pdu3OutletCurrentPercentLoad
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.11.5.1.1.11
Object
column
mandatory
Integer32
Current percent load, based on the rated current capacity. Units are percentage, for example 80.5% will be returned as 805. A negative value indicates that this object is not available.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.11.5.1.1.11- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- pdu3OutletEntry
- Table
- pdu3OutletTable
- Siblings
- 16
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pdu3OutletIndex mandatory Index for each outlet, value from 1 to the number of outlets per PDU. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.1 |
| pdu3OutletActivePowerThUpperCritical mandatory Upper critical threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.10 |
| pdu3OutletVA mandatory A outlet power VA value. Units are VA. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.12 |
| pdu3OutletWatts mandatory A outlet power in Watts value. Units are Watts. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.13 |
| pdu3OutletWh mandatory An energy in kWatt-Hour value for each outlet. Units are kWh.
This object is writable so that it can be reset to 0. When it is
written to, the pdu3OutletWhTimer will be reset up… | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.14 |
| pdu3OutletWhTimer mandatory Timestamp (date and time) of outlet energy in kWh is reset. | column | OctetString | .1.3.6.1.4.1.232.165.11.5.1.1.15 |
| pdu3OutletPowerFactor mandatory An outlet PF value. Return value is divided by 100, for example a power factor
of 0.95 would be returned as 95. A negative value indicates that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.16 |
| pdu3OutletVAR mandatory An outlet power reactive in VAR value. Units are VAR. A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.17 |
| pdu3OutletName mandatory A descriptive name for the outlet. | column | OctetString | .1.3.6.1.4.1.232.165.11.5.1.1.2 |
| pdu3OutletType mandatory Type of this outlet - C13, C19. | column | Enumeration | .1.3.6.1.4.1.232.165.11.5.1.1.3 |
| pdu3OutletCurrentRating mandatory Rated current capacity of this outlet. Return value is divided by 100 to get amps. A negative
value indicates that the hardware current capacity is unknown. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.4 |
| pdu3OutletCurrent mandatory A outlet current measurement value. Return value is divided by 100 to get amps. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.5 |
| pdu3OutletActivePowerThStatus mandatory Status of the measured outlet active power relative to the configured thresholds. | column | Enumeration | .1.3.6.1.4.1.232.165.11.5.1.1.6 |
| pdu3OutletActivePowerThLowerWarning mandatory Lower warning threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.7 |
| pdu3OutletActivePowerThLowerCritical mandatory Lower critical threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.8 |
| pdu3OutletActivePowerThUpperWarning mandatory Upper warning threshold. Units are Watts(W). A negative value indicates
that this object is not available. | column | Integer32 | .1.3.6.1.4.1.232.165.11.5.1.1.9 |