cpqSiHotPlugSlotErrorStatus

CPQSINFO-MIB · .1.3.6.1.4.1.232.2.2.9.4.1.6

Object

column mandatory Enumeration
This value specifies the status of the hot plug slot.
              
The hot plug slot status is set as follows:
              
noError(1)
  The slot is operating normally.
              
generalError(2)
  A general error occurred.
              
wrongRevision(3)
  The revision of the replacement adapter was different from
  the original adapter.
              
wrongBoard(4)
  The model of the replacement adapter was different from the
  original adapter.
              
cannotConfig(5)
  The adapter could not be configured.
              
powerFault(6)
  A power fault occurred for the slot.
              
unexpectedPowerLoss(7)
  Power was unexpectedly lost from the slot.
              
wrongSpeed(8)
  The adapter cannot be run at the current bus speed.
              
functionlFailure(9)
  The adapter is not functioning correctly.  This may
  be caused by a cabling problem.

Context

MIB
CPQSINFO-MIB
OID
.1.3.6.1.4.1.232.2.2.9.4.1.6
Type
column
Access
readonly
Status
mandatory
Parent
cpqSiHotPlugSlotEntry
Table
cpqSiHotPlugSlotTable
Siblings
6

Syntax

Enumeration

Values & Constraints

Enumerated Values
1noError
2generalError
3wrongRevision
4wrongBoard
5cannotConfig
6powerFault
7unexpectedPowerLoss
8wrongSpeed
9functionalFailure