cpqHeBbuTimeToCutoff
CPQHLTH-MIB ·
.1.3.6.1.4.1.232.6.2.23.2.1.4
Object
column
mandatory
Integer32
Run time (in seconds) available with the battery backup unit until cut off. This is detected only when battery is charging or discharging, otherwise set to 0.
Context
- MIB
- CPQHLTH-MIB
- OID
.1.3.6.1.4.1.232.6.2.23.2.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqHeBbuEntry
- Table
- cpqHeBbuTable
- Siblings
- 14
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqHeBbuChassis mandatory The system chassis number. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.1 |
| cpqHeBbuChargePercentage mandatory Percentage charge remaining for the battery backup unit. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.10 |
| cpqHeBbuSerialNumber mandatory Serial number of the battery backup unit. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.6.2.23.2.1.11 |
| cpqHeBbuMaxCapacityWatts mandatory Total capacity (in Watts) of the battery backup unit. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.12 |
| cpqHeBbuFirmware mandatory Firmware version of the battery backup unit. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.6.2.23.2.1.13 |
| cpqHeBbuChargeState mandatory Charge state of the battery backup unit. | column | Enumeration | .1.3.6.1.4.1.232.6.2.23.2.1.14 |
| cpqHeBbuErrorCondition mandatory The error condition of the battery backup unit. | column | Enumeration | .1.3.6.1.4.1.232.6.2.23.2.1.15 |
| cpqHeBbuBay mandatory The bay number to index within this chassis. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.2 |
| cpqHeBbuStatus mandatory Indicates status of the bbu.
The following values are defined:
unknown(1)
Not able to determine the battery status
ok(2)
Battery status is fine
… | column | Enumeration | .1.3.6.1.4.1.232.6.2.23.2.1.3 |
| cpqHeBbuTimeToCharge mandatory Time required (in minutes) to fully charge the battery backup unit. This is detected only when battery is charging or discharging, otherwise set to 0. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.5 |
| cpqHeBbuRatedCapacity mandatory Rated capacity (mAh) of the battery backup unit. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.6 |
| cpqHeBbuPresentCapacity mandatory Present capacity (mAh) of the battery backup unit. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.7 |
| cpqHeBbuCutoffCapacity mandatory Cutoff capacity (mAh) of the battery backup unit. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.8 |
| cpqHeBbuCutoffSetPoint mandatory Cutoff threshold (mAh) defined by firmware required to complete operations. | column | Integer32 | .1.3.6.1.4.1.232.6.2.23.2.1.9 |
Notification Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| RFC1213-MIBsysName mandatory An administratively-assigned name for this
managed node. By convention, this is the node's
fully-qualified domain name. | scalar | OctetString | .1.3.6.1.2.1.1.5 |
| CPQHOST-MIBcpqHoTrapFlags mandatory The Trap Flags.
This is a collection of flags used during trap delivery.
Each bit has the following meaning:
Bit 5-31: RESERVED: Always 0.
… | scalar | Integer32 | .1.3.6.1.4.1.232.11.2.11.1 |