chassisIndex
CTC-FRM220-MIB ·
.1.3.6.1.4.1.4756.20.30.1.1
Object
column
Integer32
A unique value for each chassis.
Context
- MIB
- CTC-FRM220-MIB
- OID
.1.3.6.1.4.1.4756.20.30.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- snmpEntry
- Table
- snmpTable
- Siblings
- 35
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| user1UtpLinkDNLocal User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Local Utp Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.10 |
| user1FxLinkDNLocal User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Local Fx Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.11 |
| user1FEFLocal User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when FEF is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.12 |
| user1RemoPWRABLocal User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Remote Power is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.13 |
| user1FxLinkDNRemote User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Remote Fx Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.14 |
| user1UtpLinkDNRemote User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Remote Utp Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.15 |
| user2Power1 User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when power 1 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.16 |
| user2Power2 User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when power 2 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.17 |
| user2Fan1 User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when fan 1 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.18 |
| user2Fan2 User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when fan 2 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.19 |
| redundancy FRM220 Card redundancy mode :
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.2 |
| user2UtpLinkDNLocal User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Utp Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.20 |
| user2FxLinkDNLocal User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Fx link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.21 |
| user2FEFLocal User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when FEF is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.22 |
| user2RemoPWRABLocal User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Remote Power is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.23 |
| user2FxLinkDNRemote User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Fx Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.24 |
| user2UtpLinkDNRemote User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Utp Link Down is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.25 |
| user1SignalLossLocal User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Signal Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.26 |
| user1SignalLossRemote User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Signal Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.27 |
| user2SignalLossLocal User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Signal Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.28 |
| user2SignalLossRemote User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Signal Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.29 |
| serialNumber SNMP card Serial Number | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.4756.20.30.1.3 |
| remotedevicepolling Remote Device Polling: (for chassis to chassis management)
0:Disable
1:Enable | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.30 |
| fan1Type fan 1 Type:
0:Normal
1:High | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.31 |
| fan2Type fan 2 Type:
0:Normal
1:High | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.32 |
| user1SyncLossLocal User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Sync Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.33 |
| user1SyncLossRemote User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when Sync Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.34 |
| user2SyncLossLocal User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Sync Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.35 |
| user2SyncLossRemote User definition #2 for Alarm 2:
0:No defined
1:Alarm 2 is active when Sync Loss is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.36 |
| alarm1Mode Alarm 1 mode:
0:Disable
1:Active if any power fails (default)
2:Active if any user#1 definition is met
3:Force active for manual testing | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.4 |
| alarm2Mode Alarm 2 mode:
0:Disable
1:Active if any fan fails (default)
2:Active if any user#2 definition is met
3:Force active for manual testing | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.5 |
| user1Power1 User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when power 1 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.6 |
| user1Power2 User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when power 2 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.7 |
| user1Fan1 User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when fan 1 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.8 |
| user1Fan2 User definition #1 for Alarm 1:
0:No defined
1:Alarm 1 is active when fan 2 is failure | column | Enumeration | .1.3.6.1.4.1.4756.20.30.1.9 |