oupsInput
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.6.3
Object
node
No description available.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.6.3- Type
- node
- Parent
- oups
- Siblings
- 5
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oupsIdent | node | - | .1.3.6.1.4.1.232.165.6.1 |
| oupsBattery | node | - | .1.3.6.1.4.1.232.165.6.2 |
| oupsOutput | node | - | .1.3.6.1.4.1.232.165.6.4 |
| oupsMonitor | node | - | .1.3.6.1.4.1.232.165.6.5 |
| oupsRackDiscovery | node | - | .1.3.6.1.4.1.232.165.6.6 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oupsInputFrequency mandatory The utility line frequency in tenths of Hz. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.3.1 |
| oupsInputWithGenerator mandatory A value of 1 when user known for sure Input has no Generator backup; a value
of 2 tells Input Source could be from either Utility or Generator. | scalar | Enumeration | .1.3.6.1.4.1.232.165.6.3.10 |
| oupsInputLineBads mandatory The number of times the Input was out of tolerance
in voltage or frequency. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.3.2 |
| oupsInputNumPhases mandatory | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.3.3 |
| oupsInputTable mandatory Aggregate Object with number of entries equal to
NumPhases and including the UpsInput group. | table | - | .1.3.6.1.4.1.232.165.6.3.4 |
| oupsInputPowerFactor mandatory The measured real Input power factor with 2 decimals. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.3.5 |
| oupsInputDBType mandatory Read the input Distribution Box type: 1- 480V-Y (US-5W NEMA plugs),
2- 480V-V (US-5W IEC plugs), 3- 415V-Y (EURO-5W IEC plugs),
4- 415V-Y (US/INTL-5W IEC plugs), 5- 380V-Y (China-… | scalar | OctetString | .1.3.6.1.4.1.232.165.6.3.6 |
| oupsInputUpperVoltage mandatory Read the upper voltage range, 5 to 10 percent above the nominal voltage.
Factory default is 10 percent. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.3.7 |
| oupsInputLowerVoltage mandatory Read the lower voltage range, 5 to 15 percent below the nominal voltage.
Factory default is -15 percent. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.3.8 |
| oupsGeneratorDetection mandatory ATS sets a value of 1 to signal UPS that a generator is started so the UPS will
charge Battery Pack using a different setting while it's on generator (intent to
save all power … | scalar | Enumeration | .1.3.6.1.4.1.232.165.6.3.9 |