oupsBatChargingPowerLevelGenerator
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.6.2.14
Object
scalar
mandatory
OctetString
4 charging power levels: 1100W, 555W, 190W, No Charge.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.6.2.14- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- oupsBattery
- Siblings
- 16
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-63
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| oupsBatTimeRemaining mandatory Battery run time in seconds before UPS turns off due
to low battery. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.2.1 |
| oupsBatChargeDelay mandatory Get battery charge delay in second. Default is 0 (random)
unit is increased per 10sec. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.2.10 |
| oupsBatNumModules mandatory Number of battery modules detected by power unit. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.2.11 |
| oupsBatModel mandatory Report 1U, 2U, or 3U Battery Pack, both BPs must be the same model. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.12 |
| oupsBatChargingPowerLevelUtility mandatory 3 charging power levels: 1100W, 555W, 190W. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.13 |
| oupsBatSharedConfig mandatory expect 3 values for shared BP configuration: PU single, PU master, PU slave. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.15 |
| oupsBatPackFWVerBP1 mandatory Display Battery Pack 1 FW version. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.16 |
| oupsBatPackFWVerBP2 mandatory Display Battery Pack 2 FW version. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.17 |
| oupsBatVoltage mandatory Read the Total Battery voltage. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.2.2 |
| oupsBatCapacity mandatory Battery percent charge. | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.2.3 |
| oupsBatAbmStatus mandatory Gives the status of the Advanced Battery Management; example:
batteryResting(3) is the state when the battery is fully charged and none of
the other actions (charging/discharging… | scalar | Enumeration | .1.3.6.1.4.1.232.165.6.2.4 |
| oupsBatTestStatus mandatory Battery Test Status. UPS will support schedule testing only
7, 14, 30, or 60 days. Default is 14 days. | scalar | Enumeration | .1.3.6.1.4.1.232.165.6.2.5 |
| oupsBatLatestTestDate mandatory Get time and date of the latest battery test. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.6 |
| oupsBatReplacementDateBP1 mandatory Get the battery replacement date of BP1. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.7 |
| oupsBatReplacementDateBP2 mandatory Get the battery replacement date of BP2. | scalar | OctetString | .1.3.6.1.4.1.232.165.6.2.8 |
| oupsBatToACDelay mandatory Get delay time switching from Battery mode to AC mode in ms.
Default is 0ms, unit is increased per 100ms | scalar | Integer32 | .1.3.6.1.4.1.232.165.6.2.9 |