cpqHeHWBiosCondition

CPQHLTH-MIB · .1.3.6.1.4.1.232.6.2.16.1

Object

scalar mandatory Enumeration
This value indicates an error has been detected  during Pre-OS Test (POST) or
during initial hardware initialization. Typically, this will be a hardware interlock
not closed due to an adapter or cable not properly seated in the slot. The first
action is to review the iLO Event Log and iLO Integrated Management Log (IML)
for a new event. If no entries found, the  server will usually require a physical 
inspection to identify the source of the issue by observing the external and 
internal hardware status LEDs.
          
          
This value will be one of the following:
other(1)
There is no data available to support the cpqHeHWBiosCondition.
          
ok(2)
The primary server hardware is operational.
          
degraded(3)
A non-fatal condition detected. Review iLO Event and Integrated Management Logs.
          
failed(4)
A fatal condition detected during POST or prior to hardware power on.

Context

MIB
CPQHLTH-MIB
OID
.1.3.6.1.4.1.232.6.2.16.1
Type
scalar
Access
readonly
Status
mandatory
Parent
cpqHeHWBios

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.