cpqHeOsCommonPollFreq

CPQHLTH-MIB · .1.3.6.1.4.1.232.6.2.1.4.1

Object

scalar mandatory r/w Integer32
The Insight Agent's polling frequency.
          
The frequency, in seconds, at which the Insight Agent requests
information from the device driver.  A frequency of zero
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
          
If the poll frequency is 0 all attempts to write to this
object will fail.  If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent.  Setting the poll frequency to zero will always
fail, an agent may also choose to fail any request to change
the poll frequency to a value that would severely impact system
performance.

Context

MIB
CPQHLTH-MIB
OID
.1.3.6.1.4.1.232.6.2.1.4.1
Type
scalar
Access
readwrite
Status
mandatory
Parent
cpqHeOsCommon
Siblings
1

Syntax

Integer32

Values & Constraints

No enumerated values or constraints recorded.