temperatureCPU1
CME-MIB ·
.1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6
Object
column
mandatory
OctetString
The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a decimal digit or blank space for leading zeroes.
The string 'Not Readable!' indicates that the given monitor
is not supported on this system.
The string 'No Temperature' indicates that the given monitor
does not exist on this system or is powered off.
Context
- MIB
- CME-MIB
- OID
.1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.6- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- bladeTemperaturesEntry
- Table
- bladeTemperaturesTable
- Siblings
- 19
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| temperatureIndex mandatory Blade temperatures table index. | column | Integer32 | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.1 |
| temperatureDASD1 mandatory The blade DASD temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a d… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.10 |
| bladeSensorTempCapability mandatory Indicates whether the server blade is IPMI capable or not. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.11 |
| bladeSensor1Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.12 |
| bladeSensor2Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.13 |
| bladeSensor3Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.14 |
| bladeSensor4Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.15 |
| bladeSensor5Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.16 |
| bladeSensor6Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.17 |
| bladeSensor7Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.18 |
| bladeSensor8Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.19 |
| temperatureBladeId mandatory The numeric blade ID. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.2 |
| bladeSensor9Temp mandatory Temperature reading for an IPMI blade expressed in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space f… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.20 |
| temperatureBladeExists mandatory Indicates whether the server blade specified exists or not. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.3 |
| temperatureBladePowerState mandatory Indicates the power state of the blade specified. | column | Enumeration | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.4 |
| temperatureBladeName mandatory The name of the blade as a null terminated string. | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.5 |
| temperatureCPU2 mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a de… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.7 |
| temperatureCPU3 mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a de… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.8 |
| temperatureCPU4 mandatory The blade CPU temperature in degrees centigrade(C).
An octet string expressed as 'sddd.dd Centigrade' where:
s is the sign ('-' for negative or blank space for positive)
d is a de… | column | OctetString | .1.3.6.1.4.1.2.3.51.2.22.1.5.3.1.9 |