cpqCmcSetupLock2RelaysDevice
CPQCMC-MIB ·
.1.3.6.1.4.1.232.153.2.2.2.1.2.12.3
Object
scalar
mandatory
r/w
Enumeration
Alert handling of Alarm Relays in case of an alarm condition of Locking device 2 (power fail, low battery...): (2) no switching of Relays (3) Relay 1 will switch (4) Relay 2 will switch (5) both Relays will switch
Context
- MIB
- CPQCMC-MIB
- OID
.1.3.6.1.4.1.232.153.2.2.2.1.2.12.3- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- cpqCmcSetupLock2
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | other |
2 | off |
3 | relay1 |
4 | relay2 |
5 | both |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCmcSetupLock2Avail mandatory Door locking device 2:
(2) device available
(3) device not available, no alarm, if door is not locked | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.1 |
| cpqCmcSetupLock2LifeFailUnlock mandatory Unlock door in case of lifecheck failure (connection CMC<->locking device):
(2) disabled
(3) auto unlock the door
(4) unlock door with remote signal | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.10 |
| cpqCmcSetupLock2Relays mandatory Alert handling of Alarm Relays in case of an alarm condition
of Lock 2 (door not locked..):
(2) no switching of Relays
(3) Relay 1 will switch
(4) Relay 2 will switch
(5) both Rel… | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.2 |
| cpqCmcSetupLock2AudibleAlarm mandatory Alert handling of Audible Alarm of in case of an alarm condition
of Lock 2:
(2) Start Audible Alarm
(3) No Audible Alarm | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.4 |
| cpqCmcSetupLock2AudibleAlarmDevice mandatory Alert handling of Audible Alarm of in case of an alarm condition
of Locking device 2 (power fail, low battery..):
(2) Start Audible Alarm
(3) No Audible Alarm | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.5 |
| cpqCmcSetupLock2Time mandatory Time in seconds while the lock 2 is unlocked
after getting an unlock-command | scalar | Integer32 | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.6 |
| cpqCmcSetupLock2PwrFailUnlock mandatory Unlock door in case of power fail of locking device:
(2) disabled
(3) auto unlock the door
(4) unlock door with remote signal | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.7 |
| cpqCmcSetupLock2BattLowUnlock mandatory Unlock door in case of low battery of locking device:
(2) disabled
(3) auto unlock the door
(4) unlock door with remote signal | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.8 |
| cpqCmcSetupLock2NetFailUnlock mandatory Unlock door in case of network failure:
(2) disabled
(3) auto unlock the door
(4) unlock door with remote signal | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.2.1.2.12.9 |