upsEnvRemoteTempUpperLimit
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.3.6.10
Object
scalar
mandatory
r/w
Integer32
The Upper Limit of the remote temperature; if UpsEnvRemoteTemp rises above this value, the UpsRemoteTempBad alarm will occur. This value should be greater than UpsEnvRemoteTempLowerLimit.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.3.6.10- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- upsEnvironment
- Siblings
- 11
Syntax
Integer32
Values & Constraints
Object Constraints
range: -100-200
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsEnvAmbientTemp mandatory The reading of the ambient temperature in the vicinity of the
UPS or SNMP agent. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.1 |
| upsEnvRemoteHumidityLowerLimit mandatory The Lower Limit of the remote humidity reading; if UpsEnvRemoteHumidity
falls below this value, the UpsRemoteHumidityBad alarm will occur. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.11 |
| upsEnvRemoteHumidityUpperLimit mandatory The Upper Limit of the remote humidity reading; if UpsEnvRemoteHumidity
rises above this value, the UpsRemoteHumidityBad alarm will occur.
This value should be greater than UpsEn… | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.12 |
| upsEnvAmbientLowerLimit mandatory The Lower Limit of the ambient temperature; if UpsEnvAmbientTemp
falls below this value, the UpsAmbientTempBad alarm will occur. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.2 |
| upsEnvAmbientUpperLimit mandatory The Upper Limit of the ambient temperature; if UpsEnvAmbientTemp
rises above this value, the UpsAmbientTempBad alarm will occur.
This value should be greater than UpsEnvAmbientLo… | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.3 |
| upsEnvAmbientHumidity mandatory The reading of the ambient humidity in the vicinity of the
UPS or SNMP agent. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.4 |
| upsEnvRemoteTemp mandatory The reading of a remote temperature sensor connected to the
UPS or SNMP agent. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.5 |
| upsEnvRemoteHumidity mandatory The reading of a remote humidity sensor connected to the
UPS or SNMP agent. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.6 |
| upsEnvNumContacts mandatory The number of Contacts in the UpsContactsTable.
This object indicates the number of rows in the
UpsContactsTable. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.7 |
| upsContactsTable mandatory A list of Contact Sensing table entries.
The number of entries is given by the value of
UpsEnvNumContacts. | table | - | .1.3.6.1.4.1.232.165.3.6.8 |
| upsEnvRemoteTempLowerLimit mandatory The Lower Limit of the remote temperature; if UpsEnvRemoteTemp
falls below this value, the UpsRemoteTempBad alarm will occur. | scalar | Integer32 | .1.3.6.1.4.1.232.165.3.6.9 |