cpqHeCoolingModuleHotPlug
CPQHLTH-MIB ·
.1.3.6.1.4.1.232.6.2.6.9.1.10
Object
column
mandatory
Enumeration
This indicates if the Cooling Module is capable of being removed and/or
inserted while the system is in an operational state.
If the value is hotPluggable(3), the Cooling module can be safely
removed if and only if the cpqHeCoolingRedundant field is in a redundant(3) state.
This value will be one of the following:
other(1)
The state could not be determined.
nonHotPluggable(2)
The Cooling Module is not hot plug capable.
hotPluggable(3)
The Cooling module is hot plug capable and can be removed if the system
is operating in a redundant state. A Cooling module may be added to an empty bay.
Context
- MIB
- CPQHLTH-MIB
- OID
.1.3.6.1.4.1.232.6.2.6.9.1.10- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqHeCoolingModuleEntry
Syntax
Enumeration
Values & Constraints
Object Constraints
range: 0-255