cpqHeFltTolFanHotPlug

CPQHLTH-MIB · .1.3.6.1.4.1.232.6.2.6.7.1.10

Object

column mandatory Enumeration
This indicates if the fan is capable of being removed and/or
inserted while the system is in an operational state.
              
If the value is hotPluggable(3), the fan can be safely
removed if and only if the cpqHeFltTolFanRedundant
field is in a redundant(3) state.
              
This value will be one of the following:
other(1)
  The state could not be determined.
              
nonHotPluggable(2)
  The fan is not hot plug capable.
              
hotPluggable(3)
  The fan is hot plug capable and can be removed if
  the system is operating in a redundant state.  A fan
  may be added to an empty fan bay.

Context

MIB
CPQHLTH-MIB
OID
.1.3.6.1.4.1.232.6.2.6.7.1.10
Type
column
Access
readonly
Status
mandatory
Parent
cpqHeFltTolFanEntry
Table
cpqHeFltTolFanTable
Siblings
11

Syntax

Enumeration

Values & Constraints

No enumerated values or constraints recorded.