f1000EDSFx2DDLinkLen
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.170.20.1.73
Object
column
SNMPv2-TCDisplayString
device card fiber port 2 D/D information: Link length
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.170.20.1.73- Type
- column
- Access
- readonly
- Status
- current
- Parent
- f1000EDSEntry
- Table
- f1000EDSTable
- Siblings
- 88
Values & Constraints
Type Constraints
range: 0..255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| f1000EDSChassisIndex A unique value for each local card.
It is the chassis location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.170.20.1.1 |
| f1000EDSFx1RemoPwrAb device card fiber port 1 Remote Power status:
0:Abnormal
1:OK | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.10 |
| f1000EDSFx2Link device card fiber port 2 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.11 |
| f1000EDSFx2FEF device card fiber port 2 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.12 |
| f1000EDSFx2RemoPwrAb device card fiber port 2 Remote Power status:
0:Abnormal
1:OK | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.13 |
| f1000EDSUtp1Link device card UTP port 3 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.14 |
| f1000EDSUtp1Nego device card UTP port 3 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.15 |
| f1000EDSUtp1Speed device card UTP port 3 speed status:
0:10 Base-T
1:100 Base-TX
2:1000 Base-TX | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.16 |
| f1000EDSUtp1Duplex device card UTP port 3 duplex status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.17 |
| f1000EDSUtp2Link device card UTP port 4 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.18 |
| f1000EDSUtp2Nego device card UTP port 4 negotiation status:
0:Manual
1:Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.19 |
| f1000EDSSlotIndex A unique value for each local card.
It is the slot location number. | column | Integer32 | .1.3.6.1.4.1.4756.20.170.20.1.2 |
| f1000EDSUtp2Speed device card UTP port 4 speed status:
0:10 Base-T
1:100 Base-TX
2:1000 Base-TX | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.20 |
| f1000EDSUtp2Duplex device card UTP port 4 duplex status:
0:Half duplex mode
1:Full duplex mode | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.21 |
| f1000EDSFx1IrlMode device card port 1 Ingress Rate Limit mode:
(Ingress data rate limit for priority 0 frames.)
0:No limit
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.22 |
| f1000EDSFx1IrlIndex device card port 1 Ingress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.23 |
| f1000EDSFx1ErlIndex device card port 1 Egress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.24 |
| f1000EDSFx2IrlMode device card port 2 Ingress Rate Limit mode:
(Ingress data rate limit for priority 0 frames.)
0:No limit
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.25 |
| f1000EDSFx2IrlIndex device card port 2 Ingress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.26 |
| f1000EDSFx2ErlIndex device card port 2 Egress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.27 |
| f1000EDSUtp1IrlMode device card port 3 Ingress Rate Limit mode:
(Ingress data rate limit for priority 0 frames.)
0:No limit
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.28 |
| f1000EDSUtp1IrlIndex device card port 3 Ingress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.29 |
| f1000EDSCardHWVer device card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.3 |
| f1000EDSUtp1ErlIndex device card port 3 Egress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.30 |
| f1000EDSUtp2IrlMode device card port 4 Ingress Rate Limit mode:
(Ingress data rate limit for priority 0 frames.)
0:No limit
1:limited | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.31 |
| f1000EDSUtp2IrlIndex device card port 4 Ingress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.32 |
| f1000EDSUtp2ErlIndex device card port 4 Egress Rate Limit index:
Index Limit Rate Index Limit Rate
0 Disable 16 1M
1 250M 17 960K
2 140M … | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.33 |
| f1000EDSDeviceActive device card active mode:
(It is read-only in local device.)
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.34 |
| f1000EDSDeviceReset Force local device card to reset mode:
0:Off
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.35 |
| f1000EDSFx1Active device fiber port 1 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.36 |
| f1000EDSFx2Active device fiber port 2 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.37 |
| f1000EDSUtp1Active device UTP port 3 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.38 |
| f1000EDSUtp2Active device UTP port 4 active mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.39 |
| f1000EDSCardFWVer device card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.4 |
| f1000EDSOperationMode device operation mode setting
0:Switch Mode
1:Port VLAN Mode | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.40 |
| f1000EDSLfpMode1 device card port 1 Link Fault Pass Through:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.41 |
| f1000EDSLfpMode2 device card port 2 Link Fault Pass Through:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.42 |
| f1000EDSFx1AlsMode1 device card port 1 Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.43 |
| f1000EDSFx2AlsMode2 device card port 2 Auto Laser Shutdown mode:
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.44 |
| f1000EDSClrRMONCnts Clear local device card RMON IN/OUT counters:
0:No action
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.45 |
| f1000EDSFx1InfoROM1 device card port 1 INFORemoteOM information 1 valid:
0:Invalid
1:Valid | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.46 |
| f1000EDSFx1InfoROM2 device card port 1 INFORemoteOM information 2 valid:
0:Invalid
1:Valid(replacing D/D function | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.47 |
| f1000EDSFx2InfoROM2 device card port 2 INFORemoteOM information 2 valid:
0:Invalid
1:Valid(replacing D/D function) | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.48 |
| f1000EDSFx1InfoSN1 device card port 1 INFORemoteOM S/N 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.49 |
| f1000EDSCardCPLDVer device card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.5 |
| f1000EDSFx1InfoSN2 device card port 1 INFORemoteOM S/N 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.50 |
| f1000EDSFx2InfoSN1 device card port 2 INFORemoteOM S/N 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.51 |
| f1000EDSFx2InfoSN2 device card port 2 INFORemoteOM S/N 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.52 |
| f1000EDSFx1DD device card fiber port 1 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.53 |
| f1000EDSFx1DDVendor device card fiber port 1 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.54 |
| f1000EDSFx1DDPartNo device card fiber port 1 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.55 |
| f1000EDSFx1DDFiberType device card fiber port 1 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.56 |
| f1000EDSFx1DDWaveLen device card fiber port 1 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.57 |
| f1000EDSFx1DDWaveLen2 device card fiber port 1 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.58 |
| f1000EDSFx1DDLinkLen device card fiber port 1 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.59 |
| f1000EDSCardFPGAVer device card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.6 |
| f1000EDSFx1DDLenUnit device card fiber port 1 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.60 |
| f1000EDSFx1DDStatus device card fiber port 1 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.61 |
| f1000EDSFx1DDRxSens device card fiber port 1 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.62 |
| f1000EDSFx1DDTxPWR device card fiber port 1 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.63 |
| f1000EDSFx1DDRxPWR device card fiber port 1 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.64 |
| f1000EDSFx1DDTemp device card fiber port 1 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.65 |
| f1000EDSFx1DDPWRMargin device card fiber port 1 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.170.20.1.66 |
| f1000EDSFx2DD device card fiber port 2 Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.67 |
| f1000EDSFx2DDVendor device card fiber port 2 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.68 |
| f1000EDSFx2DDPartNo device card fiber port 2 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.69 |
| f1000EDSModel frm220 f1000EDS Serial Type | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.7 |
| f1000EDSFx2DDFiberType device card fiber port 2 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.70 |
| f1000EDSFx2DDWaveLen device card fiber port 2 D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.71 |
| f1000EDSFx2DDWaveLen2 device card fiber port 2 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.72 |
| f1000EDSFx2DDLenUnit device card fiber port 2 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.74 |
| f1000EDSFx2DDStatus device card fiber port 2 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.75 |
| f1000EDSFx2DDRxSens device card fiber port 2 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.76 |
| f1000EDSFx2DDTxPWR device card fiber port 2 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.77 |
| f1000EDSFx2DDRxPWR device card fiber port 2 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.78 |
| f1000EDSFx2DDTemp device card fiber port 2 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.79 |
| f1000EDSFx1Link device card fiber port 1 link status:
0:Down
1:Up | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.8 |
| f1000EDSFx2DDPWRMargin device card fiber port 2 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.170.20.1.80 |
| f1000EDSFx1RMONIn device card port 1 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.81 |
| f1000EDSFx1RMONOut device card port 1 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.82 |
| f1000EDSFx2RMONIn device card port 2 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.83 |
| f1000EDSFx2RMONOut device card port 2 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.84 |
| f1000EDSUtp1RMONIn device card port 3 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.85 |
| f1000EDSUtp1RMONOut device card port 3 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.86 |
| f1000EDSUtp2RMONIn device card port 4 RMON IN counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.87 |
| f1000EDSUtp2RMONOut device card port 4 RMON OUT counter. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.170.20.1.88 |
| f1000EDSSetDefault device card set to default
0:OFF
1:Action | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.89 |
| f1000EDSFx1FEF device card fiber port 1 detected Far End Fault:
0:Off
1:Detected | column | Enumeration | .1.3.6.1.4.1.4756.20.170.20.1.9 |