cpqSiMonitorOverallCondition

CPQSINFO-MIB · .1.3.6.1.4.1.232.2.2.8.1

Object

scalar mandatory Enumeration
This value specifies the overall condition of the system`s
monitor(s).
          
The following conditions are supported:
          
other(1)
  The monitor does not support fault reporting or condition is
  unknown.
          
ok(2)
  The monitor is operating OK.
          
degraded(3)
  The monitor has detected a fault.  The monitor is still useable
  but action should be taken to return the monitor to ok.
          
failed(4)
  The monitor has detected a fault.  The monitor will not
  be useable. Action should be taken to replace the monitor.

Context

MIB
CPQSINFO-MIB
OID
.1.3.6.1.4.1.232.2.2.8.1
Type
scalar
Access
readonly
Status
mandatory
Parent
cpqSiMonitor
Siblings
1

Syntax

Enumeration

Values & Constraints

Enumerated Values
1other
2ok
3degraded
4failed

Related Objects

Sibling Objects