cpqCmcControl
CPQCMC-MIB ·
.1.3.6.1.4.1.232.153.2.2.5
Object
node
No description available.
Context
- MIB
- CPQCMC-MIB
- OID
.1.3.6.1.4.1.232.153.2.2.5- Type
- node
- Parent
- cpqCmcDevice
- Siblings
- 5
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCmcDeviceCondition mandatory Condition of CMC device,
(3) an overload of the 24V DC supply to the connected accessories occurred
(4) the overload-protection (fuse) has released | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.1 |
| cpqCmcSetup | node | - | .1.3.6.1.4.1.232.153.2.2.2 |
| cpqCmcValues | node | - | .1.3.6.1.4.1.232.153.2.2.3 |
| cpqCmcStatus | node | - | .1.3.6.1.4.1.232.153.2.2.4 |
| cpqCmcLog | node | - | .1.3.6.1.4.1.232.153.2.2.6 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cpqCmcStatusAccess mandatory Status access, for future use | scalar | OctetString | .1.3.6.1.4.1.232.153.2.2.5.1 |
| cpqCmcSetFan2 mandatory Is used for run and stop control of fan2.
(2) fan will run and stop according to temperature of sensor 2
and threshold of fan2
(3) fan will run independent of temperature and … | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.10 |
| cpqCmcSetQuitRelay1 mandatory Status and quit of alarm relay 1.
(2) relay is switched because of an alarm
(3) relay is not switched, no alarm
(4) (set) will quit relay 1 in case of alarm | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.11 |
| cpqCmcSetQuitRelay2 mandatory Status and quit of alarm relay 2.
(2) relay is switched because of an alarm
(3) relay is not switched, no alarm
(4) (set) will quit relay 2 in case of alarm | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.12 |
| cpqCmcSetLock1Lock mandatory Set door locking device 1, see table
With this command the management-station can set the conditions for
the door locking device
(2) Door will be locked
(3) Door will be unlocked … | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.2 |
| cpqCmcSetLock1Key mandatory Enable or disable unlocking of the rack-door with external components
like keypad or remote input.
With this command the management station can set the conditions for
unlocking th… | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.3 |
| cpqCmcSetLock2Lock mandatory Set door locking device 2, see table
With this command the management-station can set the conditions for
the door locking device
(2) Door will be locked
(3) Door will be unlocked … | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.4 |
| cpqCmcSetLock2Key mandatory Enable or disable unlocking of the rack-door with external components
like keypad or remote input.
With this command the management-station can set the conditions for
unlocking th… | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.5 |
| cpqCmcSetMessage mandatory Set message to CMC, for future use | scalar | OctetString | .1.3.6.1.4.1.232.153.2.2.5.6 |
| cpqCmcSetAlarm1 mandatory Is used to set an alarm in the CMC from the management-station.
With this command the management-station can i.e. switch on an
alarm-relay or the AudibleAlarm of the CMC.
Can be u… | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.7 |
| cpqCmcSetAlarm2 mandatory Is used to set an alarm in the CMC from the management-station.
With this command the management-station can i.e. switch on an
alarm-relay or the AudibleAlarm of the CMC.
Can be u… | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.8 |
| cpqCmcSetFan1 mandatory Is used for run and stop control of fan1.
(2) fan will run and stop according to temperature of sensor 1
and threshold of fan1
(3) fan will run independent of temperature and … | scalar | Enumeration | .1.3.6.1.4.1.232.153.2.2.5.9 |