pluggableRequiredType
CORIANT-GROOVE-MIB ·
.1.3.6.1.4.1.42229.1.2.3.8.1.1.1
Object
column
CoriantTypesPluggableType
The attribute indicates the equipment type to identify the module. Needs to be re-defined in the project specific model.
Context
- MIB
- CORIANT-GROOVE-MIB
- OID
.1.3.6.1.4.1.42229.1.2.3.8.1.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pluggableEntry
- Table
- pluggableTable
- Siblings
- 16
Syntax
CoriantTypesPluggableType
- Source
- CoriantTypesPluggableType
- Base type
Enumeration
Values & Constraints
Type Values
20 | nonPluggable |
21 | qsfp |
22 | cfp2 |
23 | sfpplus |
24 | sfp |
25 | cfp2Dco |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pluggableClei Identifies the CLEI code number of the equipment.
The CLEI code is a 10-character code that identifies
communications equipment. It describes product type, features,
source docum… | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.10 |
| pluggableEquipmentName The attribute indicates an additional field to identify the module. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.11 |
| pluggableAdminStatus The administrative state specifies the permission to use or prohibition
against using the resource. The administrative state can be modified by the user, and operates independent… | column | Enumeration | .1.3.6.1.4.1.42229.1.2.3.8.1.1.12 |
| pluggableOperStatus The operational state specifies whether or not a resource is able to provide service.
The operational state shall be visible to the operator. The user cannot modify the operation… | column | Enumeration | .1.3.6.1.4.1.42229.1.2.3.8.1.1.13 |
| pluggableAvailStatus Provided to qualify the operational, usage and/or administrative status attributes.
The value shall be a bits, management interface shall show the string with space separator ' '… | column | Bits | .1.3.6.1.4.1.42229.1.2.3.8.1.1.14 |
| pluggableAliasName User defined alias for this entity. Must be an alphanumeric string with dash or underscore | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.15 |
| pluggableTemperature Temperature at the monitoring point. | column | CoriantTypesTemperature | .1.3.6.1.4.1.42229.1.2.3.8.1.1.16 |
| pluggableVoltage The current voltage applied by the module. The current is
expressed in V with up to two decimal precision. Just
supply the instant value.
UNITS:V | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.17 |
| pluggableFormFactor Indicating the exact form factor of the pluggable.
default value :Unrecognized | column | CoriantTypesPluggableFormFactor | .1.3.6.1.4.1.42229.1.2.3.8.1.1.2 |
| pluggableInterfaceType Indicating interface type of the pluggable.
default value : | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.3 |
| pluggableLaserSource The type of laser frequency. Only tx-lo-independent type support och-os rx-frequency working
Conditions:../required-type = 'CFP2'
default value :n… | column | Enumeration | .1.3.6.1.4.1.42229.1.2.3.8.1.1.4 |
| pluggableHwVersion The attribute Identifies the Hardware Version of the module that populates the slot. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.5 |
| pluggableVendor Vendor information. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.6 |
| pluggableSerialNumber This is the value of serial number stored in EEPROM of the equipment. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.7 |
| pluggableFwVersion Current Firmware (FW) version on the equipment. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.8 |
| pluggablePartNumber Identifies the Part Number of the equipment. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.9 |