cpqSsPowerSupplySerialNumber
CPQSTSYS-MIB ·
.1.3.6.1.4.1.232.8.2.2.3.1.7
Object
column
mandatory
OctetString
Storage System Power Supply Serial Number.
This is the power supply's serial number. This can be used
for identification purposes. If the serial number is not supported,
the agent will return a NULL string.
Context
- MIB
- CPQSTSYS-MIB
- OID
.1.3.6.1.4.1.232.8.2.2.3.1.7- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqSsPowerSupplyEntry
- Table
- cpqSsPowerSupplyTable
- Siblings
- 8
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-24
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqSsPowerSupplyChassisIndex mandatory Storage System Power Supply Chassis Index.
The chassis index uniquely identifies a storage system chassis. | column | Integer32 | .1.3.6.1.4.1.232.8.2.2.3.1.1 |
| cpqSsPowerSupplyIndex mandatory Storage System Power Supply Bay.
This index uniquely identifies a power supply bay. | column | Integer32 | .1.3.6.1.4.1.232.8.2.2.3.1.2 |
| cpqSsPowerSupplyBay mandatory Storage System Power Supply Bay.
The following values are defined:
other(1)
The agent does not recognize the bay. You may need to upgrade
… | column | Enumeration | .1.3.6.1.4.1.232.8.2.2.3.1.3 |
| cpqSsPowerSupplyStatus mandatory Storage System Power Supply Status.
The following values are defined:
other(1)
The agent is unable to determine if this storage system power
… | column | Enumeration | .1.3.6.1.4.1.232.8.2.2.3.1.4 |
| cpqSsPowerSupplyUpsStatus mandatory Storage System Power Supply Uninterruptible Power Supply (UPS)
Status.
The following values are defined:
other(1)
The agent is unable to d… | column | Enumeration | .1.3.6.1.4.1.232.8.2.2.3.1.5 |
| cpqSsPowerSupplyCondition mandatory Storage System Power Supply Condition.
This is the condition of the storage system chassis and all of
its components. The following values are defined:
… | column | Enumeration | .1.3.6.1.4.1.232.8.2.2.3.1.6 |
| cpqSsPowerSupplyBoardRevision mandatory Storage System Power Supply Board Revision.
This is the power supply board revision. If the board revision is
not supported, the agent will return a NULL string. | column | OctetString | .1.3.6.1.4.1.232.8.2.2.3.1.8 |
| cpqSsPowerSupplyFirmwareRevision mandatory Storage System Power Supply Firmware Revision.
This is the power supply firmware revision. If the firmware revision
is not supported, the agent will return a NULL … | column | OctetString | .1.3.6.1.4.1.232.8.2.2.3.1.9 |