cpqIdeIdentUltraAtaAvailability
CPQIDE-MIB ·
.1.3.6.1.4.1.232.14.2.2.1.1.11
Object
column
mandatory
Enumeration
This describes the availability of Ultra ATA
transfers between this device and the controller.
The following values are defined:
other(1)
The agents do not support reporting this variable or the
agent need to be upgraded.
noNotSupportedByDeviceAndController(2),
The device and the controller do not support Ultra ATA.
noNotSupportedByDevice(3),
The device does not support Ultra ATA but the controller
does support Ultra ATA.
noNotSupportedByController(4),
The controller does not support Ultra ATA but the device
does support Ultra ATA.
NoDisabledInSetup(5),
The device and the controller do support Ultra ATA but it
has been disabled in F10 Setup.
yesEnabledInSetup(6),
The device and the controller do support Ultra ATA and it
is enabled in F10 Setup.
Context
- MIB
- CPQIDE-MIB
- OID
.1.3.6.1.4.1.232.14.2.2.1.1.11- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqIdeIdentEntry
- Table
- cpqIdeIdentTable
- Siblings
- 10
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | noNotSupportedByDeviceAndController |
3 | noNotSupportedByDevice |
4 | noNotSupportedByController |
5 | noDisabledInSetup |
6 | yesEnabledInSetup |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqIdeIdentIndex mandatory An index that uniquely specifies each device. For disks,
this index value will match the value of the cpqSeFixedDiskIndex
in the Standard Equipment MIB (CPQSTDEQ.MIB) when the sa… | column | Integer32 | .1.3.6.1.4.1.232.14.2.2.1.1.1 |
| cpqIdeIdentStatus mandatory IDE Drive Satus.
This indicates the status of the IDE drive.
The following values are defined:
other(1)
The drive does not support d… | column | Enumeration | .1.3.6.1.4.1.232.14.2.2.1.1.10 |
| cpqIdeIdentModel mandatory IDE Drive Model.
The is the drive model name and can be used for identification
purposes. | column | OctetString | .1.3.6.1.4.1.232.14.2.2.1.1.2 |
| cpqIdeIdentSerNum mandatory IDE Drive Serial Number.
The is the drive serial number and can be used for identification
purposes. | column | OctetString | .1.3.6.1.4.1.232.14.2.2.1.1.3 |
| cpqIdeIdentFWVers mandatory IDE Firmware Version.
This is the version of the firmware on the IDE drive.
If the IDE drive firmware version is unavailable, then this
string will be of length zer… | column | OctetString | .1.3.6.1.4.1.232.14.2.2.1.1.4 |
| cpqIdeIdentCondition obsolete IDE Drive Condition.
This is the overall condition of the IDE drive.
The following values are defined:
other(1)
The drive does not support drive co… | column | Enumeration | .1.3.6.1.4.1.232.14.2.2.1.1.5 |
| cpqIdeIdentErrorNumber mandatory IDE Error Number.
This value represents the error code associated with a failing
IDE drive. | column | OctetString | .1.3.6.1.4.1.232.14.2.2.1.1.6 |
| cpqIdeIdentType mandatory IDE Device Type.
This is the type of ATAPI device. The following types are defined:
other(1)
The Insight agent does not recognize this type.
You… | column | Enumeration | .1.3.6.1.4.1.232.14.2.2.1.1.7 |
| cpqIdeIdentTypeExtended mandatory IDE Extended Device Type.
This is additional information about the type of IDE device.
The following types are defined:
other(1)
This target does n… | column | Enumeration | .1.3.6.1.4.1.232.14.2.2.1.1.8 |
| cpqIdeIdentCondition2 mandatory IDE Drive Condition.
This is the overall condition of the IDE drive.
The following values are defined:
other(1)
The drive does not support drive co… | column | Enumeration | .1.3.6.1.4.1.232.14.2.2.1.1.9 |