chHWPowerActive
CONFIG-MIB ·
.1.3.6.1.4.1.81.7.11.6.1.1.4
Object
column
mandatory
Enumeration
This object has a value of yes(1) if the module
installed in this slot is powered up.
This object has a value of no(2) when the module is
powered down or the slot is empty.
Context
- MIB
- CONFIG-MIB
- OID
.1.3.6.1.4.1.81.7.11.6.1.1.4- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- chHWPowerEntry
- Table
- chHWPowerTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | yes |
2 | no |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| chHWPowerSlotId mandatory Index, which identifies the slot inside the chassis
for which this entry contains information.
The number of entries in this table is equal to
chNumberOfSlots. | column | Integer32 | .1.3.6.1.4.1.81.7.11.6.1.1.1 |
| chHWPowerPoEDemand mandatory This parameter indicates the PoE power consumption
in milliwatts for this module. | column | Integer32 | .1.3.6.1.4.1.81.7.11.6.1.1.10 |
| chHWPowerModType mandatory Attribute describing the type of the module.
Values in this attribute are the same as genGroupType
but applicable also for un-powered modules and empty
slots. | column | Enumeration | .1.3.6.1.4.1.81.7.11.6.1.1.2 |
| chHWPowerModTypeName mandatory String with the module name the same as
genGroupTypeName but applicable also for
un-powered modules and empty slots. | column | OctetString | .1.3.6.1.4.1.81.7.11.6.1.1.3 |
| chHWPowerEnable mandatory Setting the value of this attribute to enable(1)
enables the power for this slot.
When this attribute is set to disable(2),
the power for this slot is disabled. | column | Enumeration | .1.3.6.1.4.1.81.7.11.6.1.1.5 |
| chHWPowerHistory mandatory This object has a value of yes(1) if the module
installed in this slot has power history.
This object has a value of no(2) when the module has not
power history.
… | column | Enumeration | .1.3.6.1.4.1.81.7.11.6.1.1.6 |
| chHWPowerDemand mandatory Indicates total electrical power consumption for the
module installed in this slot expressed in milliWatts.
Returns zero if the slot is empty. | column | Integer32 | .1.3.6.1.4.1.81.7.11.6.1.1.7 |
| chHWPowerPriority mandatory This parameter controls the powering priority of the module
and is used by power budget management algorithm. | column | Enumeration | .1.3.6.1.4.1.81.7.11.6.1.1.8 |
| chHWPowerPoEBudget mandatory This parameter indicates the PoE budget in milliwatts
allocated for this module. | column | Integer32 | .1.3.6.1.4.1.81.7.11.6.1.1.9 |