cpqCmcSetupSmoke
CPQCMC-MIB ·
.1.3.6.1.4.1.232.153.2.2.2.1.2.13
Object
node
No description available.
Context
- MIB
- CPQCMC-MIB
- OID
.1.3.6.1.4.1.232.153.2.2.2.1.2.13- Type
- node
- Parent
- cpqCmcSetupEvents
- Siblings
- 17
- Children
- 5
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCmcSetupTemp1 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.1 |
| cpqCmcSetupInput4 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.10 |
| cpqCmcSetupLock1 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.11 |
| cpqCmcSetupLock2 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.12 |
| cpqCmcSetupShock | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.14 |
| cpqCmcSetupAux1 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.15 |
| cpqCmcSetupAux2 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.16 |
| cpqCmcSetupAlarm1 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.17 |
| cpqCmcSetupAlarm2 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.18 |
| cpqCmcSetupTemp2 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.2 |
| cpqCmcSetupFan1 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.3 |
| cpqCmcSetupFan2 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.4 |
| cpqCmcSetupVoltage | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.5 |
| cpqCmcSetupHumidity | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.6 |
| cpqCmcSetupInput1 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.7 |
| cpqCmcSetupInput2 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.8 |
| cpqCmcSetupInput3 | node | - | .1.3.6.1.4.1.232.153.2.2.2.1.2.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCmcSetupSmokeAvail mandatory Smoke sensor:
(2) available
(3) not available | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.13.1 |
| cpqCmcSetupSmokeRelays mandatory Alert handling of Alarm Relays in case of an alarm condition
of Smoke Sensor:
(2) no switching of Relays
(3) Relay 1 will switch
(4) Relay 2 will switch
(5) both Relays will switch | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.13.2 |
| cpqCmcSetupSmokeAudibleAlarm mandatory Alert handling of Audible Alarm of in case of an alarm condition
of Smoke Sensor:
(2) Start Audible Alarm
(3) No Audible Alarm | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.13.3 |
| cpqCmcSetupSmokeFansOff mandatory Fan switching off if in case of smoke-alarm:
(2) both fans would be switched off
(3) only fan1 will be switched off
(4) only fan2 will be switched off
(5) no fan will be switched … | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.13.4 |
| cpqCmcSetupSmokeUnlock mandatory Lock is unlocked in case of smoke-alarm:
(2) both locks will be unlocked
(3) only lock1 will be unlocked
(4) only lock2 will be unlocked
(5) no lock will be unlocked | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.13.5 |