temperatureThresholdBladeName
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5
Object
column
mandatory
OctetString
The name of the blade as a null terminated string.
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.5- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- bladeTemperatureThresholdsEntry
- Table
- bladeTemperatureThresholdsTable
- Siblings
- 47
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| temperatureThresholdIndex mandatory Blade temperature threshold table index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.1 |
| temperatureCPU2Warning mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.10 |
| temperatureCPU2WarningReset mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
aler… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.11 |
| temperatureCPU3HardShutdown mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.12 |
| temperatureCPU3Warning mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.13 |
| temperatureCPU3WarningReset mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
aler… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.14 |
| temperatureCPU4HardShutdown mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.15 |
| temperatureCPU4Warning mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.16 |
| temperatureCPU4WarningReset mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
aler… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.17 |
| temperatureDASD1HardShutdown mandatory The blade DASD hard shutdown temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for posi… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.18 |
| temperatureDASD1Warning mandatory The blade DASD warning temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.19 |
| temperatureThresholdBladeId mandatory The numeric blade ID. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.2 |
| temperatureDASD1WarningReset mandatory The blade DASD warning reset temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for posi… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.20 |
| bladeTempThresholdSensorCapability mandatory Indicates whether the server blade is IPMI capable or not. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.21 |
| temperatureSensor1HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.22 |
| temperatureSensor1Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.23 |
| temperatureSensor1WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.24 |
| temperatureSensor2HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.25 |
| temperatureSensor2Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.26 |
| temperatureSensor2WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.27 |
| temperatureSensor3HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.28 |
| temperatureSensor3Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.29 |
| temperatureThresholdBladeExists mandatory Indicates whether the server blade specified exists or not. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.3 |
| temperatureSensor3WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.30 |
| temperatureSensor4HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.31 |
| temperatureSensor4Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.32 |
| temperatureSensor4WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.33 |
| temperatureSensor5HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.34 |
| temperatureSensor5Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.35 |
| temperatureSensor5WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.36 |
| temperatureSensor6HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.37 |
| temperatureSensor6Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.38 |
| temperatureSensor6WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.39 |
| temperatureThresholdBladePowerState mandatory Indicates the power state of the blade specified. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.4 |
| temperatureSensor7HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.40 |
| temperatureSensor7Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.41 |
| temperatureSensor7WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.42 |
| temperatureSensor8HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.43 |
| temperatureSensor8Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.44 |
| temperatureSensor8WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.45 |
| temperatureSensor9HardShutdown mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.46 |
| temperatureSensor9Warning mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.47 |
| temperatureSensor9WarningReset mandatory The blade hard shutdown temperature for IPMI blades in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank spa… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.48 |
| temperatureCPU1HardShutdown mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.
If enabled, a … | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.6 |
| temperatureCPU1Warning mandatory The blade CPU warning temperature in degrees centigrade(C).
If the temperature rises above this value a warning alert/event
if enabled will be generated.
An octet string expressed… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.7 |
| temperatureCPU1WarningReset mandatory The blade CPU warning reset temperature in degrees
centigrade(C). If the temperature rises above this value and
if a warning alert/event had previously been created then the
aler… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.4.1.8 |
| temperatureCPU2HardShutdown mandatory The blade CPU hard shutdown temperature in degrees
centigrade(C). If the component's temperature rises above
this value the system will be powered off immediately.