cpqSiRackEnclosureMgrSerialNumber
CPQSINFO-MIB ·
.1.3.6.1.4.1.232.2.2.13.1.1.6
Object
The serial number of the enclosure.
The string will be empty if the enclosure does not report the
information or it could not be determined.
Context
- MIB
- CPQSINFO-MIB
- OID
.1.3.6.1.4.1.232.2.2.13.1.1.6- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqSiRackEnclosureMgrEntry
- Table
- cpqSiRackEnclosureMgrTable
- Siblings
- 12
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqSiRackEnclosureMgrIndex mandatory A locally-unique index value. | column | Integer32 | .1.3.6.1.4.1.232.2.2.13.1.1.1 |
| cpqSiRackEnclosureMgrProductID optional The Enclosure product identifier. The string will be empty
if it could not be determined. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.10 |
| cpqSiRackEnclosureMgrUUID optional The Enclosure unique identifier. The string will be empty
if it could not be determined. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.11 |
| cpqSiRackEnclosureMgrMatrix mandatory Value 0 not configured in a BladeSystem Matrix environment.
1 configured in a BladeSystem Matrix environment. | column | Integer32 | .1.3.6.1.4.1.232.2.2.13.1.1.12 |
| cpqSiRackEnclosureMgrMatrixID optional Value BladeSystem Matrix vX.Y.Z Where
X major version.
Y minor version.
Z update version.
Is only valid if cpqSiRackEnclosureMgrMatrix value is a 1.
By default is NULL | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.13 |
| cpqSiRackEnclosureMgrType mandatory This value specifies the type of enclosure management.
other(1)
When the type not be determined.
noEnclosureManagement(2)
The server is part of a… | column | Enumeration | .1.3.6.1.4.1.232.2.2.13.1.1.2 |
| cpqSiRackEnclosureMgrIpAddr mandatory The IP address of the rack enclosure manager.
The string will be empty if the enclosure does not report the
information or it could not be determined. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.3 |
| cpqSiRackEnclosureMgrWebLink mandatory The web link to the enclosure managers web based management
information for the enclosure.
The string will be empty if the enclosure does not report the
information… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.4 |
| cpqSiRackEnclosureMgrCondition mandatory The overall condition of the Enclosure. For more detailed
status information, follow the cpqSiEnclosureMgrWebLink through
the Web Management Agent interface.
other… | column | Enumeration | .1.3.6.1.4.1.232.2.2.13.1.1.5 |
| cpqSiRackEnclosureMgrModel optional The model name of the enclosure.
The string will be empty if it could not be determined. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.7 |
| cpqSiRackEnclosureMgrName optional The name of the enclosure. This name logically groups together the
Blade servers installed in the same enclosure and it is shared
with the other servers in the enclosure.
The st… | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.8 |
| cpqSiRackEnclosureMgrFwRev optional The Firmware revision of the Enclosure Manager/Onboard Administrator.
The string will be empty if it could not be determined. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.2.2.13.1.1.9 |