cpqSsRaidSystemStatus

CPQSTSYS-MIB · .1.3.6.1.4.1.232.8.4.1.1.3

Object

column mandatory Enumeration
RAID Storage System Status.
              
This is the current status of the RAID Storage System.
This value will be one of the following:
              
   other(1)
     Indicates that the agent does not recognize the state of the
     RAID Storage System.  You may need to upgrade the agent.
              
   agentNotRunning(2)
     Indicates that the Storage Work agent is not running.  You need
     to restart the Storage Work agent.
              
   good(3)
     Indicates that the system is operating properly.
              
   warning(4)
     At least one component of the system failed.
              
   communicationLoss(5)
     The RAID Storage System has a cable or communication problem.
     Please check all cable connects to the host server.

Context

MIB
CPQSTSYS-MIB
OID
.1.3.6.1.4.1.232.8.4.1.1.3
Type
column
Access
readonly
Status
mandatory
Parent
cpqSsRaidSystemEntry
Table
cpqSsRaidSystemTable
Siblings
5

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2agentNotRunning
3good
4warning
5communicationLoss

Related Objects