pluggableAdminStatus
CORIANT-GROOVE-MIB ·
.1.3.6.1.4.1.42229.1.2.3.8.1.1.12
Object
column
Enumeration
The administrative state specifies the permission to use or prohibition
against using the resource. The administrative state can be modified by the user, and operates independently of the operability and usage of the resource.
default value :up
Context
- MIB
- CORIANT-GROOVE-MIB
- OID
.1.3.6.1.4.1.42229.1.2.3.8.1.1.12- Type
- column
- Access
- readonly
- Status
- current
- Parent
- pluggableEntry
- Table
- pluggableTable
- Siblings
- 16
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | up |
2 | down |
3 | upNoAlm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| pluggableRequiredType The attribute indicates the equipment type to identify the module.
Needs to be re-defined in the project specific model. | column | CoriantTypesPluggableType | .1.3.6.1.4.1.42229.1.2.3.8.1.1.1 |
| pluggableClei Identifies the CLEI code number of the equipment.
The CLEI code is a 10-character code that identifies
communications equipment. It describes product type, features,
source docum… | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.10 |
| pluggableEquipmentName The attribute indicates an additional field to identify the module. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.11 |
| pluggableOperStatus The operational state specifies whether or not a resource is able to provide service.
The operational state shall be visible to the operator. The user cannot modify the operation… | column | Enumeration | .1.3.6.1.4.1.42229.1.2.3.8.1.1.13 |
| pluggableAvailStatus Provided to qualify the operational, usage and/or administrative status attributes.
The value shall be a bits, management interface shall show the string with space separator ' '… | column | Bits | .1.3.6.1.4.1.42229.1.2.3.8.1.1.14 |
| pluggableAliasName User defined alias for this entity. Must be an alphanumeric string with dash or underscore | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.15 |
| pluggableTemperature Temperature at the monitoring point. | column | CoriantTypesTemperature | .1.3.6.1.4.1.42229.1.2.3.8.1.1.16 |
| pluggableVoltage The current voltage applied by the module. The current is
expressed in V with up to two decimal precision. Just
supply the instant value.
UNITS:V | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.17 |
| pluggableFormFactor Indicating the exact form factor of the pluggable.
default value :Unrecognized | column | CoriantTypesPluggableFormFactor | .1.3.6.1.4.1.42229.1.2.3.8.1.1.2 |
| pluggableInterfaceType Indicating interface type of the pluggable.
default value : | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.3 |
| pluggableLaserSource The type of laser frequency. Only tx-lo-independent type support och-os rx-frequency working
Conditions:../required-type = 'CFP2'
default value :n… | column | Enumeration | .1.3.6.1.4.1.42229.1.2.3.8.1.1.4 |
| pluggableHwVersion The attribute Identifies the Hardware Version of the module that populates the slot. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.5 |
| pluggableVendor Vendor information. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.6 |
| pluggableSerialNumber This is the value of serial number stored in EEPROM of the equipment. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.7 |
| pluggableFwVersion Current Firmware (FW) version on the equipment. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.8 |
| pluggablePartNumber Identifies the Part Number of the equipment. | column | OctetString | .1.3.6.1.4.1.42229.1.2.3.8.1.1.9 |