eddIPInterface1VLANRemoteB
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.442.20.1.763
Object
column
Integer32
EDD Series card IP Interfaces: The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface. This field is only available for input when creating an new interface.
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.442.20.1.763- Type
- column
- Access
- readonly
- Status
- current
- Parent
- eddRemoteBEntry
- Table
- eddRemoteBTable
- Siblings
- 983
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eddChassisIndexRemoteB A unique value for each card.
It starts from 0 to 9 contiguously. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.1 |
| eddPort1DuplexstsRemoteB EDD Series card Port1 duplex status
0: Half
1: Full | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.10 |
| edduRingInst1rolestsRemoteB EDD Series card u-Ring Role status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.100 |
| edduRingInst1EastPortstsRemoteB EDD Series card u-Ring East port status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.101 |
| edduRingInst1EaststsRemoteB EDD Series card u-Ring East status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.102 |
| edduRingInst1EastEdgestsRemoteB EDD Series card u-Ring East edge status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.103 |
| edduRingInst1WestPortstsRemoteB EDD Series card u-Ring West edge status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.104 |
| edduRingInst1WeststsRemoteB EDD Series card u-Ring West status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.105 |
| edduRingInst1WestEdgestsRemoteB EDD Series card u-Ring West status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.106 |
| edduRingInst1healthystsRemoteB EDD Series card u-Ring healthy status
None
Fine
Fault | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.107 |
| edduRingInst2IDstsRemoteB EDD Series card u-Ring Instance2 ID status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.108 |
| edduRingInst2typestsRemoteB EDD Series card u-Ring Type status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.109 |
| eddPort1RxPausestsRemoteB EDD Series card Port1 rx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.11 |
| edduRingInst2rolestsRemoteB EDD Series card u-Ring Role status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.110 |
| edduRingInst2EastPortstsRemoteB EDD Series card u-Ring East port status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.111 |
| edduRingInst2EaststsRemoteB EDD Series card u-Ring East status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.112 |
| edduRingInst2EastEdgestsRemoteB EDD Series card u-Ring East edge status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.113 |
| edduRingInst2WestPortstsRemoteB EDD Series card u-Ring West edge status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.114 |
| edduRingInst2WeststsRemoteB EDD Series card u-Ring West status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.115 |
| edduRingInst2WestEdgestsRemoteB EDD Series card u-Ring West status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.116 |
| edduRingInst2healthystsRemoteB EDD Series card u-Ring healthy status
None
Fine
Fault | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.117 |
| eddDeviceActiveRemoteB EDD Series card u-Ring device active
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.118 |
| eddFx1DDRemoteB EDD Series card fiber port Digital Diagnostic
function:
0:No
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.119 |
| eddPort1TxPausestsRemoteB EDD Series card Port1 tx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.12 |
| eddFx1DDVendorRemoteB EDD Series card fiber port D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.120 |
| eddFx1DDPartNoRemoteB EDD Series card fiber port D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.121 |
| eddFx1DDFiberTypeRemoteB EDD Series card fiber port D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.122 |
| eddFx1DDWaveLenRemoteB EDD Series card fiber port D/D information:
Wave length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.123 |
| eddFx1DDWaveLen2RemoteB EDD Series card fiber port D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.124 |
| eddFx1DDLinkLenRemoteB EDD Series card fiber port D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.125 |
| eddFx1DDLenUnitRemoteB EDD Series card fiber port D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.126 |
| eddFx1DDStatusRemoteB EDD Series card fiber port D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.127 |
| eddFx1DDRxSensRemoteB EDD Series card fiber port D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.128 |
| eddFx1DDTxPWRRemoteB EDD Series card fiber port D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.129 |
| eddPort2LinkstsRemoteB EDD Series card Port2 link status:
0:Link down
1:Link up | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.13 |
| eddFx1DDRxPWRRemoteB EDD Series card fiber port D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.130 |
| eddFx1DDTempRemoteB EDD Series card fiber port D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.131 |
| eddFx1DDPWRMarginRemoteB EDD Series card fiber port D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.442.20.1.132 |
| eddFx1DDPWRLossRemoteB EDD Series card fiber port D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.442.20.1.133 |
| eddFx2DDRemoteB EDD Series card fiber2 Digital Diagnostic
function:
0:NO
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.134 |
| eddFx2DDVendorRemoteB EDD Series card fiber2 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.135 |
| eddFx2DDPartNoRemoteB EDD Series card fiber2 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.136 |
| eddFx2DDFiberTypeRemoteB EDD Series card fiber2 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.137 |
| eddFx2DDWaveLenRemoteB EDD Series card fiber2 D/D information:
Wave length 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.138 |
| eddFx2DDWaveLen2RemoteB EDD Series card fiber2 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.139 |
| eddPort2SpeedstsRemoteB EDD Series card Port2 speed status
10Base-T
100Base-Tx
1000Base-Tx
2.5G | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.14 |
| eddFx2DDLinkLenRemoteB EDD Series card fiber2 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.140 |
| eddFx2DDLenUnitRemoteB EDD Series card fiber2 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.141 |
| eddFx2DDStatusRemoteB EDD Series card fiber2 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.142 |
| eddFx2DDRxSensRemoteB EDD Series card fiber2 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.143 |
| eddFx2DDTxPWRRemoteB EDD Series card fiber2 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.144 |
| eddFx2DDRxPWRRemoteB EDD Series card fiber2 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.145 |
| eddFx2DDTempRemoteB EDD Series card fiber2 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.146 |
| eddFx2DDPWRMarginRemoteB EDD Series card fiber2 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.442.20.1.147 |
| eddFx2DDPWRLossRemoteB EDD Series card fiber2 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.442.20.1.148 |
| eddFx3DDRemoteB EDD Series card fiber3 Digital Diagnostic
function:
0:NO
1:Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.149 |
| eddPort2DuplexstsRemoteB EDD Series card Port2 duplex status
0: Half
1: Full | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.15 |
| eddFx3DDVendorRemoteB EDD Series card fiber3 D/D information:
Vendor name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.150 |
| eddFx3DDPartNoRemoteB EDD Series card fiber32 D/D information:
Vendor part number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.151 |
| eddFx3DDFiberTypeRemoteB EDD Series card fiber3 D/D information:
Fiber Type | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.152 |
| eddFx3DDWaveLenRemoteB EDD Series card fiber3 D/D information:
Wave length 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.153 |
| eddFx3DDWaveLen2RemoteB EDD Series card fiber3 D/D information:
Wave length 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.154 |
| eddFx3DDLinkLenRemoteB EDD Series card fiber3 D/D information:
Link length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.155 |
| eddFx3DDLenUnitRemoteB EDD Series card fiber3 D/D information:
Length Unit | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.156 |
| eddFx3DDStatusRemoteB EDD Series card fiber3 D/D information:
Status Support | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.157 |
| eddFx3DDRxSensRemoteB EDD Series card fiber3 D/D information:
Rx Sensitivity | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.158 |
| eddFx3DDTxPWRRemoteB EDD Series card fiber3 D/D information:
Tx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.159 |
| eddPort2RxPausestsRemoteB EDD Series card Port2 rx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.16 |
| eddFx3DDRxPWRRemoteB EDD Series card fiber3 D/D information:
Rx power | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.160 |
| eddFx3DDTempRemoteB EDD Series card fiber3 D/D information:
Temperature in degree C | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.161 |
| eddFx3DDPWRMarginRemoteB EDD Series card fiber3 D/D information:
Power margin | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.442.20.1.162 |
| eddFx3DDPWRLossRemoteB EDD Series card fiber3 D/D information:
Power loss | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.4756.20.442.20.1.163 |
| eddTestRemoteB EDD Series card test led sts:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.164 |
| eddClearPortCounterRemoteB EDD Series card clear port counter:
0: Off
1: Action | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.165 |
| eddAggrSourceMACAddrRemoteB EDD Series card Aggregation Mode Configuration:
Source MAC Address
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.166 |
| eddAggrDestinationMACAddrRemoteB EDD Series card Aggregation Mode Configuration:
Destination MAC Address
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.167 |
| eddAggrIPAddrRemoteB EDD Series card Aggregation Mode Configuration:
IP Address
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.168 |
| eddAggrTCPUDPPortNumRemoteB EDD Series card Aggregation Mode Configuration:
TCP/UDP Port Number
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.169 |
| eddPort2TxPausestsRemoteB EDD Series card Port2 tx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.17 |
| eddAggrGroupPort1ConfRemoteB EDD Series card Aggregation Group Port1 Configuration:
0: Normal
1: ID1
2: ID2 | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.170 |
| eddAggrGroupPort2ConfRemoteB EDD Series card Aggregation Group Port2 Configuration:
0: Normal
1: ID1
2: ID2 | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.171 |
| eddAggrGroupPort3ConfRemoteB EDD Series card Aggregation Group Port3 Configuration:
0: Normal
1: ID1
2: ID2 | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.172 |
| eddAggrGroupPort4ConfRemoteB EDD Series card Aggregation Group Port4 Configuration:
0: Normal
1: ID1
2: ID2 | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.173 |
| eddPort1LACPEnabledRemoteB EDD Series card Port1 LACP Enabled:
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.174 |
| eddPort1LACPKEYRemoteB EDD Series card Port1 LACP Key value:
The Key value incurred by the port, range 0-65535.The value of 0 means auto. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.175 |
| eddPort1LACPRoleRemoteB EDD Series card Port1 LACP Role:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.176 |
| eddPort1LACPTimeOutRemoteB EDD Series card Port1 LACP Time out:
0: Slow
1: Fast | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.177 |
| eddPort1LACPPrioRemoteB EDD Series card Port1 LACP priority:
The Key value incurred by the port, range 1-65535. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.178 |
| eddPort2LACPEnabledRemoteB EDD Series card Port2 LACP Enabled:
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.179 |
| eddPort3LinkstsRemoteB EDD Series card Port3 link status:
0:Link down
1:Link up | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.18 |
| eddPort2LACPKEYRemoteB EDD Series card Port2 LACP Key value:
The Key value incurred by the port, range 0-65535.The value of 0 means auto. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.180 |
| eddPort2LACPRoleRemoteB EDD Series card Port2 LACP Role:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.181 |
| eddPort2LACPTimeOutRemoteB EDD Series card Port2 LACP Time out:
0: Slow
1: Fast | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.182 |
| eddPort2LACPPrioRemoteB EDD Series card Port2 LACP priority:
The Key value incurred by the port, range 1-65535. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.183 |
| eddPort3LACPEnabledRemoteB EDD Series card Port3 LACP Enabled:
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.184 |
| eddPort3LACPKEYRemoteB EDD Series card Port3 LACP Key value:
The Key value incurred by the port, range 0-65535.The value of 0 means auto. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.185 |
| eddPort3LACPRoleRemoteB EDD Series card Port3 LACP Role:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.186 |
| eddPort3LACPTimeOutRemoteB EDD Series card Port3 LACP Time out:
0: Slow
1: Fast | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.187 |
| eddPort3LACPPrioRemoteB EDD Series card Port3 LACP priority:
The Key value incurred by the port, range 1-65535. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.188 |
| eddPort4LACPEnabledRemoteB EDD Series card Port4 LACP Enabled:
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.189 |
| eddPort3SpeedstsRemoteB EDD Series card Port3 speed status
10Base-T
100Base-Tx
1000Base-Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.19 |
| eddPort4LACPKEYRemoteB EDD Series card Port4 LACP Key value:
The Key value incurred by the port, range 0-65535.The value of 0 means auto. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.190 |
| eddPort4LACPRoleRemoteB EDD Series card Port4 LACP Role:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.191 |
| eddPort4LACPTimeOutRemoteB EDD Series card Port4 LACP Time out:
0: Slow
1: Fast | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.192 |
| eddPort4LACPPrioRemoteB EDD Series card Port4 LACP priority:
The Key value incurred by the port, range 1-65535. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.193 |
| eddPort1LACPstsRemoteB EDD Series card Port1 LACP status:
0: No
1: Yes
2: Standby | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.194 |
| eddPort1LACPKEYstsRemoteB EDD Series card Port1 LACP status:
Key | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.195 |
| eddPort1LACPAggrIDstsRemoteB EDD Series card Port1 LACP status:
Aggr ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.196 |
| eddPort1LACPParnterSysIDstsRemoteB EDD Series card Port1 LACP status:
Parnter System ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.197 |
| eddPort1LACPParnterPortstsRemoteB EDD Series card Port1 LACP status:
Parnter Port Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.198 |
| eddPort1LACPParnterProistsRemoteB EDD Series card Port1 LACP status:
Parnter Priority | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.199 |
| eddSlotIndexRemoteB A unique value for each card.
It starts from 1 to 20 contiguously. | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.2 |
| eddPort3DuplexstsRemoteB EDD Series card Port3 duplex status
0: Half
1: Full | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.20 |
| eddPort2LACPstsRemoteB EDD Series card Port2 LACP status:
0: No
1: Yes
2: Standby | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.200 |
| eddPort2LACPKEYstsRemoteB EDD Series card Port2 LACP status:
Key | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.201 |
| eddPort2LACPAggrIDstsRemoteB EDD Series card Port2 LACP status:
Aggr ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.202 |
| eddPort2LACPParnterSysIDstsRemoteB EDD Series card Port2 LACP status:
Parnter System ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.203 |
| eddPort2LACPParnterPortstsRemoteB EDD Series card Port2 LACP status:
Parnter Port Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.204 |
| eddPort2LACPParnterProistsRemoteB EDD Series card Port2 LACP status:
Parnter Priority | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.205 |
| eddPort3LACPstsRemoteB EDD Series card Port3 LACP status:
0: No
1: Yes
2: Standby | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.206 |
| eddPort3LACPKEYstsRemoteB EDD Series card Port3 LACP status:
Key | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.207 |
| eddPort3LACPAggrIDstsRemoteB EDD Series card Port3 LACP status:
Aggr ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.208 |
| eddPort3LACPParnterSysIDstsRemoteB EDD Series card Port3 LACP status:
Parnter System ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.209 |
| eddPort3RxPausestsRemoteB EDD Series card Port3 rx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.21 |
| eddPort3LACPParnterPortstsRemoteB EDD Series card Port3 LACP status:
Parnter Port Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.210 |
| eddPort3LACPParnterProistsRemoteB EDD Series card Port3 LACP status:
Parnter Priority | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.211 |
| eddPort4LACPstsRemoteB EDD Series card Port4 LACP status:
0: No
1: Yes
2: Standby | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.212 |
| eddPort4LACPKEYstsRemoteB EDD Series card Port4 LACP status:
Key | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.213 |
| eddPort4LACPAggrIDstsRemoteB EDD Series card Port4 LACP status:
Aggr ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.214 |
| eddPort4LACPParnterSysIDstsRemoteB EDD Series card Port4 LACP status:
Parnter System ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.215 |
| eddPort4LACPParnterPortstsRemoteB EDD Series card Port4 LACP status:
Parnter Port Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.216 |
| eddPort4LACPParnterProistsRemoteB EDD Series card Port4 LACP status:
Parnter Priority | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.217 |
| eddOAMPort1EnableRemoteB EDD Series card Port1 OAM:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.218 |
| eddOAMPort1ModeRemoteB EDD Series card Port1 OAM:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.219 |
| eddPort3TxPausestsRemoteB EDD Series card Port3 tx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.22 |
| eddOAMPort1LoopBackRemoteB EDD Series card Port1 OAM LoopBack:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.220 |
| eddOAMPort1LinkMonitorRemoteB EDD Series card Port1 OAM Link Monitor:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.221 |
| eddOAMPort1MIBRetrievalRemoteB EDD Series card Port1 OAM MIB Retrieval:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.222 |
| eddOAMPort1LoopBackOPRemoteB EDD Series card Port1 OAM LoopBack operation:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.223 |
| eddOAMPort2EnableRemoteB EDD Series card Port2 OAM:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.224 |
| eddOAMPort2ModeRemoteB EDD Series card Port2 OAM:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.225 |
| eddOAMPort2LoopBackRemoteB EDD Series card Port2 OAM LoopBack:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.226 |
| eddOAMPort2LinkMonitorRemoteB EDD Series card Port2 OAM Link Monitor:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.227 |
| eddOAMPort2MIBRetrievalRemoteB EDD Series card Port2 OAM MIB Retrieval:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.228 |
| eddOAMPort2LoopBackOPRemoteB EDD Series card Port2 OAM LoopBack operation:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.229 |
| eddPort4LinkstsRemoteB EDD Series card Port4 link status:
0:Link down
1:Link up | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.23 |
| eddOAMPort3EnableRemoteB EDD Series card Port3 OAM:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.230 |
| eddOAMPort3ModeRemoteB EDD Series card Port3 OAM:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.231 |
| eddOAMPort3LoopBackRemoteB EDD Series card Port3 OAM:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.232 |
| eddOAMPort3LinkMonitorRemoteB EDD Series card Port3 OAM Link Monitor:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.233 |
| eddOAMPort3MIBRetrievalRemoteB EDD Series card Port3 OAM MIB Retrieval:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.234 |
| eddOAMPort3LoopBackOPRemoteB EDD Series card Port3 OAM LoopBack operation:
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.235 |
| eddOAMPort4EnableRemoteB EDD Series card Port4 OAM:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.236 |
| eddOAMPort4ModeRemoteB EDD Series card Port4 OAM:
0: Passive
1: Active | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.237 |
| eddOAMPort4LoopBackRemoteB EDD Series card Port4 OAM:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.238 |
| eddOAMPort4LinkMonitorRemoteB EDD Series card Port4 OAM Link Monitor:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.239 |
| eddPort4SpeedstsRemoteB EDD Series card Port4 speed status
10Base-T
100Base-Tx
1000Base-Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.24 |
| eddOAMPort4MIBRetrievalRemoteB EDD Series card Port4 OAM MIB Retrieval:
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.240 |
| eddOAMPort4LoopBackOPRemoteB EDD Series card Port4 OAM LoopBack operation:
0: On
1: Off | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.241 |
| eddPort1EFEErrorWindowRemoteB EDD Series card Port1 Link Event Configuration:
Error Frame Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.242 |
| eddPort1EFEErrorThresholdRemoteB EDD Series card Port1 Link Event Configuration:
Error Frame Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.243 |
| eddPort1SPEEErrorWindowRemoteB EDD Series card Port1 Link Event Configuration:
Symbol Period Error Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.244 |
| eddPort1SPEEErrorThresholdRemoteB EDD Series card Port1 Link Event Configuration:
Symbol Period Error Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.245 |
| eddPort1SSEErrorWindowRemoteB EDD Series card Port1 Link Event Configuration:
Seconds Summary Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.246 |
| eddPort1SSEErrorThresholdRemoteB EDD Series card Port1 Link Event Configuration:
Seconds Summary Event - Error Threshold | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.247 |
| eddPort2EFEErrorWindowRemoteB EDD Series card Port2 Link Event Configuration:
Error Frame Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.248 |
| eddPort2EFEErrorThresholdRemoteB EDD Series card Port2 Link Event Configuration:
Error Frame Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.249 |
| eddPort4DuplexstsRemoteB EDD Series card Port4 duplex status
0: Half
1: Full | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.25 |
| eddPort2SPEEErrorWindowRemoteB EDD Series card Port2 Link Event Configuration:
Symbol Period Error Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.250 |
| eddPort2SPEEErrorThresholdRemoteB EDD Series card Port2 Link Event Configuration:
Symbol Period Error Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.251 |
| eddPort2SSEErrorWindowRemoteB EDD Series card Port2 Link Event Configuration:
Seconds Summary Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.252 |
| eddPort2SSEErrorThresholdRemoteB EDD Series card Port2 Link Event Configuration:
Seconds Summary Event - Error Threshold | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.253 |
| eddPort3EFEErrorWindowRemoteB EDD Series card Port3 Link Event Configuration:
Error Frame Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.254 |
| eddPort3EFEErrorThresholdRemoteB EDD Series card Port3 Link Event Configuration:
Error Frame Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.255 |
| eddPort3SPEEErrorWindowRemoteB EDD Series card Port3 Link Event Configuration:
Symbol Period Error Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.256 |
| eddPort3SPEEErrorThresholdRemoteB EDD Series card Port3 Link Event Configuration:
Symbol Period Error Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.257 |
| eddPort3SSEErrorWindowRemoteB EDD Series card Port3 Link Event Configuration:
Seconds Summary Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.258 |
| eddPort3SSEErrorThresholdRemoteB EDD Series card Port3 Link Event Configuration:
Seconds Summary Event - Error Threshold | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.259 |
| eddPort4RxPausestsRemoteB EDD Series card Port4 rx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.26 |
| eddPort4EFEErrorWindowRemoteB EDD Series card Port4 Link Event Configuration:
Error Frame Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.260 |
| eddPort4EFEErrorThresholdRemoteB EDD Series card Port4 Link Event Configuration:
Error Frame Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.261 |
| eddPort4SPEEErrorWindowRemoteB EDD Series card Port4 Link Event Configuration:
Symbol Period Error Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.262 |
| eddPort4SPEEErrorThresholdRemoteB EDD Series card Port4 Link Event Configuration:
Symbol Period Error Event - Error Threshold | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.263 |
| eddPort4SSEErrorWindowRemoteB EDD Series card Port4 Link Event Configuration:
Seconds Summary Event - Error Window | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.264 |
| eddPort4SSEErrorThresholdRemoteB EDD Series card Port4 Link Event Configuration:
Seconds Summary Event - Error Threshold | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.265 |
| eddPort1RxOAMInfoPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.266 |
| eddPort1RxUniqueErrorEventRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.267 |
| eddPort1RxDuplicateErrorEventRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.268 |
| eddPort1RxLoopBackControlRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.269 |
| eddPort4TxPausestsRemoteB EDD Series card Port4 tx pause status
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.27 |
| eddPort1RxVariableRequestRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.270 |
| eddPort1RxVariableResponseRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.271 |
| eddPort1RxOrgSpecificPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.272 |
| eddPort1RxUnsupportedCodesRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.273 |
| eddPort1RxLinkFaultPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.274 |
| eddPort1RxDyingGaspRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.275 |
| eddPort1RxCriticalEventPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.276 |
| eddPort1TxOAMInfoPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.277 |
| eddPort1TxUniqueErrorEventRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.278 |
| eddPort1TxDuplicateErrorEventRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.279 |
| eddPort1SpeedConfRemoteB EDD Series card Port1 speed config
0: disable
1: auto
2: 100M FDX
3: 1G FDX
4: 2.5G FDX | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.28 |
| eddPort1TxLoopBackControlRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.280 |
| eddPort1TxVariableRequestRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.281 |
| eddPort1TxVariableResponseRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.282 |
| eddPort1TxOrgSpecificPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.283 |
| eddPort1TxUnsupportedCodesRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.284 |
| eddPort1TxLinkFaultPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.285 |
| eddPort1TxDyingGaspRemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.286 |
| eddPort1TxCriticalEventPDURemoteB EDD Series card Port1 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.287 |
| eddPort2RxOAMInfoPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.288 |
| eddPort2RxUniqueErrorEventRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.289 |
| eddPort1flowConrolRemoteB EDD Series card Port1 flow control config
0: no
1: yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.29 |
| eddPort2RxDuplicateErrorEventRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.290 |
| eddPort2RxLoopBackControlRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.291 |
| eddPort2RxVariableRequestRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.292 |
| eddPort2RxVariableResponseRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.293 |
| eddPort2RxOrgSpecificPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.294 |
| eddPort2RxUnsupportedCodesRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.295 |
| eddPort2RxLinkFaultPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.296 |
| eddPort2RxDyingGaspRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.297 |
| eddPort2RxCriticalEventPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.298 |
| eddPort2TxOAMInfoPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.299 |
| eddCardHWVerRemoteB EDD Series card hardware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.3 |
| eddPort1MaxFrameRemoteB EDD Series card Port1 max frame config | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.30 |
| eddPort2TxUniqueErrorEventRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.300 |
| eddPort2TxDuplicateErrorEventRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.301 |
| eddPort2TxLoopBackControlRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.302 |
| eddPort2TxVariableRequestRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.303 |
| eddPort2TxVariableResponseRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.304 |
| eddPort2TxOrgSpecificPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.305 |
| eddPort2TxUnsupportedCodesRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.306 |
| eddPort2TxLinkFaultPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.307 |
| eddPort2TxDyingGaspRemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.308 |
| eddPort2TxCriticalEventPDURemoteB EDD Series card Port2 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.309 |
| eddPort2SpeedConfRemoteB EDD Series card Port2 speed config
0: disable
1: auto
2: 100M FDX
3: 1G FDX
4: 2.5G FDX | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.31 |
| eddPort3RxOAMInfoPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.310 |
| eddPort3RxUniqueErrorEventRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.311 |
| eddPort3RxDuplicateErrorEventRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.312 |
| eddPort3RxLoopBackControlRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.313 |
| eddPort3RxVariableRequestRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.314 |
| eddPort3RxVariableResponseRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.315 |
| eddPort3RxOrgSpecificPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.316 |
| eddPort3RxUnsupportedCodesRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.317 |
| eddPort3RxLinkFaultPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.318 |
| eddPort3RxDyingGaspRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.319 |
| eddPort2flowConrolRemoteB EDD Series card Port2 flow control config
0: no
1: yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.32 |
| eddPort3RxCriticalEventPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.320 |
| eddPort3TxOAMInfoPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.321 |
| eddPort3TxUniqueErrorEventRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.322 |
| eddPort3TxDuplicateErrorEventRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.323 |
| eddPort3TxLoopBackControlRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.324 |
| eddPort3TxVariableRequestRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.325 |
| eddPort3TxVariableResponseRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.326 |
| eddPort3TxOrgSpecificPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.327 |
| eddPort3TxUnsupportedCodesRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.328 |
| eddPort3TxLinkFaultPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.329 |
| eddPort2MaxFrameRemoteB EDD Series card Port2 max frame config | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.33 |
| eddPort3TxDyingGaspRemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.330 |
| eddPort3TxCriticalEventPDURemoteB EDD Series card Port3 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.331 |
| eddPort4RxOAMInfoPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.332 |
| eddPort4RxUniqueErrorEventRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.333 |
| eddPort4RxDuplicateErrorEventRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.334 |
| eddPort4RxLoopBackControlRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.335 |
| eddPort4RxVariableRequestRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.336 |
| eddPort4RxVariableResponseRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.337 |
| eddPort4RxOrgSpecificPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.338 |
| eddPort4RxUnsupportedCodesRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.339 |
| eddPort3SpeedConfRemoteB EDD Series card Port3 speed config
0: disable
1: auto
2: 10M HDX
3: 10M FDX
4: 100M HDX
5: 100M FDX
6: 1G FDX | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.34 |
| eddPort4RxLinkFaultPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.340 |
| eddPort4RxDyingGaspRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.341 |
| eddPort4RxCriticalEventPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Rx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.342 |
| eddPort4TxOAMInfoPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx OAM Information PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.343 |
| eddPort4TxUniqueErrorEventRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Unique Error Event Notificatio | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.344 |
| eddPort4TxDuplicateErrorEventRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Duplicate Error Event Notification | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.345 |
| eddPort4TxLoopBackControlRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Loopback Control | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.346 |
| eddPort4TxVariableRequestRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Variable Request | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.347 |
| eddPort4TxVariableResponseRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Variable Response | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.348 |
| eddPort4TxOrgSpecificPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Org Specific PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.349 |
| eddPort3flowConrolRemoteB EDD Series card Port3 flow control config
0: no
1: yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.35 |
| eddPort4TxUnsupportedCodesRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Unsupported Codes | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.350 |
| eddPort4TxLinkFaultPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Link Fault PDU's | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.351 |
| eddPort4TxDyingGaspRemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.352 |
| eddPort4TxCriticalEventPDURemoteB EDD Series card Port4 Detailed Link OAM Statistics:
Tx Dying Gasp | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.4756.20.442.20.1.353 |
| eddPort1PDUPermisionRemoteB EDD Series card Detailed Link OAM Status for Port 1:
PDU Permission | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.354 |
| eddPort1DiscoveryStateRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.355 |
| eddPort1PeerMACAddrRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.356 |
| eddPort1LocalModeRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.357 |
| eddPort1LocalUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.358 |
| eddPort1LocalRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.359 |
| eddPort3MaxFrameRemoteB EDD Series card Port3 max frame config | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.36 |
| eddPort1LocalLMRemoteB EDD Series card Detailed Link OAM Status for Port 1:
RemoteB: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.360 |
| eddPort1LocalMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.361 |
| eddPort1LocalMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.362 |
| eddPort1LocalMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.363 |
| eddPort1LocalParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.364 |
| eddPort1LocalOUIRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.365 |
| eddPort1LocalPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Local: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.366 |
| eddPort1PeerModeRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.367 |
| eddPort1PeerUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.368 |
| eddPort1PeerRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.369 |
| eddPort3CollisionModeRemoteB EDD Series card Port3 collision mode config.(MSW202 only)
0: Discard
1: Restart | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.37 |
| eddPort1PeerLMRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.370 |
| eddPort1PeerMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.371 |
| eddPort1PeerMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.372 |
| eddPort1PeerMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.373 |
| eddPort1PeerParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.374 |
| eddPort1PeerOUIRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.375 |
| eddPort1PeerPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 1:
Peer: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.376 |
| eddPort2PDUPermisionRemoteB EDD Series card Detailed Link OAM Status for Port 2:
PDU Permission | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.377 |
| eddPort2DiscoveryStateRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.378 |
| eddPort2PeerMACAddrRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.379 |
| eddPort4SpeedConfRemoteB EDD Series card Port4 speed config
0: disable
1: auto
2: 10M HDX
3: 10M FDX
4: 100M HDX
5: 100M FDX
6: 1G FDX | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.38 |
| eddPort2LocalModeRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.380 |
| eddPort2LocalUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.381 |
| eddPort2LocalRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.382 |
| eddPort2LocalLMRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.383 |
| eddPort2LocalMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.384 |
| eddPort2LocalMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.385 |
| eddPort2LocalMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.386 |
| eddPort2LocalParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.387 |
| eddPort2LocalOUIRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.388 |
| eddPort2LocalPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Local: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.389 |
| eddPort4flowConrolRemoteB EDD Series card Port4 flow control config
0: no
1: yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.39 |
| eddPort2PeerModeRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.390 |
| eddPort2PeerUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.391 |
| eddPort2PeerRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.392 |
| eddPort2PeerLMRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.393 |
| eddPort2PeerMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.394 |
| eddPort2PeerMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.395 |
| eddPort2PeerMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.396 |
| eddPort2PeerParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.397 |
| eddPort2PeerOUIRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.398 |
| eddPort2PeerPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 2:
Peer: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.399 |
| eddCardFWVerRemoteB EDD Series card firmware version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.4 |
| eddPort4MaxFrameRemoteB EDD Series card Port4 max frame config | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.40 |
| eddPort3PDUPermisionRemoteB EDD Series card Detailed Link OAM Status for Port 3:
PDU Permission | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.400 |
| eddPort3DiscoveryStateRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.401 |
| eddPort3PeerMACAddrRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.402 |
| eddPort3LocalModeRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.403 |
| eddPort3LocalUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.404 |
| eddPort3LocalRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.405 |
| eddPort3LocalLMRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.406 |
| eddPort3LocalMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.407 |
| eddPort3LocalMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.408 |
| eddPort3LocalMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.409 |
| eddPort4CollisionModeRemoteB EDD Series card Port4 collision mode config
0: Discard
1: Restart | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.41 |
| eddPort3LocalParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.410 |
| eddPort3LocalOUIRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.411 |
| eddPort3LocalPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Local: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.412 |
| eddPort3PeerModeRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.413 |
| eddPort3PeerUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.414 |
| eddPort3PeerRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.415 |
| eddPort3PeerLMRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.416 |
| eddPort3PeerMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.417 |
| eddPort3PeerMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.418 |
| eddPort3PeerMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.419 |
| eddSaveStartupCongRemoteB EDD Series card save start-up config
0: OFF
1: Action | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.42 |
| eddPort3PeerParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.420 |
| eddPort3PeerOUIRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.421 |
| eddPort3PeerPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 3:
Peer: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.422 |
| eddPort4PDUPermisionRemoteB EDD Series card Detailed Link OAM Status for Port 4:
PDU Permission | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.423 |
| eddPort4DiscoveryStateRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.424 |
| eddPort4PeerMACAddrRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Discovery State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.425 |
| eddPort4LocalModeRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.426 |
| eddPort4LocalUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.427 |
| eddPort4LocalRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.428 |
| eddPort4LocalLMRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.429 |
| eddPortResetRemoteB EDD Series card port reset
0: OFF
1: Action | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.43 |
| eddPort4LocalMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.430 |
| eddPort4LocalMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.431 |
| eddPort4LocalMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.432 |
| eddPort4LocalParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.433 |
| eddPort4LocalOUIRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.434 |
| eddPort4LocalPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Local: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.435 |
| eddPort4PeerModeRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Mode | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.436 |
| eddPort4PeerUnOperationRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Unidirectional Operation Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.437 |
| eddPort4PeerRemoteLbRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Remote Loopback Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.438 |
| eddPort4PeerLMRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Link Monitoring Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.439 |
| eddSetDefaultRemoteB EDD Series card set to default config
0: OFF
1: Action | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.44 |
| eddPort4PeerMIBRetrievalRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: MIB Retrieval Support | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.440 |
| eddPort4PeerMTUSizeRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: MTU Size | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.441 |
| eddPort4PeerMultiStateRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.442 |
| eddPort4PeerParserStateRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Multiplexer State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.443 |
| eddPort4PeerOUIRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: Organizational Unique Identification | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.444 |
| eddPort4PeerPDURevRemoteB EDD Series card Detailed Link OAM Status for Port 4:
Peer: PDU Revision | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.445 |
| eddCLEAROAMCOUNTERRemoteB EDD Series card Clear OAM Counter:
0: Off
1: Action | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.446 |
| eddLoopProtectionEnableRemoteB EDD Series card Loop Protection Configuration:
General Settings - Enable Loop Protection
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.447 |
| eddLoopProtectionTxTimeRemoteB EDD Series card Loop Protection Configuration:
General Settings - Transmission Time | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.448 |
| eddLoopProtectionShutdownTimeRemoteB EDD Series card Loop Protection Configuration:
General Settings - Shutdown Time | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.449 |
| eddMuxModeRemoteB EDD Series card Mux mode (MX210 only)
0: Disable
1: Switch
2: Isolate
3: VLAN | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.45 |
| eddLoopProtectionPort1EnabledRemoteB EDD Series card Loop Protection Configuration for Port 1:
Port Configuration - Enable
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.450 |
| eddLoopProtectionPort1ActionRemoteB EDD Series card Loop Protection Configuration for Port 1:
Port Configuration - Action
0: Shutdown Port
1: Shutdown Port And Log
2: Log Only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.451 |
| eddLoopProtectionPort1TxModeRemoteB EDD Series card Loop Protection Configuration for Port 1:
Port Configuration - Tx Mode
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.452 |
| eddLoopProtectionPort2EnabledRemoteB EDD Series card Loop Protection Configuration for Port 2:
Port Configuration - Enable
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.453 |
| eddLoopProtectionPort2ActionRemoteB EDD Series card Loop Protection Configuration for Port 2:
Port Configuration - Action
0: Shutdown Port
1: Shutdown Port And Log
2: Log Only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.454 |
| eddLoopProtectionPort2TxModeRemoteB EDD Series card Loop Protection Configuration for Port 2:
Port Configuration - Tx Mode
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.455 |
| eddLoopProtectionPort3EnabledRemoteB EDD Series card Loop Protection Configuration for Port 3:
Port Configuration - Enable
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.456 |
| eddLoopProtectionPort3ActionRemoteB EDD Series card Loop Protection Configuration for Port 3:
Port Configuration - Action
0: Shutdown Port
1: Shutdown Port And Log
2: Log Only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.457 |
| eddLoopProtectionPort3TxModeRemoteB EDD Series card Loop Protection Configuration for Port 3:
Port Configuration - Tx Mode
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.458 |
| eddLoopProtectionPort4EnabledRemoteB EDD Series card Loop Protection Configuration for Port 4:
Port Configuration - Enable
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.459 |
| eddPort1PacketsRxRemoteB EDD Series card port1 traffic overview::
Packets Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.46 |
| eddLoopProtectionPort4ActionRemoteB EDD Series card Loop Protection Configuration for Port 4:
Port Configuration - Action
0: Shutdown Port
1: Shutdown Port And Log
2: Log Only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.460 |
| eddLoopProtectionPort4TxModeRemoteB EDD Series card Loop Protection Configuration for Port 41:
Port Configuration - Tx Mode
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.461 |
| eddLoopProtectionPort1ActionStsRemoteB EDD Series card Loop Protection Status for Port 1:
Action | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.462 |
| eddLoopProtectionPort1TransStsRemoteB EDD Series card Loop Protection Status for Port 1:
Transmit | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.463 |
| eddLoopProtectionPort1LoopsStsRemoteB EDD Series card Loop Protection Status for Port 1:
Loops | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.464 |
| eddLoopProtectionPort1StatusRemoteB EDD Series card Loop Protection Status for Port 1:
Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.465 |
| eddLoopProtectionPort1LoopStsRemoteB EDD Series card Loop Protection Status for Port 1:
Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.466 |
| eddLoopProtectionPort1TimeOfLastLoopRemoteB EDD Series card Loop Protection Status for Port 1:
Time of Last Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.467 |
| eddLoopProtectionPort2ActionStsRemoteB EDD Series card Loop Protection Status for Port 2:
Action | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.468 |
| eddLoopProtectionPort2TransStsRemoteB EDD Series card Loop Protection Status for Port 2:
Transmit | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.469 |
| eddPort1PacketsTxRemoteB EDD Series card port1 traffic overview::
Packets Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.47 |
| eddLoopProtectionPort2LoopsStsRemoteB EDD Series card Loop Protection Status for Port 2:
Loops | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.470 |
| eddLoopProtectionPort2StatusRemoteB EDD Series card Loop Protection Status for Port 2:
Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.471 |
| eddLoopProtectionPort2LoopStsRemoteB EDD Series card Loop Protection Status for Port 2:
Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.472 |
| eddLoopProtectionPort2TimeOfLastLoopRemoteB EDD Series card Loop Protection Status for Port 2:
Time of Last Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.473 |
| eddLoopProtectionPort3ActionStsRemoteB EDD Series card Loop Protection Status for Port 3:
Action | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.474 |
| eddLoopProtectionPort3TransStsRemoteB EDD Series card Loop Protection Status for Port 3:
Transmit | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.475 |
| eddLoopProtectionPort3LoopsStsRemoteB EDD Series card Loop Protection Status for Port 3:
Loops | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.476 |
| eddLoopProtectionPort3StatusRemoteB EDD Series card Loop Protection Status for Port 3:
Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.477 |
| eddLoopProtectionPort3LoopStsRemoteB EDD Series card Loop Protection Status for Port 3:
Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.478 |
| eddLoopProtectionPort3TimeOfLastLoopRemoteB EDD Series card Loop Protection Status for Port 3:
Time of Last Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.479 |
| eddPort1BytesRxRemoteB EDD Series card port1 traffic overview::
Bytes Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.48 |
| eddLoopProtectionPort4ActionStsRemoteB EDD Series card Loop Protection Status for Port 4:
Action | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.480 |
| eddLoopProtectionPort4TransStsRemoteB EDD Series card Loop Protection Status for Port 4:
Transmit | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.481 |
| eddLoopProtectionPort4LoopsStsRemoteB EDD Series card Loop Protection Status for Port 4:
Loops | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.482 |
| eddLoopProtectionPort4StatusRemoteB EDD Series card Loop Protection Status for Port 4:
Status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.483 |
| eddLoopProtectionPort4LoopStsRemoteB EDD Series card Loop Protection Status for Port 4:
Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.484 |
| eddLoopProtectionPort4TimeOfLastLoopRemoteB EDD Series card Loop Protection Status for Port 4:
Time of Last Loop | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.485 |
| eddSTPProtocolVersionRemoteB EDD Series card STP Bridge Configuration:
Basic Settings - Protocol Version
0: STP
1: RSTP
2: MSTP | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.486 |
| eddSTPBridgePriorityRemoteB EDD Series card STP Bridge Configuration:
Basic Settings - Bridge Priority
0: 0 1: 4096 2: 8192 3: 12288
4: 16384 5: 20480 6: 24576 7: 28672
8: 32768 9: 36864 10:40960 11:… | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.487 |
| eddSTPForwardDelayRemoteB EDD Series card STP Bridge Configuration:
Basic Settings - Forward Delay | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.488 |
| eddSTPMaxAgeRemoteB EDD Series card STP Bridge Configuration:
Basic Settings - Max Age | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.489 |
| eddPort1BytesTxRemoteB EDD Series card port1 traffic overview::
Bytes Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.49 |
| eddSTPMaximumHopCountRemoteB EDD Series card STP Bridge Configuration:
Basic Settings - Maximum Hop Count | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.490 |
| eddSTPTransmitHoldCountRemoteB EDD Series card STP Bridge Configuration:
Basic Settings - Transmit Hold Count | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.491 |
| eddSTPEdgePortBPDUFilteringRemoteB EDD Series card STP Bridge Configuration:
Advanced Settings - Edge Port BPDU Filtering
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.492 |
| eddSTPEdgePortBPDUGuardRemoteB EDD Series card STP Bridge Configuration:
Advanced Settings - Edge Port BPDU Guard
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.493 |
| eddSTPPortErrorRecoveryTimeoutRemoteB EDD Series card STP Bridge Configuration:
Advanced Settings - Port Error Recovery Timeout
0: Off
1: On | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.494 |
| eddMSTIConfigurationNameRemoteB EDD Series card MSTI Configuration:
Configuration Identification - Configuration Name | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.495 |
| eddMSTIConfigurationRevisionRemoteB EDD Series card MSTI Configuration:
Configuration Identification - Configuration Revision | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.496 |
| eddMSTI1VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 1 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.497 |
| eddMSTI2VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 2 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.498 |
| eddMSTI3VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 3 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.499 |
| eddCardCPLDVerRemoteB EDD Series card CPLD version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.5 |
| eddPort1ErrorsRxRemoteB EDD Series card port1 traffic overview::
Errors Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.50 |
| eddMSTI4VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 4 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.500 |
| eddMSTI5VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 5 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.501 |
| eddMSTI6VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 6 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.502 |
| eddMSTI7VLANsMappingRemoteB EDD Series card MSTI Configuration:
MSTI Mapping - MSTI 7 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.503 |
| eddCISTAggregatedSTPEnabledRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - STP Enabled | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.504 |
| eddCISTAggregatedPathCostRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting … | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.505 |
| eddCISTAggregatedPriorityRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.506 |
| eddCISTAggregatedAdminEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - STP Enabled
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.507 |
| eddCISTAggregatedAutoEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - Auto Edge
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.508 |
| eddCISTAggregatedRestrictedRoleRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - Restricted Role
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.509 |
| eddPort1ErrorsTxRemoteB EDD Series card port1 traffic overview::
Errors Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.51 |
| eddCISTAggregatedRestrictedTCNRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - Restricted TCN
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.510 |
| eddCISTAggregatedBPDUGuardRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - BPDU Guard
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.511 |
| eddCISTAggregatedPointToPointRemoteB EDD Series card STP CIST Port Configuration:
CIST Aggregated Port Configuration - Point-to-point
0: Forced True
1: Forced False
2: Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.512 |
| eddCISTPort1STPEnabledRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - STP Enabled | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.513 |
| eddCISTPort1PathCostRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.514 |
| eddCISTPort1PriorityRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.515 |
| eddCISTPort1AdminEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - STP Enabled
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.516 |
| eddCISTPort1AutoEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - Auto Edge
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.517 |
| eddCISTPort1RestrictedRoleRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - Restricted Role
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.518 |
| eddCISTPort1RestrictedTCNRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - Restricted TCN
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.519 |
| eddPort1DropsRxRemoteB EDD Series card port1 traffic overview::
Drops Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.52 |
| eddCISTPort1BPDUGuardRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - BPDU Guard
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.520 |
| eddCISTPort1PointToPointRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port1 Configuration - Point-to-point
0: Forced True
1: Forced False
2: Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.521 |
| eddCISTPort2STPEnabledRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - STP Enabled | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.522 |
| eddCISTPort2PathCostRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.523 |
| eddCISTPort2PriorityRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.524 |
| eddCISTPort2AdminEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - STP Enabled
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.525 |
| eddCISTPort2AutoEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - Auto Edge
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.526 |
| eddCISTPort2RestrictedRoleRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - Restricted Role
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.527 |
| eddCISTPort2RestrictedTCNRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - Restricted TCN
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.528 |
| eddCISTPort2BPDUGuardRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - BPDU Guard
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.529 |
| eddPort1DropsTxRemoteB EDD Series card port1 traffic overview::
Drops Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.53 |
| eddCISTPort2PointToPointRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port2 Configuration - Point-to-point
0: Forced True
1: Forced False
2: Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.530 |
| eddCISTPort3STPEnabledRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - STP Enabled | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.531 |
| eddCISTPort3PathCostRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.532 |
| eddCISTPort3PriorityRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.533 |
| eddCISTPort3AdminEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - STP Enabled
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.534 |
| eddCISTPort3AutoEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - Auto Edge
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.535 |
| eddCISTPort3RestrictedRoleRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - Restricted Role
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.536 |
| eddCISTPort3RestrictedTCNRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - Restricted TCN
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.537 |
| eddCISTPort3BPDUGuardRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - BPDU Guard
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.538 |
| eddCISTPort3PointToPointRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port3 Configuration - Point-to-point
0: Forced True
1: Forced False
2: Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.539 |
| eddPort1FilteredRxRemoteB EDD Series card port1 traffic overview::
Filtered Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.54 |
| eddCISTPort4STPEnabledRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - STP Enabled | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.540 |
| eddCISTPort4PathCostRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.541 |
| eddCISTPort4PriorityRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.542 |
| eddCISTPort4AdminEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - STP Enabled
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.543 |
| eddCISTPort4AutoEdgeRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - Auto Edge
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.544 |
| eddCISTPort4RestrictedRoleRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - Restricted Role
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.545 |
| eddCISTPort4RestrictedTCNRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - Restricted TCN
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.546 |
| eddCISTPort4BPDUGuardRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - BPDU Guard
0: Non-edge
1: Edge | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.547 |
| eddCISTPort4PointToPointRemoteB EDD Series card STP CIST Port Configuration:
CIST Normal Port4 Configuration - Point-to-point
0: Forced True
1: Forced False
2: Auto | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.548 |
| eddMSTI1AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.549 |
| eddPort2PacketsRxRemoteB EDD Series card port2 traffic overview::
Packets Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.55 |
| eddMSTI1AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.550 |
| eddMSTI1Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.551 |
| eddMSTI1Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.552 |
| eddMSTI1Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.553 |
| eddMSTI1Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.554 |
| eddMSTI1Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.555 |
| eddMSTI1Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.556 |
| eddMSTI1Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.557 |
| eddMSTI1Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.558 |
| eddMSTI2AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.559 |
| eddPort2PacketsTxRemoteB EDD Series card port2 traffic overview::
Packets Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.56 |
| eddMSTI2AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.560 |
| eddMSTI2Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.561 |
| eddMSTI2Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.562 |
| eddMSTI2Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.563 |
| eddMSTI2Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.564 |
| eddMSTI2Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.565 |
| eddMSTI2Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.566 |
| eddMSTI2Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.567 |
| eddMSTI2Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI2 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.568 |
| eddMSTI3AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.569 |
| eddPort2BytesRxRemoteB EDD Series card port2 traffic overview::
Bytes Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.57 |
| eddMSTI3AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.570 |
| eddMSTI3Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.571 |
| eddMSTI3Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.572 |
| eddMSTI3Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.573 |
| eddMSTI3Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.574 |
| eddMSTI3Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.575 |
| eddMSTI3Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.576 |
| eddMSTI3Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.577 |
| eddMSTI3Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI3 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.578 |
| eddMSTI4AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.579 |
| eddPort2BytesTxRemoteB EDD Series card port2 traffic overview::
Bytes Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.58 |
| eddMSTI4AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.580 |
| eddMSTI4Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.581 |
| eddMSTI4Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.582 |
| eddMSTI4Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.583 |
| eddMSTI4Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.584 |
| eddMSTI4Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.585 |
| eddMSTI4Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.586 |
| eddMSTI4Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.587 |
| eddMSTI4Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI4 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.588 |
| eddMSTI5AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.589 |
| eddPort2ErrorsRxRemoteB EDD Series card port2 traffic overview::
Errors Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.59 |
| eddMSTI5AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.590 |
| eddMSTI5Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.591 |
| eddMSTI5Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.592 |
| eddMSTI5Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.593 |
| eddMSTI5Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.594 |
| eddMSTI5Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.595 |
| eddMSTI5Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.596 |
| eddMSTI5Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.597 |
| eddMSTI5Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI5 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.598 |
| eddMSTI6AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.599 |
| eddCardFPGAVerRemoteB EDD Series card FPGA version x.xxx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.6 |
| eddPort2ErrorsTxRemoteB EDD Series card port2 traffic overview::
Errors Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.60 |
| eddMSTI6AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.600 |
| eddMSTI6Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.601 |
| eddMSTI6Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port1 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.602 |
| eddMSTI6Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.603 |
| eddMSTI6Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.604 |
| eddMSTI6Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.605 |
| eddMSTI6Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.606 |
| eddMSTI6Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.607 |
| eddMSTI6Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI6 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.608 |
| eddMSTI7AggregatedPathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Aggregated Ports Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.609 |
| eddPort2DropsRxRemoteB EDD Series card port2 traffic overview::
Drops Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.61 |
| eddMSTI7AggregatedPriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Aggregated Ports Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.610 |
| eddMSTI7Port1PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port1 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.611 |
| eddMSTI7Port1PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI1 Normal Port7 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.612 |
| eddMSTI7Port2PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Normal Port2 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.613 |
| eddMSTI7Port2PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Normal Port2 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.614 |
| eddMSTI7Port3PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Normal Port3 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.615 |
| eddMSTI7Port3PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Normal Port3 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.616 |
| eddMSTI7Port4PathCostRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Normal Port4 Configuration - Path Cost
Valid values are in the range 0 to 200000000.
Setting 0 means Auto path cost.
Setting 1 ~ 200… | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.617 |
| eddMSTI7Port4PriorityRemoteB EDD Series card MSTI Port Configuration:
MSTI7 Normal Port4 Configuration - Priority | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.618 |
| eddCISTBridgeIDRemoteB EDD Series card STP Bridges status:
CIST - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.619 |
| eddPort2DropsTxRemoteB EDD Series card port2 traffic overview::
Drops Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.62 |
| eddCISTRootIDRemoteB EDD Series card STP Bridges status:
CIST - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.620 |
| eddCISTRootPortRemoteB EDD Series card STP Bridges status:
CIST - Root Port | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.621 |
| eddCISTRootCostRemoteB EDD Series card STP Bridges status:
CIST - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.622 |
| eddCISTTopologyFlagRemoteB EDD Series card STP Bridges status:
CIST - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.623 |
| eddCISTTopologyChangeLastRemoteB EDD Series card STP Bridges status:
CIST - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.624 |
| eddMSTI1BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI1 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.625 |
| eddMSTI1RootIDRemoteB EDD Series card STP Bridges status:
MSTI1 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.626 |
| eddMSTI1RootPortRemoteB EDD Series card STP Bridges status:
MSTI1 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.627 |
| eddMSTI1RootCostRemoteB EDD Series card STP Bridges status:
MSTI1 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.628 |
| eddMSTI1TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI1 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.629 |
| eddPort2FilteredRxRemoteB EDD Series card port2 traffic overview::
Filtered Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.63 |
| eddMSTI1TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI1 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.630 |
| eddMSTI2BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI2 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.631 |
| eddMSTI2RootIDRemoteB EDD Series card STP Bridges status:
MSTI2 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.632 |
| eddMSTI2RootPortRemoteB EDD Series card STP Bridges status:
MSTI2 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.633 |
| eddMSTI2RootCostRemoteB EDD Series card STP Bridges status:
MSTI2 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.634 |
| eddMSTI2TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI2 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.635 |
| eddMSTI2TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI2 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.636 |
| eddMSTI3BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI3 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.637 |
| eddMSTI3RootIDRemoteB EDD Series card STP Bridges status:
MSTI3 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.638 |
| eddMSTI3RootPortRemoteB EDD Series card STP Bridges status:
MSTI3 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.639 |
| eddPort3PacketsRxRemoteB EDD Series card port3 traffic overview::
Packets Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.64 |
| eddMSTI3RootCostRemoteB EDD Series card STP Bridges status:
MSTI3 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.640 |
| eddMSTI3TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI3 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.641 |
| eddMSTI3TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI3 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.642 |
| eddMSTI4BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI4 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.643 |
| eddMSTI4RootIDRemoteB EDD Series card STP Bridges status:
MSTI4 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.644 |
| eddMSTI4RootPortRemoteB EDD Series card STP Bridges status:
MSTI4 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.645 |
| eddMSTI4RootCostRemoteB EDD Series card STP Bridges status:
MSTI4 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.646 |
| eddMSTI4TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI4 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.647 |
| eddMSTI4TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI4 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.648 |
| eddMSTI5BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI5 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.649 |
| eddPort3PacketsTxRemoteB EDD Series card port3 traffic overview::
Packets Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.65 |
| eddMSTI5RootIDRemoteB EDD Series card STP Bridges status:
MSTI5 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.650 |
| eddMSTI5RootPortRemoteB EDD Series card STP Bridges status:
MSTI5 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.651 |
| eddMSTI5RootCostRemoteB EDD Series card STP Bridges status:
MSTI5 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.652 |
| eddMSTI5TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI5 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.653 |
| eddMSTI5TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI5 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.654 |
| eddMSTI6BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI6 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.655 |
| eddMSTI6RootIDRemoteB EDD Series card STP Bridges status:
MSTI6 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.656 |
| eddMSTI6RootPortRemoteB EDD Series card STP Bridges status:
MSTI6 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.657 |
| eddMSTI6RootCostRemoteB EDD Series card STP Bridges status:
MSTI6 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.658 |
| eddMSTI6TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI6 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.659 |
| eddPort3BytesRxRemoteB EDD Series card port3 traffic overview::
Bytes Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.66 |
| eddMSTI6TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI6 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.660 |
| eddMSTI7BridgeIDRemoteB EDD Series card STP Bridges status:
MSTI7 - Bridge ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.661 |
| eddMSTI7RootIDRemoteB EDD Series card STP Bridges status:
MSTI7 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.662 |
| eddMSTI7RootPortRemoteB EDD Series card STP Bridges status:
MSTI7 - Root ID | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.663 |
| eddMSTI7RootCostRemoteB EDD Series card STP Bridges status:
MSTI7 - Root Cost | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.664 |
| eddMSTI7TopologyFlagRemoteB EDD Series card STP Bridges status:
MSTI7 - Topology Flag | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.665 |
| eddMSTI7TopologyChangeLastRemoteB EDD Series card STP Bridges status:
MSTI7 - Topology Change Last | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.666 |
| eddSTPPortStatusInst1PortRemoteB EDD Series card STP Port status:
Instance1 - Port | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.667 |
| eddSTPPortStatusInst1CISTRoleRemoteB EDD Series card STP Port status:
Instance1 - CIST Role | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.668 |
| eddSTPPortStatusInst1CISTStateRemoteB EDD Series card STP Port status:
Instance1 - CIST State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.669 |
| eddPort3BytesTxRemoteB EDD Series card port3 traffic overview::
Bytes Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.67 |
| eddSTPPortStatusInst1UptimeRemoteB EDD Series card STP Port status:
Instance1 -Uptime | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.670 |
| eddSTPPortStatusInst2PortRemoteB EDD Series card STP Port status:
Instance2 - Port | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.671 |
| eddSTPPortStatusInst2CISTRoleRemoteB EDD Series card STP Port status:
Instance2 - CIST Role | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.672 |
| eddSTPPortStatusInst2CISTStateRemoteB EDD Series card STP Port status:
Instance2 - CIST State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.673 |
| eddSTPPortStatusInst2UptimeRemoteB EDD Series card STP Port status:
Instance2 -Uptime | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.674 |
| eddSTPPortStatusInst3PortRemoteB EDD Series card STP Port status:
Instance3 - Port | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.675 |
| eddSTPPortStatusInst3CISTRoleRemoteB EDD Series card STP Port status:
Instance3 - CIST Role | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.676 |
| eddSTPPortStatusInst3CISTStateRemoteB EDD Series card STP Port status:
Instance3 - CIST State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.677 |
| eddSTPPortStatusInst3UptimeRemoteB EDD Series card STP Port status:
Instance3 -Uptime | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.678 |
| eddSTPPortStatusInst4PortRemoteB EDD Series card STP Port status:
Instance4 - Port | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.679 |
| eddPort3ErrorsRxRemoteB EDD Series card port3 traffic overview::
Errors Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.68 |
| eddSTPPortStatusInst4CISTRoleRemoteB EDD Series card STP Port status:
Instance4 - CIST Role | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.680 |
| eddSTPPortStatusInst4CISTStateRemoteB EDD Series card STP Port status:
Instance4 - CIST State | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.681 |
| eddSTPPortStatusInst4UptimeRemoteB EDD Series card STP Port status:
Instance4 -Uptime | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.682 |
| eddSTPStatisticsPort1TxMSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Transmitted MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.683 |
| eddSTPStatisticsPort1TxRSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.684 |
| eddSTPStatisticsPort1TxSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.685 |
| eddSTPStatisticsPort1TxTCNRemoteB EDD Series card STP Port Statistics:
Port1 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.686 |
| eddSTPStatisticsPort1RxMSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Received MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.687 |
| eddSTPStatisticsPort1RxRSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.688 |
| eddSTPStatisticsPort1RxSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.689 |
| eddPort3ErrorsTxRemoteB EDD Series card port3 traffic overview::
Errors Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.69 |
| eddSTPStatisticsPort1RxTCNRemoteB EDD Series card STP Port Statistics:
Port1 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.690 |
| eddSTPStatisticsPort1DiscardUnknowRemoteB EDD Series card STP Port Statistics:
Port1 -Discarded Unknown | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.691 |
| eddSTPStatisticsPort1DiscardIllegalRemoteB EDD Series card STP Port Statistics:
Port1 -Discarded Illegal | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.692 |
| eddSTPStatisticsPort2TxMSTPRemoteB EDD Series card STP Port Statistics:
Port2 -Transmitted MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.693 |
| eddSTPStatisticsPort2TxRSTPRemoteB EDD Series card STP Port Statistics:
Port2 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.694 |
| eddSTPStatisticsPort2TxSTPRemoteB EDD Series card STP Port Statistics:
Port2 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.695 |
| eddSTPStatisticsPort2TxTCNRemoteB EDD Series card STP Port Statistics:
Port2 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.696 |
| eddSTPStatisticsPort2RxMSTPRemoteB EDD Series card STP Port Statistics:
Port2 -Received MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.697 |
| eddSTPStatisticsPort2RxRSTPRemoteB EDD Series card STP Port Statistics:
Port1 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.698 |
| eddSTPStatisticsPort2RxSTPRemoteB EDD Series card STP Port Statistics:
Port2 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.699 |
| eddModelRemoteB Card Type:
0:MX210
1:MSW202 | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.7 |
| eddPort3DropsRxRemoteB EDD Series card port3 traffic overview::
Drops Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.70 |
| eddSTPStatisticsPort2RxTCNRemoteB EDD Series card STP Port Statistics:
Port2 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.700 |
| eddSTPStatisticsPort2DiscardUnknowRemoteB EDD Series card STP Port Statistics:
Port2 -Discarded Unknown | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.701 |
| eddSTPStatisticsPort2DiscardIllegalRemoteB EDD Series card STP Port Statistics:
Port2 -Discarded Illegal | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.702 |
| eddSTPStatisticsPort3TxMSTPRemoteB EDD Series card STP Port Statistics:
Port3 -Transmitted MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.703 |
| eddSTPStatisticsPort3TxRSTPRemoteB EDD Series card STP Port Statistics:
Port3 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.704 |
| eddSTPStatisticsPort3TxSTPRemoteB EDD Series card STP Port Statistics:
Port3 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.705 |
| eddSTPStatisticsPort3TxTCNRemoteB EDD Series card STP Port Statistics:
Port3 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.706 |
| eddSTPStatisticsPort3RxMSTPRemoteB EDD Series card STP Port Statistics:
Port3 -Received MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.707 |
| eddSTPStatisticsPort3RxRSTPRemoteB EDD Series card STP Port Statistics:
Port3 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.708 |
| eddSTPStatisticsPort3RxSTPRemoteB EDD Series card STP Port Statistics:
Port3 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.709 |
| eddPort3DropsTxRemoteB EDD Series card port3 traffic overview::
Drops Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.71 |
| eddSTPStatisticsPort3RxTCNRemoteB EDD Series card STP Port Statistics:
Port3 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.710 |
| eddSTPStatisticsPort3DiscardUnknowRemoteB EDD Series card STP Port Statistics:
Port3 -Discarded Unknown | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.711 |
| eddSTPStatisticsPort3DiscardIllegalRemoteB EDD Series card STP Port Statistics:
Port3 -Discarded Illegal | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.712 |
| eddSTPStatisticsPort4TxMSTPRemoteB EDD Series card STP Port Statistics:
Port4 -Transmitted MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.713 |
| eddSTPStatisticsPort4TxRSTPRemoteB EDD Series card STP Port Statistics:
Port4 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.714 |
| eddSTPStatisticsPort4TxSTPRemoteB EDD Series card STP Port Statistics:
Port4 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.715 |
| eddSTPStatisticsPort4TxTCNRemoteB EDD Series card STP Port Statistics:
Port4 -Transmitted RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.716 |
| eddSTPStatisticsPort4RxMSTPRemoteB EDD Series card STP Port Statistics:
Port4 -Received MSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.717 |
| eddSTPStatisticsPort4RxRSTPRemoteB EDD Series card STP Port Statistics:
Port4 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.718 |
| eddSTPStatisticsPort4RxSTPRemoteB EDD Series card STP Port Statistics:
Port4 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.719 |
| eddPort3FilteredRxRemoteB EDD Series card port3 traffic overview::
Filtered Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.72 |
| eddSTPStatisticsPort4RxTCNRemoteB EDD Series card STP Port Statistics:
Port4 -Received RSTP | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.720 |
| eddSTPStatisticsPort4DiscardUnknowRemoteB EDD Series card STP Port Statistics:
Port4 -Discarded Unknown | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.721 |
| eddSTPStatisticsPort4DiscardIllegalRemoteB EDD Series card STP Port Statistics:
Port4 -Discarded Illegal | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.722 |
| eddSTPStatisticsPortClearCounterRemoteB EDD Series card STP Port Statistics:
Clear Counters
0: OFff
1: Action | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.723 |
| eddAllowedAccessVLANsRemoteB EDD Series card Global VLAN Configuration:
Allowed Access VLANs
By default, only VLAN 1 is enabled.
More VLANs may be created by using a list syntax where the individual element… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.724 |
| eddVlanEthertypeRemoteB EDD Series card Global VLAN Configuration:
Ethertype for Custom S-ports
The format of 'Ethernet Type' is restricted to 0x600-0xFFFF | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.725 |
| eddPort1VlanModeRemoteB EDD Series card Port VLAN Configuration :
Port1 - Mode
0: Access
1: Trunk
2: Hybrid | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.726 |
| eddPort1VlanIDRemoteB EDD Series card Port VLAN Configuration :
Port1 - VLAN ID | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.727 |
| eddPort1VlanTypeRemoteB EDD Series card Port VLAN Configuration :
Port1 - VLAN Type
0: Unaware
1: C-port
2: S-port
3: S-custom-port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.728 |
| eddPort1VlanIngressFilteringRemoteB EDD Series card Port VLAN Configuration :
Port1 - Ingress Filtering
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.729 |
| eddPort4PacketsRxRemoteB EDD Series card port4 traffic overview::
Packets Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.73 |
| eddPort1VlanIngressAcceptanceRemoteB EDD Series card Port VLAN Configuration :
Port1 - Ingress Acceptance
0: Tagged and untagged
1: Tagged only
2: Untagged only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.730 |
| eddPort1VlanEgressTaggingRemoteB EDD Series card Port VLAN Configuration :
Port1 - Egress Tagging
0: Untag port vlan
1: Tag all
2: Untag all | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.731 |
| eddPort1AllowedVLANSRemoteB EDD Series card Global VLAN Configuration:
Port1 - Allowed VLANs
By default, only VLAN 1 is enabled.
More VLANs may be created by using a list syntax where the individual elemen… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.732 |
| eddPort1ForbiddenVLANSRemoteB EDD Series card Global VLAN Configuration:
Port1 - Forbidden VLANs
By default, the field is left blank, which means that the port may become a member of all possible VLANs. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.733 |
| eddPort2VlanModeRemoteB EDD Series card Port VLAN Configuration :
Port2 - Mode
0: Access
1: Trunk
2: Hybrid | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.734 |
| eddPort2VlanIDRemoteB EDD Series card Port VLAN Configuration :
Port2 - VLAN ID | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.735 |
| eddPort2VlanTypeRemoteB EDD Series card Port VLAN Configuration :
Port2 - VLAN Type
0: Unaware
1: C-port
2: S-port
3: S-custom-port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.736 |
| eddPort2VlanIngressFilteringRemoteB EDD Series card Port VLAN Configuration :
Port2 - Ingress Filtering
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.737 |
| eddPort2VlanIngressAcceptanceRemoteB EDD Series card Port VLAN Configuration :
Por2 - Ingress Acceptance
0: Tagged and untagged
1: Tagged only
2: Untagged only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.738 |
| eddPort2VlanEgressTaggingRemoteB EDD Series card Port VLAN Configuration :
Port2 - Egress Tagging
0: Untag port vlan
1: Tag all
2: Untag all | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.739 |
| eddPort4PacketsTxRemoteB EDD Series card port4 traffic overview::
Packets Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.74 |
| eddPort2AllowedVLANSRemoteB EDD Series card Global VLAN Configuration:
Port2 - Allowed VLANs
By default, only VLAN 1 is enabled.
More VLANs may be created by using a list syntax where the individual elemen… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.740 |
| eddPort2ForbiddenVLANSRemoteB EDD Series card Global VLAN Configuration:
Port2 - Forbidden VLANs
By default, the field is left blank, which means that the port may become a member of all possible VLANs. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.741 |
| eddPort3VlanModeRemoteB EDD Series card Port VLAN Configuration :
Port3 - Mode
0: Access
1: Trunk
2: Hybrid | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.742 |
| eddPort3VlanIDRemoteB EDD Series card Port VLAN Configuration :
Port3 - VLAN ID | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.743 |
| eddPort3VlanTypeRemoteB EDD Series card Port VLAN Configuration :
Port3 - VLAN Type
0: Unaware
1: C-port
2: S-port
3: S-custom-port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.744 |
| eddPort3VlanIngressFilteringRemoteB EDD Series card Port VLAN Configuration :
Port3 - Ingress Filtering
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.745 |
| eddPort3VlanIngressAcceptanceRemoteB EDD Series card Port VLAN Configuration :
Port3 - Ingress Acceptance
0: Tagged and untagged
1: Tagged only
2: Untagged only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.746 |
| eddPort3VlanEgressTaggingRemoteB EDD Series card Port VLAN Configuration :
Port3 - Egress Tagging
0: Untag port vlan
1: Tag all
2: Untag all | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.747 |
| eddPort3AllowedVLANSRemoteB EDD Series card Global VLAN Configuration:
Port3 - Allowed VLANs
By default, only VLAN 1 is enabled.
More VLANs may be created by using a list syntax where the individual elemen… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.748 |
| eddPort3ForbiddenVLANSRemoteB EDD Series card Global VLAN Configuration:
Port3 - Forbidden VLANs
By default, the field is left blank, which means that the port may become a member of all possible VLANs. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.749 |
| eddPort4BytesRxRemoteB EDD Series card port4 traffic overview::
Bytes Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.75 |
| eddPort4VlanModeRemoteB EDD Series card Port VLAN Configuration :
Port4 - Mode
0: Access
1: Trunk
2: Hybrid | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.750 |
| eddPort4VlanIDRemoteB EDD Series card Port VLAN Configuration :
Port4 - VLAN ID | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.751 |
| eddPort4VlanTypeRemoteB EDD Series card Port VLAN Configuration :
Port4 - VLAN Type
0: Unaware
1: C-port
2: S-port
3: S-custom-port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.752 |
| eddPort4VlanIngressFilteringRemoteB EDD Series card Port VLAN Configuration :
Port4 - Ingress Filtering
0: Off
1: On | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.753 |
| eddPort4VlanIngressAcceptanceRemoteB EDD Series card Port VLAN Configuration :
Port4 - Ingress Acceptance
0: Tagged and untagged
1: Tagged only
2: Untagged only | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.754 |
| eddPort4VlanEgressTaggingRemoteB EDD Series card Port VLAN Configuration :
Port4 - Egress Tagging
0: Untag port vlan
1: Tag all
2: Untag all | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.755 |
| eddPort4AllowedVLANSRemoteB EDD Series card Global VLAN Configuration:
Port4 - Allowed VLANs
By default, only VLAN 1 is enabled.
More VLANs may be created by using a list syntax where the individual elemen… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.756 |
| eddPort4ForbiddenVLANSRemoteB EDD Series card Global VLAN Configuration:
Port4 - Forbidden VLANs
By default, the field is left blank, which means that the port may become a member of all possible VLANs. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.757 |
| eddDNSServerTypeRemoteB EDD Series card IP Configuration:
This setting controls the DNS name resolution done by the switch. The following modes are supported:
1:From any DHCP interfaces
The first DNS … | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.758 |
| eddDNSServerSettingRemoteB EDD Series card IP Configuration:
If iDNSServerType setting '3:Configured',this value must setting IP address format as below:
Dotted Decimal Notation refers to a method of writin… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.759 |
| eddPort4BytesTxRemoteB EDD Series card port4 traffic overview::
Bytes Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.76 |
| eddDNSproxyRemoteB EDD Series card IP Configuration:
When DNS proxy is enabled, system will relay DNS requests to the currently configured DNS server,
and reply as a DNS resolver to the client devi… | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.760 |
| eddAddIPV4InterfaceRemoteB EDD Series card IP Interfaces:
Add a new IP VLAN Interface:
Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>]
Interface : 1~4 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.761 |
| eddDeleteInterfaceRemoteB EDD Series card IP Interfaces:
Delete a IPv4/v6 VLAN Interface:
Syntax: [<Interface>]
Interface: 1~4 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.762 |
| eddIPInterface1DHCPRemoteB EDD Series card IP Interfaces:
DHCP | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.764 |
| eddIPInterface1FallbackRemoteB EDD Series card IP Interfaces:
Fallback | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.765 |
| eddIPInterface1IPV4AddressRemoteB EDD Series card IP Interfaces:
IPV4 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.766 |
| eddIPInterface1IPV4MASKLenRemoteB EDD Series card IP Interfaces:
IPV4 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.767 |
| eddIPInterface2VLANRemoteB EDD Series card IP Interfaces:
The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface.
This field is only available for input … | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.768 |
| eddIPInterface2DHCPRemoteB EDD Series card IP Interfaces:
DHCP | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.769 |
| eddPort4ErrorsRxRemoteB EDD Series card port4 traffic overview::
Errors Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.77 |
| eddIPInterface2FallbackRemoteB EDD Series card IP Interfaces:
Fallback | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.770 |
| eddIPInterface2IPV4AddressRemoteB EDD Series card IP Interfaces:
IPV4 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.771 |
| eddIPInterface2IPV4MASKLenRemoteB EDD Series card IP Interfaces:
IPV4 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.772 |
| eddIPInterface3VLANRemoteB EDD Series card IP Interfaces:
The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface.
This field is only available for input … | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.773 |
| eddIPInterface3DHCPRemoteB EDD Series card IP Interfaces:
DHCP | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.774 |
| eddIPInterface3FallbackRemoteB EDD Series card IP Interfaces:
Fallback | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.775 |
| eddIPInterface3IPV4AddressRemoteB EDD Series card IP Interfaces:
IPV4 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.776 |
| eddIPInterface3IPV4MASKLenRemoteB EDD Series card IP Interfaces:
IPV4 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.777 |
| eddIPInterface4VLANRemoteB EDD Series card IP Interfaces:
The VLAN associated with the IP interface. Only ports in this VLAN will be able to access the IP interface.
This field is only available for input … | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.778 |
| eddIPInterface4DHCPRemoteB EDD Series card IP Interfaces:
DHCP | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.779 |
| eddPort4ErrorsTxRemoteB EDD Series card port4 traffic overview::
Errors Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.78 |
| eddIPInterface4FallbackRemoteB EDD Series card IP Interfaces:
Fallback | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.780 |
| eddIPInterface4IPV4AddressRemoteB EDD Series card IP Interfaces:
IPV4 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.781 |
| eddIPInterface4IPV4MASKLenRemoteB EDD Series card IP Interfaces:
IPV4 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.782 |
| eddAddIPV6InterfaceRemoteB EDD Series card IP Interfaces:
Add a new IPv6 VLAN Interface:
Syntax: [<Interface>] [<vlan_list>] [<IPV4_Addr>] [<IPV4_MASK>]
Interface : 1~4 | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.783 |
| eddIPInterface1IPV6AddressRemoteB EDD Series card IP Interfaces:
IPV6 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.784 |
| eddIPInterface1IPV6MASKLenRemoteB EDD Series card IP Interfaces:
IPV6 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.785 |
| eddIPInterface2IPV6AddressRemoteB EDD Series card IP Interfaces:
IPV6 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.786 |
| eddIPInterface2IPV6MASKLenRemoteB EDD Series card IP Interfaces:
IPV6 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.787 |
| eddIPInterface3IPV6AddressRemoteB EDD Series card IP Interfaces:
IPV6 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.788 |
| eddIPInterface3IPV6MASKLenRemoteB EDD Series card IP Interfaces:
IPV6 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.789 |
| eddPort4DropsRxRemoteB EDD Series card port4 traffic overview::
Drops Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.79 |
| eddIPInterface4IPV6AddressRemoteB EDD Series card IP Interfaces:
IPV6 Address | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.790 |
| eddIPInterface4IPV6MASKLenRemoteB EDD Series card IP Interfaces:
IPV6 MASK Length | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.791 |
| eddPort1ALSRemoteB EDD Series card Port1 auto laser shutdown:
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.792 |
| eddPort2ALSRemoteB EDD Series card Port2 auto laser shutdown:
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.793 |
| eddPort3ALSRemoteB EDD Series card Port3 auto laser shutdown (MX210 only):
0: Disable
1: Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.794 |
| eddPort1LLFLogicRemoteB EDD Series card Port1 link loss forwarding - Logic
0: AND
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.795 |
| eddPort1LLFLogicPort2RemoteB EDD Series card Port1 link loss forwarding - Link/Rx Loss Port2
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.796 |
| eddPort1LLFLogicPort3RemoteB EDD Series card Port1 link loss forwarding - Link/Rx Loss Port3
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.797 |
| eddPort1LLFLogicPort4RemoteB EDD Series card Port1 link loss forwarding - Link/Rx Loss Port4
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.798 |
| eddPort2LLFLogicRemoteB EDD Series card Port2 link loss forwarding - Logic
0: AND
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.799 |
| eddPort1LinkstsRemoteB EDD Series card Port1 link status:
0:Link down
1:Link up | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.8 |
| eddPort4DropsTxRemoteB EDD Series card port4 traffic overview::
Drops Tx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.80 |
| eddPort2LLFLogicPort1RemoteB EDD Series card Port2 link loss forwarding - Link/Rx Loss Port1
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.800 |
| eddPort2LLFLogicPort3RemoteB EDD Series card Port2 link loss forwarding - Link/Rx Loss Port3
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.801 |
| eddPort2LLFLogicPort4RemoteB EDD Series card Port2 link loss forwarding - Link/Rx Loss Port4
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.802 |
| eddPort3LLFLogicRemoteB EDD Series card Port1 link loss forwarding - Logic
0: AND
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.803 |
| eddPort3LLFLogicPort1RemoteB EDD Series card Port3 link loss forwarding - Link/Rx Loss Port1
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.804 |
| eddPort3LLFLogicPort2RemoteB EDD Series card Port3 link loss forwarding - Link/Rx Loss Port2
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.805 |
| eddPort3LLFLogicPort4RemoteB EDD Series card Port3 link loss forwarding - Link/Rx Loss Port4
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.806 |
| eddPort4LLFLogicRemoteB EDD Series card Port4 link loss forwarding - Logic
0: AND
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.807 |
| eddPort4LLFLogicPort1RemoteB EDD Series card Port4 link loss forwarding - Link/Rx Loss Port1
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.808 |
| eddPort4LLFLogicPort2RemoteB EDD Series card Port4 link loss forwarding - Link/Rx Loss Port2
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.809 |
| eddPort4FilteredRxRemoteB EDD Series card port4 traffic overview::
Filtered Rx | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.81 |
| eddPort4LLFLogicPort3RemoteB EDD Series card Port4 link loss forwarding - Link/Rx Loss Port3
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.810 |
| eddQOSPort1IngressRemoteB EDD Series card QOS Port1 Ingress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.811 |
| eddQOSPort1IngressRateRemoteB EDD Series card QOS Port1 Ingress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.812 |
| eddQOSPort1IngressRateUnitRemoteB EDD Series card QOS Port1 Ingress Rate Unit
0: Kbps
1: Mbps
2: fps
3: kfps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.813 |
| eddQOSPort1IngressFlowControlRemoteB EDD Series card QOS Port1 Ingress Flow Control
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.814 |
| eddQOSPort2IngressRemoteB EDD Series card QOS Port2 Ingress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.815 |
| eddQOSPort2IngressRateRemoteB EDD Series card QOS Port2 Ingress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.816 |
| eddQOSPort2IngressRateUnitRemoteB EDD Series card QOS Port2 Ingress Rate Unit
0: Kbps
1: Mbps
2: fps
3: kfps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.817 |
| eddQOSPort2IngressFlowControlRemoteB EDD Series card QOS Port2 Ingress Flow Control
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.818 |
| eddQOSPort3IngressRemoteB EDD Series card QOS Port3 Ingress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.819 |
| edduRingInstanceAddRemoteB EDD Series card
Add a new uRing Instance.
Syntax: <Instance ID> <ring|sub|chain> <port east> <port west>
Instance ID must be either 1 or 2
port east , the value is the switch… | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.82 |
| eddQOSPort3IngressRateRemoteB EDD Series card QOS Port3 Ingress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.820 |
| eddQOSPort3IngressRateUnitRemoteB EDD Series card QOS Port3 Ingress Rate Unit
0: Kbps
1: Mbps
2: fps
3: kfps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.821 |
| eddQOSPort3IngressFlowControlRemoteB EDD Series card QOS Port3 Ingress Flow Control
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.822 |
| eddQOSPort4IngressRemoteB EDD Series card QOS Port4 Ingress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.823 |
| eddQOSPort4IngressRateRemoteB EDD Series card QOS Port4 Ingress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.824 |
| eddQOSPort4IngressRateUnitRemoteB EDD Series card QOS Port4 Ingress Rate Unit
0: Kbps
1: Mbps
2: fps
3: kfps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.825 |
| eddQOSPort4IngressFlowControlRemoteB EDD Series card QOS Port4 Ingress Flow Control
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.826 |
| eddQOSPort1EgressRemoteB EDD Series card QOS Port1 Egress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.827 |
| eddQOSPort1EgressRateRemoteB EDD Series card QOS Port1 Egress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.828 |
| eddQOSPort1EgressRateUnitRemoteB EDD Series card QOS Port1 Egress Rate Unit
0: Kbps
1: Mbps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.829 |
| edduRingInstanceDeleteRemoteB EDD Series card
Delete a uRing Instance.
Syntax: <uRing Instance> | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.83 |
| eddQOSPort2EgressRemoteB EDD Series card QOS Port2 Egress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.830 |
| eddQOSPort2EgressRateRemoteB EDD Series card QOS Port2 Egress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.831 |
| eddQOSPort2EgressRateUnitRemoteB EDD Series card QOS Port2 Egress Rate Unit
0: Kbps
1: Mbps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.832 |
| eddQOSPort3EgressRemoteB EDD Series card QOS Port3 Egress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.833 |
| eddQOSPort3EgressRateRemoteB EDD Series card QOS Port3 Egress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.834 |
| eddQOSPort3EgressRateUnitRemoteB EDD Series card QOS Port3 Egress Rate Unit
0: Kbps
1: Mbps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.835 |
| eddQOSPort4EgressRemoteB EDD Series card QOS Port4 Egress Enabled
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.836 |
| eddQOSPort4EgressRateRemoteB EDD Series card QOS Port4 Egress Rate | column | Integer32 | .1.3.6.1.4.1.4756.20.442.20.1.837 |
| eddQOSPort4EgressRateUnitRemoteB EDD Series card QOS Port4 Egress Rate Unit
0: Kbps
1: Mbps | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.838 |
| eddQOSUnicastRemoteB EDD Series card QOS Storm Control Configuration- Unicast
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.839 |
| edduRingInst1IDRemoteB EDD Series card u-Ring instance1 ID | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.84 |
| eddQOSUnicastRateRemoteB EDD Series card QOS Storm Control Configuration- Unicast Rate
The rate unit is packets per second (pps).
0: 1
1: 2
2: 4
3: 8
4: 16
5: 32
6: 64
7: 128
8: 256
9: 512
10: 1K
11: 2… | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.840 |
| eddQOSMulticastRemoteB EDD Series card QOS Storm Control Configuration- Multicast
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.841 |
| eddQOSMulticastRateRemoteB EDD Series card QOS Storm Control Configuration- Multicast
The rate unit is packets per second (pps).
0: 1
1: 2
2: 4
3: 8
4: 16
5: 32
6: 64
7: 128
8: 256
9: 512
10: 1K
11: 2K
1… | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.842 |
| eddQOSBroadcastRemoteB EDD Series card QOS Storm Control Configuration- Broadcast
0: NO
1: YES | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.843 |
| eddQOSBroadcastRateRemoteB EDD Series card QOS Storm Control Configuration- Broadcast
The rate unit is packets per second (pps).
0: 1
1: 2
2: 4
3: 8
4: 16
5: 32
6: 64
7: 128
8: 256
9: 512
10: 1K
11: 2K
1… | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.844 |
| eddL2CPPort1DMAC0180C2000000RemoteB EDD Series card Port 1 L2CP Mode
0180C2000000
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.845 |
| eddL2CPPort1DMAC0180C2000001RemoteB EDD Series card Port 1 L2CP Mode
0180C2000001
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.846 |
| eddL2CPPort1DMAC0180C2000002RemoteB EDD Series card Port 1 L2CP Mode
0180C2000002
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.847 |
| eddL2CPPort1DMAC0180C2000003RemoteB EDD Series card Port 1 L2CP Mode
0180C2000003
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.848 |
| eddL2CPPort1DMAC0180C2000004RemoteB EDD Series card Port 1 L2CP Mode
0180C2000004
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.849 |
| edduRingInst1typeRemoteB EDD Series card u-Ring instance1 type
0: u-Ring
1: Sub-Ring
2: u-Chain | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.85 |
| eddL2CPPort1DMAC0180C2000005RemoteB EDD Series card Port 1 L2CP Mode
0180C2000005
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.850 |
| eddL2CPPort1DMAC0180C2000006RemoteB EDD Series card Port 1 L2CP Mode
0180C2000006
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.851 |
| eddL2CPPort1DMAC0180C2000007RemoteB EDD Series card Port 1 L2CP Mode
0180C2000007
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.852 |
| eddL2CPPort1DMAC0180C2000008RemoteB EDD Series card Port 1 L2CP Mode
0180C2000008
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.853 |
| eddL2CPPort1DMAC0180C2000009RemoteB EDD Series card Port 1 L2CP Mode
0180C2000009
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.854 |
| eddL2CPPort1DMAC0180C200000ARemoteB EDD Series card Port 1 L2CP Mode
0180C200000A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.855 |
| eddL2CPPort1DMAC0180C200000BRemoteB EDD Series card Port 1 L2CP Mode
0180C200000B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.856 |
| eddL2CPPort1DMAC0180C200000CRemoteB EDD Series card Port 1 L2CP Mode
0180C200000C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.857 |
| eddL2CPPort1DMAC0180C200000DRemoteB EDD Series card Port 1 L2CP Mode
0180C200000D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.858 |
| eddL2CPPort1DMAC0180C200000ERemoteB EDD Series card Port 1 L2CP Mode
0180C200000E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.859 |
| edduRingInst1masterRemoteB EDD Series card u-Ring instance1 master
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.86 |
| eddL2CPPort1DMAC0180C200000FRemoteB EDD Series card Port 1 L2CP Mode
0180C200000F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.860 |
| eddL2CPPort1DMAC0180C2000010RemoteB EDD Series card Port 1 L2CP Mode
0180C2000010
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.861 |
| eddL2CPPort1DMAC0180C2000020RemoteB EDD Series card Port 1 L2CP Mode
0180C2000020
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.862 |
| eddL2CPPort1DMAC0180C2000021RemoteB EDD Series card Port 1 L2CP Mode
0180C2000021
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.863 |
| eddL2CPPort1DMAC0180C2000022RemoteB EDD Series card Port 1 L2CP Mode
0180C2000022
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.864 |
| eddL2CPPort1DMAC0180C2000023RemoteB EDD Series card Port 1 L2CP Mode
0180C2000023
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.865 |
| eddL2CPPort1DMAC0180C2000024RemoteB EDD Series card Port 1 L2CP Mode
0180C2000024
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.866 |
| eddL2CPPort1DMAC0180C2000025RemoteB EDD Series card Port 1 L2CP Mode
0180C2000025
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.867 |
| eddL2CPPort1DMAC0180C2000026RemoteB EDD Series card Port 1 L2CP Mode
0180C2000026
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.868 |
| eddL2CPPort1DMAC0180C2000027RemoteB EDD Series card Port 1 L2CP Mode
0180C2000027
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.869 |
| edduRingInst1EastPortRemoteB EDD Series card u-Ring instance1 east port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.87 |
| eddL2CPPort1DMAC0180C2000028RemoteB EDD Series card Port 1 L2CP Mode
0180C2000028
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.870 |
| eddL2CPPort1DMAC0180C2000029RemoteB EDD Series card Port 1 L2CP Mode
0180C2000029
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.871 |
| eddL2CPPort1DMAC0180C200002ARemoteB EDD Series card Port 1 L2CP Mode
0180C200002A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.872 |
| eddL2CPPort1DMAC0180C200002BRemoteB EDD Series card Port 1 L2CP Mode
0180C200002B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.873 |
| eddL2CPPort1DMAC0180C200002CRemoteB EDD Series card Port 1 L2CP Mode
0180C200002C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.874 |
| eddL2CPPort1DMAC0180C200002DRemoteB EDD Series card Port 1 L2CP Mode
0180C200002D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.875 |
| eddL2CPPort1DMAC0180C200002ERemoteB EDD Series card Port 1 L2CP Mode
0180C200002E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.876 |
| eddL2CPPort1DMAC0180C200002FRemoteB EDD Series card Port 1 L2CP Mode
0180C200002F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.877 |
| eddL2CPPort2DMAC0180C2000000RemoteB EDD Series card Port 2 L2CP Mode
0180C2000000
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.878 |
| eddL2CPPort2DMAC0180C2000001RemoteB EDD Series card Port 2 L2CP Mode
0180C2000001
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.879 |
| edduRingInst1EastEdgeRemoteB EDD Series card u-Ring instance1 east edge
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.88 |
| eddL2CPPort2DMAC0180C2000002RemoteB EDD Series card Port 2 L2CP Mode
0180C2000002
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.880 |
| eddL2CPPort2DMAC0180C2000003RemoteB EDD Series card Port 2 L2CP Mode
0180C2000003
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.881 |
| eddL2CPPort2DMAC0180C2000004RemoteB EDD Series card Port 2 L2CP Mode
0180C2000004
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.882 |
| eddL2CPPort2DMAC0180C2000005RemoteB EDD Series card Port 2 L2CP Mode
0180C2000005
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.883 |
| eddL2CPPort2DMAC0180C2000006RemoteB EDD Series card Port 2 L2CP Mode
0180C2000006
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.884 |
| eddL2CPPort2DMAC0180C2000007RemoteB EDD Series card Port 2 L2CP Mode
0180C2000007
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.885 |
| eddL2CPPort2DMAC0180C2000008RemoteB EDD Series card Port 2 L2CP Mode
0180C2000008
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.886 |
| eddL2CPPort2DMAC0180C2000009RemoteB EDD Series card Port 2 L2CP Mode
0180C2000009
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.887 |
| eddL2CPPort2DMAC0180C200000ARemoteB EDD Series card Port 2 L2CP Mode
0180C200000A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.888 |
| eddL2CPPort2DMAC0180C200000BRemoteB EDD Series card Port 2 L2CP Mode
0180C200000B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.889 |
| edduRingInst1WestPortRemoteB EDD Series card u-Ring instance1 west port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.89 |
| eddL2CPPort2DMAC0180C200000CRemoteB EDD Series card Port 2 L2CP Mode
0180C200000C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.890 |
| eddL2CPPort2DMAC0180C200000DRemoteB EDD Series card Port 2 L2CP Mode
0180C200000A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.891 |
| eddL2CPPort2DMAC0180C200000ERemoteB EDD Series card Port 2 L2CP Mode
0180C200000E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.892 |
| eddL2CPPort2DMAC0180C200000FRemoteB EDD Series card Port 2 L2CP Mode
0180C200000F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.893 |
| eddL2CPPort2DMAC0180C2000010RemoteB EDD Series card Port 2 L2CP Mode
0180C2000010
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.894 |
| eddL2CPPort2DMAC0180C2000020RemoteB EDD Series card Port 2 L2CP Mode
0180C2000020
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.895 |
| eddL2CPPort2DMAC0180C2000021RemoteB EDD Series card Port 2 L2CP Mode
0180C2000021
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.896 |
| eddL2CPPort2DMAC0180C2000022RemoteB EDD Series card Port 2 L2CP Mode
0180C2000022
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.897 |
| eddL2CPPort2DMAC0180C2000023RemoteB EDD Series card Port 2 L2CP Mode
0180C2000023
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.898 |
| eddL2CPPort2DMAC0180C2000024RemoteB EDD Series card Port 2 L2CP Mode
0180C2000024
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.899 |
| eddPort1SpeedstsRemoteB EDD Series card Port1 speed status
10Base-T
100Base-Tx
1000Base-Tx
2.5G | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.9 |
| edduRingInst1WestEdgeRemoteB EDD Series card u-Ring instance1 west edge
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.90 |
| eddL2CPPort2DMAC0180C2000025RemoteB EDD Series card Port 2 L2CP Mode
0180C2000025
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.900 |
| eddL2CPPort2DMAC0180C2000026RemoteB EDD Series card Port 2 L2CP Mode
0180C2000026
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.901 |
| eddL2CPPort2DMAC0180C2000027RemoteB EDD Series card Port 2 L2CP Mode
0180C2000027
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.902 |
| eddL2CPPort2DMAC0180C2000028RemoteB EDD Series card Port 2 L2CP Mode
0180C2000028
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.903 |
| eddL2CPPort2DMAC0180C2000029RemoteB EDD Series card Port 2 L2CP Mode
0180C2000029
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.904 |
| eddL2CPPort2DMAC0180C200002ARemoteB EDD Series card Port 2 L2CP Mode
0180C200002A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.905 |
| eddL2CPPort2DMAC0180C200002BRemoteB EDD Series card Port 2 L2CP Mode
0180C200002B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.906 |
| eddL2CPPort2DMAC0180C200002CRemoteB EDD Series card Port 2 L2CP Mode
0180C200002C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.907 |
| eddL2CPPort2DMAC0180C200002DRemoteB EDD Series card Port 2 L2CP Mode
0180C200002D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.908 |
| eddL2CPPort2DMAC0180C200002ERemoteB EDD Series card Port 2 L2CP Mode
0180C200002E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.909 |
| edduRingInst2IDRemoteB EDD Series card u-Ring instance2 ID | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.91 |
| eddL2CPPort2DMAC0180C200002FRemoteB EDD Series card Port 2 L2CP Mode
0180C200002F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.910 |
| eddL2CPPort3DMAC0180C2000000RemoteB EDD Series card Port 3 L2CP Mode
0180C2000000
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.911 |
| eddL2CPPort3DMAC0180C2000001RemoteB EDD Series card Port 3 L2CP Mode
0180C2000001
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.912 |
| eddL2CPPort3DMAC0180C2000002RemoteB EDD Series card Port 3 L2CP Mode
0180C2000002
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.913 |
| eddL2CPPort3DMAC0180C2000003RemoteB EDD Series card Port 3 L2CP Mode
0180C2000003
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.914 |
| eddL2CPPort3DMAC0180C2000004RemoteB EDD Series card Port 3 L2CP Mode
0180C2000004
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.915 |
| eddL2CPPort3DMAC0180C2000005RemoteB EDD Series card Port 3 L2CP Mode
0180C2000005
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.916 |
| eddL2CPPort3DMAC0180C2000006RemoteB EDD Series card Port 3 L2CP Mode
0180C2000006
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.917 |
| eddL2CPPort3DMAC0180C2000007RemoteB EDD Series card Port 3 L2CP Mode
0180C2000007
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.918 |
| eddL2CPPort3DMAC0180C2000008RemoteB EDD Series card Port 3 L2CP Mode
0180C2000008
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.919 |
| edduRingInst2typeRemoteB EDD Series card u-Ring instance2 type
0: u-Ring
1: Sub-Ring
2: u-Chain | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.92 |
| eddL2CPPort3DMAC0180C2000009RemoteB EDD Series card Port 3 L2CP Mode
0180C2000009
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.920 |
| eddL2CPPort3DMAC0180C200000ARemoteB EDD Series card Port 3 L2CP Mode
0180C200000A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.921 |
| eddL2CPPort3DMAC0180C200000BRemoteB EDD Series card Port 3 L2CP Mode
0180C200000B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.922 |
| eddL2CPPort3DMAC0180C200000CRemoteB EDD Series card Port 3 L2CP Mode
0180C200000C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.923 |
| eddL2CPPort3DMAC0180C200000DRemoteB EDD Series card Port 3 L2CP Mode
0180C200000D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.924 |
| eddL2CPPort3DMAC0180C200000ERemoteB EDD Series card Port 3 L2CP Mode
0180C200000E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.925 |
| eddL2CPPort3DMAC0180C200000FRemoteB EDD Series card Port 3 L2CP Mode
0180C200000F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.926 |
| eddL2CPPort3DMAC0180C2000010RemoteB EDD Series card Port 3 L2CP Mode
0180C2000010
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.927 |
| eddL2CPPort3DMAC0180C2000020RemoteB EDD Series card Port 3 L2CP Mode
0180C2000020
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.928 |
| eddL2CPPort3DMAC0180C2000021RemoteB EDD Series card Port 3 L2CP Mode
0180C2000021
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.929 |
| edduRingInst2masterRemoteB EDD Series card u-Ring instance2 master
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.93 |
| eddL2CPPort3DMAC0180C2000022RemoteB EDD Series card Port 3 L2CP Mode
0180C2000022
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.930 |
| eddL2CPPort3DMAC0180C2000023RemoteB EDD Series card Port 3 L2CP Mode
0180C2000023
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.931 |
| eddL2CPPort3DMAC0180C2000024RemoteB EDD Series card Port 3 L2CP Mode
0180C2000024
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.932 |
| eddL2CPPort3DMAC0180C2000025RemoteB EDD Series card Port 3 L2CP Mode
0180C2000025
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.933 |
| eddL2CPPort3DMAC0180C2000026RemoteB EDD Series card Port 3 L2CP Mode
0180C2000026
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.934 |
| eddL2CPPort3DMAC0180C2000027RemoteB EDD Series card Port 3 L2CP Mode
0180C2000027
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.935 |
| eddL2CPPort3DMAC0180C2000028RemoteB EDD Series card Port 3 L2CP Mode
0180C2000028
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.936 |
| eddL2CPPort3DMAC0180C2000029RemoteB EDD Series card Port 3 L2CP Mode
0180C2000029
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.937 |
| eddL2CPPort3DMAC0180C200002ARemoteB EDD Series card Port 3 L2CP Mode
0180C200002A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.938 |
| eddL2CPPort3DMAC0180C200002BRemoteB EDD Series card Port 3 L2CP Mode
0180C200002B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.939 |
| edduRingInst2EastPortRemoteB EDD Series card u-Ring instance2 east port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.94 |
| eddL2CPPort3DMAC0180C200002CRemoteB EDD Series card Port 3 L2CP Mode
0180C200002C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.940 |
| eddL2CPPort3DMAC0180C200002DRemoteB EDD Series card Port 3 L2CP Mode
0180C200002D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.941 |
| eddL2CPPort3DMAC0180C200002ERemoteB EDD Series card Port 3 L2CP Mode
0180C200002E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.942 |
| eddL2CPPort3DMAC0180C200002FRemoteB EDD Series card Port 3 L2CP Mode
0180C200002F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.943 |
| eddL2CPPort4DMAC0180C2000000RemoteB EDD Series card Port 4 L2CP Mode
0180C2000000
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.944 |
| eddL2CPPort4DMAC0180C2000001RemoteB EDD Series card Port 4 L2CP Mode
0180C2000001
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.945 |
| eddL2CPPort4DMAC0180C2000002RemoteB EDD Series card Port 4 L2CP Mode
0180C2000002
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.946 |
| eddL2CPPort4DMAC0180C2000003RemoteB EDD Series card Port 4 L2CP Mode
0180C2000003
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.947 |
| eddL2CPPort4DMAC0180C2000004RemoteB EDD Series card Port 4 L2CP Mode
0180C2000004
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.948 |
| eddL2CPPort4DMAC0180C2000005RemoteB EDD Series card Port 4 L2CP Mode
0180C2000005
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.949 |
| edduRingInst2EastEdgeRemoteB EDD Series card u-Ring instance2 east edge
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.95 |
| eddL2CPPort4DMAC0180C2000006RemoteB EDD Series card Port 4 L2CP Mode
0180C2000006
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.950 |
| eddL2CPPort4DMAC0180C2000007RemoteB EDD Series card Port 4 L2CP Mode
0180C2000007
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.951 |
| eddL2CPPort4DMAC0180C2000008RemoteB EDD Series card Port 4 L2CP Mode
0180C2000008
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.952 |
| eddL2CPPort4DMAC0180C2000009RemoteB EDD Series card Port 4 L2CP Mode
0180C2000009
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.953 |
| eddL2CPPort4DMAC0180C200000ARemoteB EDD Series card Port 4 L2CP Mode
0180C200000A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.954 |
| eddL2CPPort4DMAC0180C200000BRemoteB EDD Series card Port 4 L2CP Mode
0180C200000B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.955 |
| eddL2CPPort4DMAC0180C200000CRemoteB EDD Series card Port 4 L2CP Mode
0180C200000C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.956 |
| eddL2CPPort4DMAC0180C200000DRemoteB EDD Series card Port 4 L2CP Mode
0180C200000D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.957 |
| eddL2CPPort4DMAC0180C200000ERemoteB EDD Series card Port 4 L2CP Mode
0180C200000E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.958 |
| eddL2CPPort4DMAC0180C200000FRemoteB EDD Series card Port 4 L2CP Mode
0180C200000F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.959 |
| edduRingInst2WestPortRemoteB EDD Series card u-Ring instance2 west port | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.96 |
| eddL2CPPort4DMAC0180C2000010RemoteB EDD Series card Port 4 L2CP Mode
0180C2000010
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.960 |
| eddL2CPPort4DMAC0180C2000020RemoteB EDD Series card Port 4 L2CP Mode
0180C2000020
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.961 |
| eddL2CPPort4DMAC0180C2000021RemoteB EDD Series card Port 4 L2CP Mode
0180C2000021
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.962 |
| eddL2CPPort4DMAC0180C2000022RemoteB EDD Series card Port 4 L2CP Mode
0180C2000022
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.963 |
| eddL2CPPort4DMAC0180C2000023RemoteB EDD Series card Port 4 L2CP Mode
0180C2000023
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.964 |
| eddL2CPPort4DMAC0180C2000024RemoteB EDD Series card Port 4 L2CP Mode
0180C2000024
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.965 |
| eddL2CPPort4DMAC0180C2000025RemoteB EDD Series card Port 4 L2CP Mode
0180C2000025
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.966 |
| eddL2CPPort4DMAC0180C2000026RemoteB EDD Series card Port 4 L2CP Mode
0180C2000026
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.967 |
| eddL2CPPort4DMAC0180C2000027RemoteB EDD Series card Port 4 L2CP Mode
0180C2000027
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.968 |
| eddL2CPPort4DMAC0180C2000028RemoteB EDD Series card Port 4 L2CP Mode
0180C2000028
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.969 |
| edduRingInst2WestEdgeRemoteB EDD Series card u-Ring instance2 west edge
0: No
1: Yes | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.97 |
| eddL2CPPort4DMAC0180C2000029RemoteB EDD Series card Port 4 L2CP Mode
0180C2000029
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.970 |
| eddL2CPPort4DMAC0180C200002ARemoteB EDD Series card Port 4 L2CP Mode
0180C200002A
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.971 |
| eddL2CPPort4DMAC0180C200002BRemoteB EDD Series card Port 4 L2CP Mode
0180C200002B
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.972 |
| eddL2CPPort4DMAC0180C200002CRemoteB EDD Series card Port 4 L2CP Mode
0180C200002C
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.973 |
| eddL2CPPort4DMAC0180C200002DRemoteB EDD Series card Port 4 L2CP Mode
0180C200002D
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.974 |
| eddL2CPPort4DMAC0180C200002ERemoteB EDD Series card Port 4 L2CP Mode
0180C200002E
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.975 |
| eddL2CPPort4DMAC0180C200002FRemoteB EDD Series card Port 4 L2CP Mode
0180C200002F
0: Forward
1: Peer | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.976 |
| eddPort1MEPInstanceRemoteB EDD Series card Port 1 MEP Instance
'MEP ID' must be an integer value between 0 and 8191. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.977 |
| eddPort1MEPLogicRemoteB EDD Series card Port 1 MEP Logic
0: And
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.978 |
| eddPort2MEPInstanceRemoteB EDD Series card Port 2 MEP Instance
'MEP ID' must be an integer value between 0 and 8191. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.979 |
| edduRingInst1IDstsRemoteB EDD Series card u-Ring Instance1 ID status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.98 |
| eddPort2MEPLogicRemoteB EDD Series card Port 2 MEP Logic
0: And
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.980 |
| eddPort3MEPInstanceRemoteB EDD Series card Port 3 MEP Instance
'MEP ID' must be an integer value between 0 and 8191. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.981 |
| eddPort3MEPLogicRemoteB EDD Series card Port 3 MEP Logic
0: And
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.982 |
| eddPort4MEPInstanceRemoteB EDD Series card Port 4 MEP Instance
'MEP ID' must be an integer value between 0 and 8191. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.983 |
| eddPort4MEPLogicRemoteB EDD Series card Port 4 MEP Logic
0: And
1: OR | column | Enumeration | .1.3.6.1.4.1.4756.20.442.20.1.984 |
| edduRingInst1typestsRemoteB EDD Series card u-Ring Type status | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.442.20.1.99 |