cpqFcaSpareLocationString
CPQFCA-MIB ·
.1.3.6.1.4.1.232.16.2.4.1.1.10
Object
column
mandatory
OctetString
Spare Drive Location String.
This string describes the location of the drive in relation to
the storage box. If the location string cannot be determined,
the agent will return a NULL string.
Context
- MIB
- CPQFCA-MIB
- OID
.1.3.6.1.4.1.232.16.2.4.1.1.10- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- cpqFcaSpareEntry
- Table
- cpqFcaSpareTable
- Siblings
- 9
Syntax
OctetString
Values & Constraints
Object Constraints
range: 0-255
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqFcaSpareBoxIndex mandatory External Array Spare Drive Storage Box Index.
The storage box index indicates which storage box this spare
drive is in. | column | Integer32 | .1.3.6.1.4.1.232.16.2.4.1.1.1 |
| cpqFcaSparePhyDrvIndex mandatory External Array Spare Physical Drive Index.
This index maps the spare to the physical drive it represents.
The value of this index is the same as the one used with t… | column | Integer32 | .1.3.6.1.4.1.232.16.2.4.1.1.2 |
| cpqFcaSpareStatus mandatory Spare Status.
This shows the status of the on-line spare drive.
The following values are valid for the spare status:
Inactive (2)
Th… | column | Enumeration | .1.3.6.1.4.1.232.16.2.4.1.1.3 |
| cpqFcaSpareReplacedDrvBay mandatory Spare Replaced Drive Bay.
If the spare status is active(6) or building(5), then this
has the physical drive bay number of the replaced drive.
If the value cannot be… | column | Integer32 | .1.3.6.1.4.1.232.16.2.4.1.1.4 |
| cpqFcaSparePercentRebuild mandatory External Array Spare Percent Rebuild.
If the spare status is building(5), then this is percent
complete of of the rebuild.
The data contained on the … | column | RFC1155-SMIGauge | .1.3.6.1.4.1.232.16.2.4.1.1.5 |
| cpqFcaSpareCondition mandatory The Spare Drive condition.
This value represents the overall condition of this spare drive
and any associated physical drives. | column | Enumeration | .1.3.6.1.4.1.232.16.2.4.1.1.6 |
| cpqFcaSpareBusNumber mandatory Spare Drive SCSI Bus Number.
The bus number indicates to which SCSI bus this spare drive
is attached. The first instance is one and increments
for each SCSI bus on… | column | Integer32 | .1.3.6.1.4.1.232.16.2.4.1.1.7 |
| cpqFcaSpareBay mandatory External Array Spare Drive Bay Location.
This value matches the bay location where the physical drive has
been installed. Each bay is labeled with a separate numbe… | column | Integer32 | .1.3.6.1.4.1.232.16.2.4.1.1.8 |
| cpqFcaSpareReplacedDrvBusNumber mandatory Spare Replaced Drive Bus Number.
If the spare status is active(6) or building(5), then this
has the physical drive bus number of the replaced drive.
If the value ca… | column | Integer32 | .1.3.6.1.4.1.232.16.2.4.1.1.9 |