cpqRackThermalControllerCDUFlowSensor
CPQRACK-MIB ·
.1.3.6.1.4.1.232.22.2.9.1.1.1.24
Object
column
mandatory
Enumeration
Flow sensor to CDU
Context
- MIB
- CPQRACK-MIB
- OID
.1.3.6.1.4.1.232.22.2.9.1.1.1.24- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqRackThermalControllerEntry
- Table
- cpqRackThermalControllerTable
- Siblings
- 35
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | low |
2 | high |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqRackThermalControllerIndex mandatory A number that uniquely specifies this thermal controller in the rack. | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.1 |
| cpqRackThermalControllerDoorControlRear2 mandatory 1 to open rear door | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.10 |
| cpqRackThermalControllerAirTempSensorFront1 mandatory Front air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.11 |
| cpqRackThermalControllerAirTempSensorFront2 mandatory Front air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.12 |
| cpqRackThermalControllerAirTempSensorFront3 mandatory Front air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.13 |
| cpqRackThermalControllerAirTempSensorFront4 mandatory Front air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.14 |
| cpqRackThermalControllerAirTempSensorRear1 mandatory Rear air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.15 |
| cpqRackThermalControllerAirTempSensorRear2 mandatory Rear air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.16 |
| cpqRackThermalControllerAirTempSensorRear3 mandatory Rear air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.17 |
| cpqRackThermalControllerAirTempSensorRear4 mandatory Rear air temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.18 |
| cpqRackThermalControllerControlValveSupply mandatory Supply valve status | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.19 |
| cpqRackThermalControllerLeakDetect1 mandatory TRUE if sensor 1 detected a leak | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.2 |
| cpqRackThermalControllerControlValveReturn mandatory Return valve status | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.20 |
| cpqRackThermalControllerWaterTempSupply mandatory Water temperature supply in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.21 |
| cpqRackThermalControllerWaterTempReturn mandatory Water temperature return in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.22 |
| cpqRackThermalControllerITFlowSensor mandatory Flow sensor to IT equipment | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.23 |
| cpqRackThermalControllerWaterPressureSupply mandatory Supply water pressure | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.25 |
| cpqRackThermalControllerWaterPressureReturn mandatory Return water pressure | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.26 |
| cpqRackThermalControllerARPO mandatory Emergency power off status | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.27 |
| cpqRackThermalControllerChassisRopeSensor1 mandatory Leak detected by rope sensor 1 | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.28 |
| cpqRackThermalControllerChassisRopeSensor2 mandatory Leak detected by rope sensor 2 | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.29 |
| cpqRackThermalControllerLeakDetect2 mandatory TRUE if sensor 2 detected a leak | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.3 |
| cpqRackThermalControllerChassisRopeSensor3 mandatory Leak detected by rope sensor 3 | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.30 |
| cpqRackThermalControllerChassisRopeSensor4 mandatory Leak detected by rope sensor 4 | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.31 |
| cpqRackThermalControllerOnBoardTemp mandatory Thermal controller board temperature in C | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.32 |
| cpqRackThermalControllerOnBoardHumidity mandatory Environmental relative humidity | column | Integer32 | .1.3.6.1.4.1.232.22.2.9.1.1.1.33 |
| cpqRackThermalControllerBattery mandatory Presence of thermal controller battery | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.34 |
| cpqRackThermalControllerAPMCommunications mandatory APM Communications Status | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.35 |
| cpqRackEnvironmentalTrapDescription mandatory Trap Description including threshold information:
Sensor = string, Lo threshold = integer, Hi threshold = integer | column | OctetString | .1.3.6.1.4.1.232.22.2.9.1.1.1.36 |
| cpqRackThermalControllerLeakDetect3 mandatory TRUE if sensor 3 detected a leak | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.4 |
| cpqRackThermalControllerLeakDetectFacility mandatory TRUE if overhead sensor detected a leak | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.5 |
| cpqRackThermalControllerDoorSensorFront mandatory 1 if front door is open | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.6 |
| cpqRackThermalControllerDoorSensorRear mandatory 1 if rear door is open | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.7 |
| cpqRackThermalControllerDoorControlFront mandatory 1 to open front door | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.8 |
| cpqRackThermalControllerDoorControlRear1 mandatory 1 to open rear door | column | Enumeration | .1.3.6.1.4.1.232.22.2.9.1.1.1.9 |