cpqHePowerFailureRepairSteps
CPQHLTH-MIB ·
.1.3.6.1.4.1.232.6.2.20.2.1.7
Object
column
mandatory
Enumeration
Recommended troubleshooting steps for a particular device error.
The value will be one of the following:
noError(1)
No errors were detected at this time.
systemBoardRpMsg1(2)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Restore the server to its base
configuration. Attempt to boot the server. (3)If error persists, capture the AHS
logs and contact your support representative for assistance.
processorRpMsg1(3)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Processor
that has an issue. Attempt to boot the server. (3) Swap the faulty Processor with a
known good Processor. Attempt to boot the server. (4) If error persists, capture the AHS
logs and contact your support representative for assistance.
memoryRpMsg1(4)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall all DIMM's in
the memory channel group connected to the CPU that logged the error. Attempt to boot the
server. (3) Swap the first DIMM in the memory channel group with a known good DIMM.
Attempt to boot the server. If the server doesn't boot, repeat step 3 by swapping each
DIMM in the memory channel group, one DIMM at a time until the bad DIMM is found.
(4) If error persists, capture the AHS logs and contact your support representative for
assistance.
memoryBoardRpMsg1(5)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove the cartridge of the Memory
Board that logged the error. Open the cartridge and reseat the DIMM's. Attempt to boot
the server. (3) If error persists, capture the AHS logs and contact your support representative
for assistance.
riserCardAssemblyRpMsg1(6)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Riser Board
that has an issue. Attempt to boot the server. (3) Remove the Riser Board then attempt
to boot the server. (4) If error persists, capture the AHS logs and contact your support
representative for assistance.
flexibleLomRpMsg1(7)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible
LOM that has an issue. Attempt to boot the server. (3) Remove the Flexible LOM then
attempt to boot the server. (4) If error persists, capture the AHS logs and contact your
support representative for assistance.
flexibleSmartArrayRpMsg1(8)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Flexible
Smart Array Controller that has an issue. Attempt to boot the server. (3) Remove the
Flexible Smart Array Controller then attempt to boot the server. (4) If error persists, capture
the AHS logs and contact your support representative for assistance.
optIOPCIeSlotsRpMsg1(9)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Option Card
that has an issue. Attempt to boot the server. (3) Remove all Option Cards from the system.
Attempt to boot the server. (4) If error persists, capture the AHS logs and contact your support
representative for assistance.
powerBackplaneRpMsg1(10)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove GPU power connects one at a time
in order to isolate the bad GPU card, each time attempt to boot the server. (3) If error persists,
capture the AHS logs and contact your support representative for assistance.
sasBackplaneRpMsg1(11)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall Storage
Blackplane that logged the error (including cables). Attempt to boot the server.
(3) If error persists, capture the AHS logs and contact your support representative for assistance.
powerSupplyRpMsg1(12)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Swap the first Power Supply with a
known good Power supply. Attempt to boot the server. (3) If error persists, capture the AHS
logs and contact your support representative for assistance.
mezzCardRpMsg1(13)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Remove and then reinstall the Mezzanine
Card that has an issue. Attempt to boot the server. (3) Remove the Mezzanine Card then
attempt to boot the server. (4) If error persists, capture the AHS logs and contact your
support representative for assistance.
enclosureRpMsg1(14)
Try the following steps until the error no longer occurs:
(1) Remove AC power, then restore AC power. (2) Restore the enclosure to its base
configuration. Attempt to boot the server. (2) If error persists, capture the AHS logs
and contact your support representative for assistance.
Context
- MIB
- CPQHLTH-MIB
- OID
.1.3.6.1.4.1.232.6.2.20.2.1.7- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqHePowerFailureTableEntry
- Table
- cpqHePowerFailureTable
- Siblings
- 7
Syntax
Enumeration
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqHePowerFailureIndex mandatory The index uniquely identifies 1 of 16 areas on the system board. | column | Integer32 | .1.3.6.1.4.1.232.6.2.20.2.1.1 |
| cpqHePowerFailureStatus mandatory The status of this table entry.
The value will be one of the following:
ok(1)
There is no failed device in this area.
failed(2)
A device has fai… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.2 |
| cpqHePowerFailureDeviceID mandatory The unique id of the failed power device on the system board. | column | Integer32 | .1.3.6.1.4.1.232.6.2.20.2.1.3 |
| cpqHePowerFailureArea mandatory This field enumerates the area on the system board.
The value will be one of the following:
systemBoard(1)
General
processor(2)
Processor
memory(3)
… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.4 |
| cpqHePowerFailureDeviceBitMap mandatory The hex representation of the device(s) within the specified area. | column | Integer32 | .1.3.6.1.4.1.232.6.2.20.2.1.5 |
| cpqHePowerFailureGroupString mandatory The location of the device on the system board. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.6.2.20.2.1.6 |
| cpqHePowerFailureType mandatory Critical power failure that occurred.
The value will be one of the following:
noError(1)
No error has occurred.
tempDeadly(2)
The server was shut d… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.8 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| RFC1213-MIBsysName mandatory An administratively-assigned name for this
managed node. By convention, this is the node's
fully-qualified domain name. | scalar | OctetString | .1.3.6.1.2.1.1.5 |
| CPQHOST-MIBcpqHoTrapFlags mandatory The Trap Flags.
This is a collection of flags used during trap delivery.
Each bit has the following meaning:
Bit 5-31: RESERVED: Always 0.
… | scalar | Integer32 | .1.3.6.1.4.1.232.11.2.11.1 |