cpqHePowerFailureIndex
CPQHLTH-MIB ·
.1.3.6.1.4.1.232.6.2.20.2.1.1
Object
column
mandatory
Integer32
The index uniquely identifies 1 of 16 areas on the system board.
Context
- MIB
- CPQHLTH-MIB
- OID
.1.3.6.1.4.1.232.6.2.20.2.1.1- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqHePowerFailureTableEntry
- Table
- cpqHePowerFailureTable
- Siblings
- 7
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqHePowerFailureStatus mandatory The status of this table entry.
The value will be one of the following:
ok(1)
There is no failed device in this area.
failed(2)
A device has fai… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.2 |
| cpqHePowerFailureDeviceID mandatory The unique id of the failed power device on the system board. | column | Integer32 | .1.3.6.1.4.1.232.6.2.20.2.1.3 |
| cpqHePowerFailureArea mandatory This field enumerates the area on the system board.
The value will be one of the following:
systemBoard(1)
General
processor(2)
Processor
memory(3)
… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.4 |
| cpqHePowerFailureDeviceBitMap mandatory The hex representation of the device(s) within the specified area. | column | Integer32 | .1.3.6.1.4.1.232.6.2.20.2.1.5 |
| cpqHePowerFailureGroupString mandatory The location of the device on the system board. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.6.2.20.2.1.6 |
| cpqHePowerFailureRepairSteps mandatory Recommended troubleshooting steps for a particular device error.
The value will be one of the following:
noError(1)
No errors were detected at this time.
… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.7 |
| cpqHePowerFailureType mandatory Critical power failure that occurred.
The value will be one of the following:
noError(1)
No error has occurred.
tempDeadly(2)
The server was shut d… | column | Enumeration | .1.3.6.1.4.1.232.6.2.20.2.1.8 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| RFC1213-MIBsysName mandatory An administratively-assigned name for this
managed node. By convention, this is the node's
fully-qualified domain name. | scalar | OctetString | .1.3.6.1.2.1.1.5 |
| CPQHOST-MIBcpqHoTrapFlags mandatory The Trap Flags.
This is a collection of flags used during trap delivery.
Each bit has the following meaning:
Bit 5-31: RESERVED: Always 0.
… | scalar | Integer32 | .1.3.6.1.4.1.232.11.2.11.1 |
| cpqHeResMemBoardIndex mandatory The slot in which the memory board or cartridge is installed.
A value of 0 indicates memory installed directly on the
system board. | column | Integer32 | .1.3.6.1.4.1.232.6.2.14.11.1.1 |
| cpqHeResMemModuleIndex mandatory The memory module number. | column | Integer32 | .1.3.6.1.4.1.232.6.2.14.11.1.2 |
| cpqHeResMemModuleSparePartNo mandatory The memory module's manufacturer part number.
This field will be a null (size 0) string if the manufacturer
part number is not available. | column | OctetString | .1.3.6.1.4.1.232.6.2.14.11.1.3 |
| CPQSINFO-MIBcpqSiMemModuleSize mandatory Module memory size in kilobytes. A kilobyte of memory is
defined as 1024 bytes.
A size of 0 indicates the module is not present. | column | Integer32 | .1.3.6.1.4.1.232.2.2.4.5.1.3 |
| CPQSINFO-MIBcpqSiServerSystemId mandatory A Server System ID.
This value is used to uniquely identify systems via a unique
ID on systems that do not support the EISA bus. | scalar | OctetString | .1.3.6.1.4.1.232.2.2.4.17 |