cpqHeInterlockFailureType

CPQHLTH-MIB · .1.3.6.1.4.1.232.6.2.21.2.1.6

Object

column mandatory Enumeration
The type of critical Interlock failure that occurred.
The value will be one of the following:
              
noError(1)
 No error has occurred.
              
standby(2)
 The server had a power fault that occurred while it was powered off.
              
runtime(3)
 The server was shut down due to a power fault that occurred while it was powered on.
              
powerOn(4)
 The server had a power fault that occurred while attempting to power on.
              
generic(5)
 The server had a power fault but the reason is unknown.

Context

MIB
CPQHLTH-MIB
OID
.1.3.6.1.4.1.232.6.2.21.2.1.6
Type
column
Access
readonly
Status
mandatory
Parent
cpqHeInterlockFailureTableEntry
Table
cpqHeInterlockFailureTable
Siblings
5

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.