexLocal A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.190.40.1.1 |
| f100ASFx1LBTestLocal Force remote device card to do fiber port 1 LoopBack testing:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.10 |
| f100ASFx2DDLinkLenLocal Local device card fiber port 2 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.100 |
| f100ASFx2DDLenUnitLocal Local device card fiber port 2 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.101 |
| f100ASFx2DDStatusLocal Local device card fiber port 2 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.102 |
| f100ASFx2DDRxSensLocal Local device card fiber port 2 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.103 |
| f100ASFx2DDTxPWRLocal Local device card fiber port 2 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.104 |
| f100ASFx2DDRxPWRLocal Local device card fiber port 2 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.105 |
| f100ASFx2DDTempLocal Local device card fiber port 2 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.106 |
| f100ASFx2DDPWRMarginLocal Local device card fiber port 2 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.107 |
| f100ASFx2DDPWRLossLocal Local device card fiber port 2 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.108 |
| f100ASClrRMONCntsLocal Clear local device card RMON IN/OUT counters:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.109 |
| f100ASFx1OAMRLBStatusLocal Remote device card fiber port 1 LoopBack testing status:
0:Off
1:Ok
2:Fail | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.11 |
| f100ASFx1RMONInLocal Local device card port 1 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.110 |
| f100ASFx1RMONOutLocal Local device card port 1 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.111 |
| f100ASFx2RMONInLocal Local device card port 2 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.112 |
| f100ASFx2RMONOutLocal Local device card port 2 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.113 |
| f100ASUtp1RMONInLocal Local device card port 3 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.114 |
| f100ASUtp1RMONOutLocal Local device card port 3 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.115 |
| f100ASUtp2RMONInLocal Local device card port 4 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.116 |
| f100ASUtp2RMONOutLocal Local device card port 4 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.117 |
| f100ASClrOAMCntsLocal Clear local device card OAM counters:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.118 |
| f100ASOamChATxLocal Local device OAM Channel A TX OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.119 |
| f100ASFx1RemoPwrAbLocal Local device card fiber port 1 Remote Power status:
0:Abnormal
1:OK
2:None | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.12 |
| f100ASOamChARxLocal Local device OAM Channel A RX OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.120 |
| f100ASOamInfoChATxLocal Local device OAM Channel A TX Information OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.121 |
| f100ASOamInfoChARxLocal Local device OAM Channel A RX Information OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.122 |
| f100ASOamEventChATxLocal Local device OAM Channel A TX Event OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.123 |
| f100ASOamUniEvtChARxLocal Local device OAM Channel A RX Unique Event OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.124 |
| f100ASOamDupEvtChARxLocal Local device OAM Channel A RX Duplicate Event OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.125 |
| f100ASOamLbChATxLocal Local device OAM Channel A TX Loopback Control OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.126 |
| f100ASOamLbChARxLocal Local device OAM Channel A RX Loopback Control OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.127 |
| f100ASOamVarReqChATxLocal Local device OAM Channel A TX Variable Request OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.128 |
| f100ASOamVarReqChARxLocal Local device OAM Channel A RX Variable Request OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.129 |
| f100ASFx2LinkLocal Local device card fiber port 2 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.13 |
| f100ASOamVarRspChATxLocal Local device OAM Channel A TX Variable Response OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.130 |
| f100ASOamVarRspChARxLocal Local device OAM Channel A RX Variable Response OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.131 |
| f100ASOamOuiChATxLocal Local device OAM Channel A TX OUI OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.132 |
| f100ASOamOuiChARxLocal Local device OAM Channel A RX OUI OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.133 |
| f100ASOamUnknowChARxLocal Local device OAM Channel A RX Unsupported OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.134 |
| f100ASOamChBTxLocal Local device OAM Channel B TX OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.135 |
| f100ASOamChBRxLocal Local device OAM Channel B RX OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.136 |
| f100ASOamInfoChBTxLocal Local device OAM Channel B TX Information OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.137 |
| f100ASOamInfoChBRxLocal Local device OAM Channel B RX Information OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.138 |
| f100ASOamEventChBTxLocal Local device OAM Channel B TX Event OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.139 |
| f100ASFx2OAMLoopedLocal Local device card fiber port 2 OAM looped:
0:Off
1:on | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.14 |
| f100ASOamUniEvtChBRxLocal Local device OAM Channel B RX Unique Event OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.140 |
| f100ASOamDupEvtChBRxLocal Local device OAM Channel B RX Duplicate Event OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.141 |
| f100ASOamLbChBTxLocal Local device OAM Channel B TX Loopback Control OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.142 |
| f100ASOamLbChBRxLocal Local device OAM Channel B RX Loopback Control OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.143 |
| f100ASOamVarReqChBTxLocal Local device OAM Channel B TX Variable Request OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.144 |
| f100ASOamVarReqChBRxLocal Local device OAM Channel B RX Variable Request OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.145 |
| f100ASOamVarRspChBTxLocal Local device OAM Channel B TX Variable Response OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.146 |
| f100ASOamVarRspChBRxLocal Local device OAM Channel B RX Variable Response OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.147 |
| f100ASOamOuiChBTxLocal Local device OAM Channel B TX OUI OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.148 |
| f100ASOamOuiChBRxLocal Local device OAM Channel B RX OUI OAMPDU frame count | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.149 |
| f100ASFx2LBTestLocal Force remote device card to do fiber port 2 LoopBack testing:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.15 |
| f100ASFx1FEFLocal Local card fiber1 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.151 |
| f100ASFx2FEFLocal Local card fiber2 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.152 |
| f100ASIpModeLocal On Rack Ip Mode:
0:Enable
1:Disable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.153 |
| f100ASFx1QosPriorityRateLocal Local device Fiber 1 Qos Priority Rate Mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.154 |
| f100ASFx2QosPriorityRateLocal Local device Fiber 2 Qos Priority Rate Mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.155 |
| f100ASUtp1QosPriorityRateLocal Local device Utp 3 Qos Priority Rate Mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.156 |
| f100ASUtp2QosPriorityRateLocal Local device Utp 4 Qos Priority Rate Mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.157 |
| f100ASFx1QosPortPriorityLocal Local device Fiber 1 Qos Port Priority :
0:priority 0
1:priority 1
2:priority 2
3:priority 3 | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.158 |
| f100ASFx2QosPortPriorityLocal Local device Fiber 2 Qos Port Priority :
0:priority 0
1:priority 1
2:priority 2
3:priority 3 | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.159 |
| f100ASFx2OAMRLBStatusLocal Remote device card fiber port 1 LoopBack testing status:
0:Off
1:Ok
2:Fail | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.16 |
| f100ASUtp1QosPortPriorityLocal Local device Utp3 Qos Port Priority :
0:priority 0
1:priority 1
2:priority 2
3:priority 3 | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.160 |
| f100ASUtp2QosPortPriorityLocal Local device Utp4 Qos Port Priority :
0:priority 0
1:priority 1
2:priority 2
3:priority 3 | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.161 |
| f100ASSetDefaultLocal Local device Set to default:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.162 |
| f100ASFx2RemoPwrAbLocal Local device card fiber port 2 Remote Power status:
0:Abnormal
1:OK
2:None | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.17 |
| f100ASUtp1LinkLocal Local device card UTP port 3 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.18 |
| f100ASUtp1NegoLocal Local device card UTP port 3 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.19 |
| f100ASSlotIndexLocal A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.190.40.1.2 |
| f100ASUtp1SpeedLocal Local device card UTP port 3 speed setting:
0:10 Base-T
1:100 Base-TX | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.20 |
| f100ASUtp1DuplexLocal Local device card UTP port 3 duplex setting:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.21 |
| f100ASUtp1SpeedStatusLocal Local device card UTP port 3 speed status:
0:10 Base-T
1:100 Base-TX | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.22 |
| f100ASUtp1DuplexStatusLocal Local device card UTP port 3 duplex status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.23 |
| f100ASUtp2LinkLocal Local device card UTP port 4 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.24 |
| f100ASUtp2NegoLocal Local device card UTP port 4 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.25 |
| f100ASUtp2SpeedLocal Local device card UTP port 4 speed setting:
0:10 Base-T
1:100 Base-TX | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.26 |
| f100ASUtp2DuplexLocal Local device card UTP port 4 duplex setting:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.27 |
| f100ASUtp2SpeedStatusLocal Local device card UTP port 4 speed status:
0:10 Base-T
1:100 Base-TX | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.28 |
| f100ASUtp2DuplexStatusLocal Local device card UTP port 4 duplex status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.29 |
| f100ASCardHWVerLocal Local device card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.3 |
| f100ASFx1IrlModeLocal Local device card port 1 Rate Limit mode:
0:unlimited
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.30 |
| f100ASFx1IrlIndexLocal Local device card port 1 Ingress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.31 |
| f100ASFx1ErlIndexLocal Local device card port 1 Egress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.32 |
| f100ASFx2IrlModeLocal Local device card port 2 Rate Limit mode:
0:unlimited
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.33 |
| f100ASFx2IrlIndexLocal Local device card port 2 Ingress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.34 |
| f100ASFx2ErlIndexLocal Local device card port 2 Egress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.35 |
| f100ASUtp1IrlModeLocal Local device card port 3 Rate Limit mode:
0:unlimited
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.36 |
| f100ASUtp1IrlIndexLocal Local device card port 3 Ingress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.37 |
| f100ASUtp1ErlIndexLocal Local device card port 3 Egress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.38 |
| f100ASUtp2IrlModeLocal Local device card port 4 Rate Limit mode:
0:unlimited
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.39 |
| f100ASCardFWVerLocal Local device card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.4 |
| f100ASUtp2IrlIndexLocal Local device card port 4 Ingress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.40 |
| f100ASUtp2ErlIndexLocal Local device card port 4 Egress Rate Limit index:
Index Limit Rate
0 Unlimited
1 128K
2 256K
3 521K
4 1M
5 2M
6 4M
7 8M | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.41 |
| f100ASDeviceActiveLocal Local device card active mode:
(It is read-only in local device.)
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.42 |
| f100ASDeviceResetLocal Force local device card to reset mode:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.43 |
| f100ASFx1ActiveLocal Local device fiber port 1 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.44 |
| f100ASFx2ActiveLocal Local device fiber port 2 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.45 |
| f100ASUtp1ActiveLocal Local device UTP port 3 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.46 |
| f100ASUtp2ActiveLocal Local device UTP port 4 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.47 |
| f100ASOamChAModeLocal Local device OAM Channel A mode:
0:Disable
1:passive
2:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.48 |
| f100ASOamChBModeLocal Local device OAM Channel B mode:
0:Disable
1:passive
2:Active | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.49 |
| f100ASCardCPLDVerLocal Local device card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.5 |
| f100ASOamMaxPDUsLocal Local device OAM max OAMPDU size: 60-1518 Octets | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.50 |
| f100ASFx1AlsLocal Local device card port 1 Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.51 |
| f100ASFx2AlsLocal Local device card port 2 Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.52 |
| f100ASPauseFrameLocal Local device card pause frame mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.53 |
| f100ASSendFHRtoALocal Local device card port 1 send Fiber Hardware Reset
to remote:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.54 |
| f100ASSendFHRtoBLocal Local device card port 2 send Fiber Hardware Reset
to remote:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.55 |
| f100ASFx1LLFDepLogiLocal Local device card port 1 Link Loss Forwarding
depends boolean logic:
0:and
1:or | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.56 |
| f100ASFx1LLFDepPort2Local Local device card port 1 Link Loss Forwarding
depends on port 2 Fiber Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.57 |
| f100ASFx1LLFDepPort3Local Local device card port 1 Link Loss Forwarding
depends on port 3 Ethernet Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.58 |
| f100ASFx1LLFDepPort4Local Local device card port 1 Link Loss Forwarding
depends on port 4 Ethernet Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.59 |
| f100ASCardFPGAVerLocal Local device card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.6 |
| f100ASFx2LLFDepLogiLocal Local device card port 2 Link Loss Forwarding
depends boolean logic:
0:and
1:or | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.60 |
| f100ASFx2LLFDepPort1Local Local device card port 2 Link Loss Forwarding
depends on port 1 Fiber Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.61 |
| f100ASFx2LLFDepPort3Local Local device card port 2 Link Loss Forwarding
depends on port 3 Ethernet Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.62 |
| f100ASFx2LLFDepPort4Local Local device card port 2 Link Loss Forwarding
depends on port 4 Ethernet Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.63 |
| f100ASUtp1LLFDepLogiLocal Local device card port 3 Link Loss Forwarding
depends boolean logic:
0:and
1:or | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.64 |
| f100ASUtp1LLFDepPort1Local Local device card port 3 Link Loss Forwarding
depends on port 1 Fiber Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.65 |
| f100ASUtp1LLFDepPort2Local Local device card port 3 Link Loss Forwarding
depends on port 2 Fiber Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.66 |
| f100ASUtp2LLFDepLogiLocal Local device card port 4 Link Loss Forwarding
depends boolean logic:
0:and
1:or | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.67 |
| f100ASUtp2LLFDepPort1Local Local device card port 4 Link Loss Forwarding
depends on port 1 Fiber Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.68 |
| f100ASUtp2LLFDepPort2Local Local device card port 4 Link Loss Forwarding
depends on port 2 Fiber Rx link:
0:don't care
1:selected | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.69 |
| f100ASModelLocal Local frm220 f100AS Serial Type | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.7 |
| f100ASAdvanceFunsLocal Local device card Switch functions mode:
0:Normal
2:Port 1&2 Mirror
3:Port VLAN 1/3;2/4
4:Port 1&2 Redundancy
5:Static 802.1Q VLAN
6:Spanning Tree protocol
7:Static 802.1Q VLAN an… | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.70 |
| f100ASFx1InfoROM1Local Local device card port 1 INFORemoteOM information 1 valid:
0:Invalid
1:Valid | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.71 |
| f100ASFx1InfoROM2Local Local device card port 1 INFORemoteOM information 2 valid:
0:Invalid
1:Valid(replacing D/D function | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.72 |
| f100ASFx2InfoROM1Local Local device card port 2 INFORemoteOM information 1 valid:
0:Invalid
1:Valid | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.73 |
| f100ASFx2InfoROM2Local Local device card port 2 INFORemoteOM information 2 valid:
0:Invalid
1:Valid(replacing D/D function) | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.74 |
| f100ASFx1InfoSN1Local Local device card port 1 INFORemoteOM S/N 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.75 |
| f100ASFx1InfoSN2Local Local device card port 1 INFORemoteOM S/N 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.76 |
| f100ASFx2InfoSN1Local Local device card port 2 INFORemoteOM S/N 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.77 |
| f100ASFx2InfoSN2Local Local device card port 2 INFORemoteOM S/N 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.78 |
| f100ASFx1DDLocal Local device card fiber port 1 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.79 |
| f100ASFx1LinkLocal Local device card fiber port 1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.8 |
| f100ASFx1DDVendorLocal Local device card fiber port 1 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.80 |
| f100ASFx1DDPartNoLocal Local device card fiber port 1 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.81 |
| f100ASFx1DDFiberTypeLocal Local device card fiber port 1 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.82 |
| f100ASFx1DDWaveLenLocal Local device card fiber port 1 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.83 |
| f100ASFx1DDWaveLen2Local Local device card fiber port 1 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.84 |
| f100ASFx1DDLinkLenLocal Local device card fiber port 1 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.85 |
| f100ASFx1DDLenUnitLocal Local device card fiber port 1 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.86 |
| f100ASFx1DDStatusLocal Local device card fiber port 1 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.87 |
| f100ASFx1DDRxSensLocal Local device card fiber port 1 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.88 |
| f100ASFx1DDTxPWRLocal Local device card fiber port 1 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.89 |
| f100ASFx1OAMLoopedLocal Local device card fiber port 1 OAM looped:
0:Off
1:on | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.9 |
| f100ASFx1DDRxPWRLocal Local device card fiber port 1 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.90 |
| f100ASFx1DDTempLocal Local device card fiber port 1 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.91 |
| f100ASFx1DDPWRMarginLocal Local device card fiber port 1 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.92 |
| f100ASFx1DDPWRLossLocal Local device card fiber port 1 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.190.40.1.93 |
| f100ASFx2DDLocal Local device card fiber port 2 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.94 |
| f100ASFx2DDVendorLocal Local device card fiber port 2 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.95 |
| f100ASFx2DDPartNoLocal Local device card fiber port 2 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.96 |
| f100ASFx2DDFiberTypeLocal Local device card fiber port 2 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.190.40.1.97 |
| f100ASFx2DDWaveLenLocal Local device card fiber port 2 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.98 |
| f100ASFx2DDWaveLen2Local Local device card fiber port 2 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.190.40.1.99 |